Office of Community and Economic Development
17 December 1986
Mr. & Mrs. Donald J, Zadoff
2:175 University Street
Eugene, Oregon 97403
Subject: Fire damage at 540 Flamingo, Springfield, Oregon
Dear Mr. & Mrs Zadoff:
At the request of the Springfield Fire and Life Safety Department, the Building
Safety Division recently conducted an inspection of the fire damage at the above
address. The inspection revealed damage which must be corrected in order for
the building to comply with applicable City codes. Potentially hazardous condi-
tions now exist, due to the fire, which preclude the affected areas from continu-
ing to be occupied.
The following items must be corrected before the building can be reoccupied:
Structural
1. The attached shop was damaged to the extent that the structure is hazard-
ous, and must be provided with temporary structural support, and be
adequately secured to prevent potential injury to inquisitive children. As an
alternative to temporary support, the remaining shop structure may be razed
to the ground. In either case, steps should be taken immediately to reduce
the existing hazard,
2. The east two-thirds of the roof structure has been sufficiently damaged to
require replacement of the structure, including sheathing and roof covering,
3. Ceiling joists over the east half of the living room must be reinforced with
additional joists or replaced.
4. Wall and ceiling coverings throughout the structure were sufficiently
damaged by the fire and water to warrant total ,'eplacement.
5. The subfloor at the front corner of the living room must be replaced where
damaged.
6. Siding and ceiling covering at the porch and siding outside the living room,
kitchen and the den require replacement.
~1~liillD'Yl.~~tfi~~'tJ:~~"iIJiJ,$;;" ""'lli"~~r '~,}I\ ""'...."*~II"'...!JIII!W'...,.."...~Bit:
225 North 5th Street Springfield. Oregon 97477 503/726-3753 (I
,
.
.
Mr. & Mrs. Zadoff
December 17, 1986
Page 2
Electrical
7. All damaged wIrmg and equipment must be replaced or repaired in compli-
ance with applicable code requirements,
Plumbing
8. The plumbing system is not operational. Components of the system and
plumbing fixtures which were damaged by the fire shall be ,'eplaced, Such
components shall conform to the requirements for new plumbing systems or
plumbing fixtures mandated by the O'"egon State Plumbing Specialty Code.
You may elect to repair, rebuild or demolish the structure, in order to comply
with the City code requirements for hazardous buildings, Permits and inspections
are required for any of these options, and may be obtained from this office prior
to commencing work. If you elect to ,'ebuild or remodel the structure, please
submit two cmopletc sets of plans for our review when application for permits is
made,
If we can be of assistance in clarifying the requirements, or the options
available to bring the building into compliance, please call us at 726-3759,
Sincerely,
1
4~ }7~~
Don Moore
Struct. Inspector
I~'" I;rl,.::dz~
Jim Matteson
Elect. Inspector
/7 ,; t?,'/
:>)' c.jW:'/4?l-~cr-
Ralph Shaw
Plumb/Mech, Inspector
cc.
Dave Puent, Building Official
Mike Hudman, Fire Marshal