Loading...
HomeMy WebLinkAboutBuilding Correspondence 1986-12-17 . . SPRINGFIELD / CITY OF SPRINGFIELD , ' , I. ,hOc.' I.lhl I....!.l,,' o,LI"" "....."'....'Iii~! """'.jjjIJ.._.,_,dJ ~1~rMII",~~CUl*~'" ml1jiu~lIotli.,.., ..u.W'lt:IiI.w"" ~"a:MCIllI M.....JlIl-...:::.ul.t1.~...li!iII!IIIW_13~......iI..J. ~ i.&lJ a ,. I. u-.:r'. I" Office of Community and Economic Development 17 December 1986 Mr. & Mrs. Donald J, Zadoff 2:175 University Street Eugene, Oregon 97403 Subject: Fire damage at 540 Flamingo, Springfield, Oregon Dear Mr. & Mrs Zadoff: At the request of the Springfield Fire and Life Safety Department, the Building Safety Division recently conducted an inspection of the fire damage at the above address. The inspection revealed damage which must be corrected in order for the building to comply with applicable City codes. Potentially hazardous condi- tions now exist, due to the fire, which preclude the affected areas from continu- ing to be occupied. The following items must be corrected before the building can be reoccupied: Structural 1. The attached shop was damaged to the extent that the structure is hazard- ous, and must be provided with temporary structural support, and be adequately secured to prevent potential injury to inquisitive children. As an alternative to temporary support, the remaining shop structure may be razed to the ground. In either case, steps should be taken immediately to reduce the existing hazard, 2. The east two-thirds of the roof structure has been sufficiently damaged to require replacement of the structure, including sheathing and roof covering, 3. Ceiling joists over the east half of the living room must be reinforced with additional joists or replaced. 4. Wall and ceiling coverings throughout the structure were sufficiently damaged by the fire and water to warrant total ,'eplacement. 5. The subfloor at the front corner of the living room must be replaced where damaged. 6. Siding and ceiling covering at the porch and siding outside the living room, kitchen and the den require replacement. ~1~liillD'Yl.~~tfi~~'tJ:~~"iIJiJ,$;;" ""'lli"~~r '~,}I\ ""'...."*~II"'...!JIII!W'...,.."...~Bit: 225 North 5th Street Springfield. Oregon 97477 503/726-3753 (I , . . Mr. & Mrs. Zadoff December 17, 1986 Page 2 Electrical 7. All damaged wIrmg and equipment must be replaced or repaired in compli- ance with applicable code requirements, Plumbing 8. The plumbing system is not operational. Components of the system and plumbing fixtures which were damaged by the fire shall be ,'eplaced, Such components shall conform to the requirements for new plumbing systems or plumbing fixtures mandated by the O'"egon State Plumbing Specialty Code. You may elect to repair, rebuild or demolish the structure, in order to comply with the City code requirements for hazardous buildings, Permits and inspections are required for any of these options, and may be obtained from this office prior to commencing work. If you elect to ,'ebuild or remodel the structure, please submit two cmopletc sets of plans for our review when application for permits is made, If we can be of assistance in clarifying the requirements, or the options available to bring the building into compliance, please call us at 726-3759, Sincerely, 1 4~ }7~~ Don Moore Struct. Inspector I~'" I;rl,.::dz~ Jim Matteson Elect. Inspector /7 ,; t?,'/ :>)' c.jW:'/4?l-~cr- Ralph Shaw Plumb/Mech, Inspector cc. Dave Puent, Building Official Mike Hudman, Fire Marshal