Loading...
HomeMy WebLinkAboutPermit Building 2007-7-19 Status Issued CITY OF SPRI~(Jl'lELD - Building/Combination Permit PERMIT NO: COM2006-01282 ISSUED: 07/19/2007 APPLIED: 10/09/2006 EXPIRES: 01119/2008 VALUE: $ 800,000.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line SITE ADDRESS: 3000 GATEWAY ST SPACE 540 Springfield ASSESSOR'S PARCEL NO.: 1703220002300 TYPE OF WORK: Restaurant TYPE OF USE: Alteration PROJECT DESCRIPTION: Chuck E Cheese tenant improvement - Gateway Mall Space 540 Commercial Owner: GA TEW A Y MALL PARTNERS Address: 35 CENTURY PARK WAY SALT LAKE CITY UT 84115 Phone Number: 801-486-3911 I CONTRACTOR INFORMATION I Contractor Type Architect General Electrical Mechanical Plumbing Contractor License D SCOTT WINDLE CARTER BURGESS PARKWAY CONSTRUCTION & ASSOClAT 172643 JOHNSEN ELECTRIC INC 38497 HARVEY & PRICE CO 77 HARVEY & PRICE CO 77 BUILDING INFORMATION I Expiration Date 11/06/2010 01/10/2008 10/31/2008 10/3112008 Phone 214-920-8146 972-221-1979 541-461-0291 541-746-1621 541-746-1621 # of Units: Primary Occupancy Group: Secondary Occupancy Group: Primary Construction Type Secondary Construction Type: # of Bedrooms: IIA # of Stories: Height of Structure: Type of Heat: Water Type: Range Type: Energy Path: Sprinkled Building: Lot Size: Sq Ft 1st Floor: Sq Ft 2nd Floor: Sq Ft Basement: Sq Ft Garage/Carport Sq Ft Other: Occupant Load: 425 A-2 n/a I DEVELOPMENT INFORMA nON I REQUIRED PARKING Front yard Setback: Side 1 Setback: Side 2 Setback: Rearyard Setback: Solar Setbacks: Overlay Dist: # Street Trees Rqd: Paved Drive Rqd: % of Lot Coverage: Total: Handicapped: Compact: I PUBLIC IMPROVEMENTS. Street t~~IJC~~Qts: . K Sid Mk~'Wn-P!aw requires you.t,o I ti1~ ~tKIVIII SHALL EXPI~llf ThHirWQR ATTENT,u~vrqv""Tb the Oregon UtlIDiirbside 5' Storm ~mlpJOOI2~~ltJNDER THIS PERMIT 18\1OOT follow rIli16~h~QW*,~~sru\es are'l8tSmt~ Sewer Speciat!m.Jr~~eED OR IS ABANDONED FOR Notification ce~t~~10thrOugh OAR 952-00~- (::unn In OAR 952-00 - . co ias oftha rules Y Notes: ANl(etftJ~~ ~h"'s""~ljuest, to include corrected usage. Primal1()03Qlca'tb~tSl ~flN~tt"~IR~~nt (Pizza) / Tenant Infill.JLP caUing the ~~~ ~~~gon Utility NoUUcaUon " ,: number tor \ 1-8Q0-332-2344). Center S Pal!e 1 of 5 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Description Tvpe of Construction Estimate Estimate Fee Description Plan Review Comm/Ind/Public Plan Review Fire & Life Safety ~Mechanical Issuance Fee~ + 10% Administrative Fee + 5% Technology Fee + 8% State Surcharge Appliance Vent Backflow Device Boiler/Comp 3-15 HP Building Permit Exhaust Hoods Fixture Gas Outlets 1-4 Gas Outlets 4+ Sanitary Sewer - 1st 50 Feet Sanitary Sewer - Improvement Sanitary Sewer - Reimbursement SDC MWMC Administration SDC MWMC Improvement SDC MWMC Reimbursement SDC Sanitary/Storm Admin Vent Fan Total Amount Paid Fire Department Review Initial Review I Valuation Description I $ Per Sq Ft or multiplier $1.00 Square Footage or Bid Amount 800,000.00 Total Value of Project ~ Amount Paid $1,846.42 $1,136.26 $10.00 $341.57 $170.78 $273.25 $6.00 $56.00 $88.00 $2,840.65 $27.00 $336.00 $4.00 $1.00 $45.00 $2,295.64 $3,019.48 $10.00 $49,545.14 $6,197.46 $3,053.39 $12.00 $71,315.04 Date Paid 10/9/06 10/9/06 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 7/19/07 I Plan Reviews I 10/13/2006 12/06/2006 10/10/2006 10/12/2006 OK APP LLH Pal!e 2 of 5 CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2006-01282 ISSUED: 07/19/2007 APPLIED: 10/09/2006 EXPIRES: 01/19/2008 VALUE: $ 800,000.00 Value Date Calculated $800,000.00 $800,000.00 10/09/2006 Receipt Number 3200600000000000527 3200600000000000527 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 3200700000000000485 GRG See attached comments for Fire Department Plans Review comments. CITY OF SPRINGFIELD Building/Combination Permit Status Issued PERMIT NO: COM2006-01282 225 Fifth Street, Springfield, OR ISSUED: 07/19/2007 541-726-3753 Phone APPLIED: 10/09/2006 541-726-3676 Fax EXPIRES: 01119/2008 541-726-3769 Inspection Line VALUE: $ 800,000.00 Plan Review Comments 01/1512006 NOK LLH Page A1.5 received for replacement in original set. Forwarded to John Pearson. 12/15/06 LLH. Note: Content of this transmittal from Carter & Burgess does not contain the documents for this project. Left phone voice-mail message for David Steffen. 2/15/07 dim Plan Review Comments 02116/2007 10 DLM Received response from architect to JMP's plan review comment #1, including 2 copies of Sh. A1.5. One copy forwarded to Fire Marshal. 2/16/07 dim Planninl! Review 10/13/2006 10/19/2006 APP EMM Trees in parking lot islands must NOT be removed. Bicycle Parking rack must NOT be removed. Tree Felling of more than 5 trees 5" in dbh or greater must obtain Tree Felling permit from Planning. Sent letter to Ron Glover on 10/20/06. Public Works Review 11/20/2006 11/15/2006 APP JLP Reviewed @ Ken's request, to include corrected usage. Primary - Arcade & Secondary - Fast Food Restaurant (Pizza) / Tenant Infill.JLP Revised Plan Review - Fir 11/07/2006 12/06/2006 OK GRG See attached document for Fire Department Plans Review comments. The comments includes review of this revision. Revised Plan Review - Fir 02/17/2007 02117/2007 OK GRG Plans Review: Submittal of revised occupant load for proposed Chuck E. Cheese pizza restaurant. Job #COM2006-01282. Occupant load cales per submittal to be 420 seated plus 12 employees. Total occupant load: 432. Revised Plan Review - Pia 11/07/2006 11/08/2006 APP EMM Revised Plan Review - Pu 11/07/2006 11/13/2006 APP CJS Revised Plan Review - no new SDC's. 11113/06 CJS Revised Plan Review - Str 11/07/2006 11/07/2006 10 JMP WE. Received revised drawings from David Steffen with responses to the 22 structural comments. Called David. He will get an egress analysis to satisfy comment 8. He will have the contractor submit the information requested for comments 14, 19, and 20. Structural Review 06/14/2007 06/14/2007 APP JMP Received contractor data and valuation. Pal!e 3 of 5 Status Issued CITY OF SPRINlj.tlELD Building/Combination Permit PERMIT NO: COM2006-01282 ISSUED: 07/19/2007 APPLIED: 10/09/2006 EXPIRES: 01/19/2008 VALUE: $ 800,000.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Structural Review 10/12/2006 10/27/2006 WE JMP See' attached documents for 22 comments faxed to David Scott Windle. SUB Review 11/06/2006 11/06/2006 APP JF SUB Review 10/13/2006 10/30/2006 WE JF Jack Foster contacted the project designer to request the correct energy code forms and worksheets. To Request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following work day. Ue(]uire~nsDections I Framing Inspection: Prior to cover and after all rough in inspections have been approved. Wall Insulation: Prior to cover. Firewall: Located and constructed according to plans. Masonry: Ceiling Grid: After drywall approval but prior to cover. Final Fire Department. After all requirements of the Fire Department have been met. Final Building: After all required inspections have been requested and approved and the building is complete. Rough Grading: After gravel is in place but prior to placing concrete. Final Paving: After paving is complete. Rough Plumbing: Prior to cover and including required testing. Final Plumbing: When all plumbing work is complete. Backflow Device: Prior to covering and provide a copy of the test report on site at the time of inspection. Sanitary Sewer Line: Prior to filling trench and including required testing. Rough Mechanical: Prior to Cover Final Mechanical: When all mechanical work is complete. Rough Electric: Prior to Cover Final Electric: When all electrical work is complete. Fire Department Sprinkler System: Prior to cover. Hydro pressure test, fire line flow test. Fire Department Alarm System: Fire Department Alarm System Acceptance Inspection. This inspection must be requested and approved prior to requesting any occupancy approval. Fire Department Access. Inspection to assure access is available to site for construction project. This inspection is required prior to any combustible construction. Underslab Plumbing: Prior to filling the trench and including required testing. SUB Final: After all required energy inspections have been requested and approved. Pal!e 4 of 5 CITY OF SPRINGFIELD Status Issued Building/Combination Permit PERMIT NO: COM2006-01282 ISSUED: 07/19/2007 APPLIED: 10/09/2006 EXPIRES: 01119/2008 VALUE: $ 800,000.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line SUB Plumbing: Following City Rough Plumbing inspection approval and prior to cover. SUB Mechanical: Following City Rough Mechanical inspection approval and prior to any cover. SUB Ceiling Grid: Interior Lighting By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the peIJDJf;Card is 10cated~9te front of the property, and the approved set of plans will remain on the site at all tim~7;:d 71.1~/G7 r\:',,L v ~ - <..---' '/ / ~,x or Contractors Signature Date Pal!e 5 of 5 CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE WORKSHEET JOURNAL OR JOB NUMBER COMl006-0 1282 NAME OR COMPANY: Chuck E. Cheese WCA TJON: 3000 Gateway St. Space 540 MAP & TAX LOT NUMBER: 17 03 22 00 02300 DEVELOPMENT TYPE: Primary - Arcade / Secondary - Fast Food Restaurant (Pizza) / Tenant Infill NEW DEVELOPED AREA (S.F_): 8,167_00 Rest MWMC ITE: 933 NEW DEVELOPED AREA (S_F_): 8,167.00 SbopCtr Trans. ITE: 828 EXISTING DEVELOPED AREA (S.F.): 13,242_00 Arcade MWMC ITE: 895 EXISTING DEVELOPED AREA (SF): 13,242_00 Sbop Ctr Trans. ITE: 828 TOTAL IMPERVIOUS SURFACE (S.F_): LOT SIZE (SF): 1. STORM DRAINAGE IMPERVIOUS SQ_ FT no new impervious surface - teuant infill only x $ 0.336 PER SF 2_ SANITARY SEWER-CITY (see reverse side) A. REIMBURSEMENT COST: NUMBER OF DFU's 116 B_ IMPROVEMENT COST: NUMBER OF DFU's 116 TOTAL STORM DRAINAGE SDC:I includes new grease trap to be installed by landlord and demo'd DFU's x $ 26_03 PER DFU , , $5,315_12 J x $ 19_79 PERDFU ,,_ TO~~L LOCAL WASTEWATER SDCt 3_ TRANSPORT A TION no new transportation cbarges - previously paid for sbopping center BLDG AREA TGSF x TRIP RATE x COST PER ADT x NEW TRIP FACTOR NEW: A. REIMBURSEMENT COST: 8.17 x 32_8 B. IMPROVEMENT COST: 8.17 x 32.8 EXISTING: A. REIMBURSEMENT COST: -1324 x 32.8 B. IMPROVEMENT COST: -13.24 x 32_8 x $ 19.81 PER TRIP 0.65 NTF $3,449.33 1 $15,216.39 1 x x $ 87.39 PER TRIP 0_65 NTF x x NTF' PER TRIP x 0_65 NTF' ($24,671.90)1 TOTAL TRANSPORTATION REIMBURSEMENT SDc:1 TOTAL TRANSPORTATJON IMPROVEMENT SDC:' TOTAL TR.\NSPORTATJON SDC:I $0_00 I ($5,592_75)1 $ 19.81 PER TRIP 0_65 x x $ 87.39 4 SANITARY SEWER - MWMC new fees are difference between video arcade and fast food restaurant NEW: A. REIMBURSEMENT COST: NUMBER OF FEU's 817 x $894_65 PER FEU $7,306_61 1 B. IMPROVEMENT COST: NUMBER OF FEU's 8.17 x $7,491.88 PER FEU $61,186,181 EXISTING: A. REIMBURSEMENT COST: NUMBER OF FEU's -13.24 x $83_76 PER FEU ($1,109_15)1 B. IMPROVEMENT COST: NUMBER OF FEU's -1324 x $879.10 PER FEU ($11,641.04)1 MWMC CREDIT IF APPLICABLE (SEE REVERSE) TOTAL MWMC REIMBURSEMENT FEE: TOTAL MWMC IMPROVEMENT FEE: MWMC ADMINISTRATIVE FEE: TOTAL MWMC SDC:I $ _ 55,752_60 SUBTOTAL (ADp ITEMS 1,2,3, & 4) L___~,067_72 I 5_ ADMINISTRATIVE FEES: BASE CHARGE (SUBTOTAL ABOVE) $ 61,067_72 x 5% , $3,053.39 . TOTAL TRANSPORTATION ADMINISTRATION FEE: $ TOTAL SEWER ADMINISTRATJON FEE: $ Jeff Prociw Eng. Tech_ III 11/16/2006 DATE TOTAL SDC CHARGES $0_00 $6,197.46 $49,545_ 14 $10_00 $55,752_60 i 3,053.39 $64,12LlO DRAINAGE FIXTURE UNIT (DFU) CALCULATION TABLE NUMBER OF NEW FIXTURES x UNIT EQUIVALENT = DRAINAGE FIXTURE. UNITS (NOTE: FOR REMODELS, CALCULATE ONLY TIIE NET ADDITIONAL FIXTURES) Primary - Arcade / Secondary - Fast Food Restaurant (Pizza) / Tenant lnfil] FIXTURE TYPE BA TI-ITIJB DRINKING FOUNTAIN FLOOR DRAIN, FLOOR SINK INTERCEPTORS FOR GREASE/OIlJSOLIDS/ETC. INTERCEPTORS FOR SAND/AUTO WASHlETC. LAUNDRY TIJB CLOTHES W ASHER/MOP SINK CLOTHES WASHER - 3 OR MORE (EA) MOBilE HOME PARK TRAP (1 PER TRAlLER) RECEPTOR FOR REFRJGERATOR/W A TER ST A TION/ETC. RECEPTOR FOR COMMERCIAL SINK! DISHW ASHER/ETC. ** SHOWER, SWGLE STALL SHOWER, GANG (NUMBER OF HEADS) SINK: COMMERCIAL, RESIDENTIAL KITCHEN SINK: COMMERCIAL BAR SINK: WASH BASIN/DOUBLE LA V ATORY SINK: SINGLE LA VA TORY !RESIDENTIAL BAR URINAL, STALUW ALL TOTIET, PUBLIC INSTALLATION TOTIET, PRIVATE INSTALLATION MIsr~T To\NEOUS: ** includes 3 compartment sink, disbwasb pre-rinse, and disbwasher FIXTURES UNIT NEW OLD EQUTV ALENT 3 1 II 3 1 3 6 2 3 6 12 1 3 3 2 2 1 3 2 2 6 2 1 3 5 7 6 3 TOTAL DRAINAGE FIXTURE UNITS = , *EDU (Equivalent Dwelling Unit) is a discharge equivalent to a single family dwelling (20 DFU) set at 167 gallons per clay CREDIT CALCULATION TABLE: BASED ON ASSESSED VALUE IF IMPROVEMENTS OCCURRED AFTER ANNEXATION DATE IN TABLE, CALCULATE CREDITS SEPARATELY YEAR ANNEXED 1979 or L..fv,':'- 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 RATE PER $1,000 ASSESSED VALUE $52,9 $5,19 '$5.12 $4_98 $4.80 $4_63. '$4.40 $4.07 '$H7 '$3..22 '$2_73 .,.,,':$2.25 " '$1.80 YEAR ANNEXED 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 CREDIT FOR PARCEL OR LAND ONLY IF APPLICABLE IMPROVEMENT (IF At lbK ANNEXATION DATE) RATE PER $1,000 ASSESSED VALUE $1.45 '$L25 '$L09 ..$0.92 $0_72 $0.48 .$0.28 "$0;09 ..$0:05 . '$0.00 $0,00 $0.00 x x CREDIT TOTAL DRAINAGE FIXTURE UNITS o o 33 3 o o 3 o o o 9 o o 3 4 10 o 15 36 o o 116 $0.00 $0.00 $0.00 Spedal iJlap~ttloll ud TtaCtuGi To llppl!llmIS l>fllcQ/t:i:IS leqlli.iRI wa'n.t m,c.iion Qf' \~ 112 ,,1:1' Soo;tiaJlI104 uflht O~ S&rucUilPl Spl:didt)' CIlQt. l'Jl:ilsllnwltw IlK Ird'uroJllIioP hlO\9. \VbeII ygtlhllvc lTllind, lIWowfl:clgJllllllJlubSbSicrIll3 oflbc ioliulllo8lioo Iry s'~ea Wow. 9Dd KflIm.lIr>l: Io.rml(J Iflc Cil,y. I BJDlORE A Pan.\1Tl' CAN DK TSsmD: Thtlll\llll4iUlrU\mcI''J rq....-;.4:.... lIIJ ItIIt adW:c or !he, _...~jbJc ~ 1!Ilgtn=' OJ Arcbfb:c:L. Wdl _plcss. cIfJIo unddnllllo dLa ' Cily lOr wMK JDCi II/IIlllMlllhis Iilrm w~leI~ VII bIKIlltlc: lroll\ IlIIIl buck. - ' , , i - Tile O\Y11CJ 8Dd GcrIoral CDllllli~ wJ\t1lJ IJ'illitJlble. shIJ also 1Id.1l" l.J~..J lf1t;.liIIIlI'tillg a:mdtti OIlS appll.z1D to 'SpecW ]~ 1lIIIIl1K Tming. - I - I. ~...;_ is rcspollSitJle fOr. ~ '"' ., ~Qti~\)ll fur 1M Wpeclto>> ~Tcslil1& ofitJ:ms 1i5kd. I z. l"~IDhara1of7 .wIl ,....I/:~povpr1ob:.mtnpb l1!IIlllal!l$JlOrl fban III dJeir Ii'l . ,'''''' .., JilJ fJlOIJOf mdllllll1ljl III wlllg. t t;opics of s/1 ~iY n:{Il'I'ls llIllI il>spcdi0llS Il1C to k BIll 10 the cstY bl' the Teslirle~. . I ' J. Spcdal J~ Agctq i:J + RIlIlnil1l8ll:S 11II11 tjUlIIllka!Joai nftllt'411O 8]J11Cil11 fDapceW'S lD lflcCfI,s rorappo'llll. 4. Sp.:cfllHlI.1pcclur lha1I r"": ~~ 1......~.;:<oII RlJCII1$ !U l!1e bu)!lIlnI oftit,\d or aIliDlpcctiolll1diwilia. I 5. ClIJlIrIidgfjs mJllll'4lbll: /.0 .", I...... IE Cily ll{IpflWtd piau furadallUDIIllI~on~R5tinsrtq~lbaIll1II1-pQted. B(IJOltlC A cnrrIJlCATK () i OCCUPANCY WlLl. DE ~ 1'fr=specitl bup<<liuD ~ sIl1IIJ sulKaft ro clil: BlIIl!lllljf O/lll:.llll a 3Illlanmt Mall (Jan$~OC m." .~." h.we ba:aI fWmk1l BUd . _....;....: IlIKi \\'CI'B lD .11<: r.w g(1he m.."..1..., "lI1uJaI~ m Cllt1forma1lce vdlh 1M uppcllVCd pIanI, ~Ui",,' .,," IIllhpplil:ab~ ",....!-,...-oIUp pt'lJ'/flIII:m. ThJs\:!JIl:JM IIDl ~ flDdlof 1""I'_LJ JJm1I k1lOled kt 'Iu: JtII\:lnaII. 1\r:JqIOIt Is ID lis ~ to tK CIt1 (OJr 10 1l~pes161r Iinld i~ ~~:d. \ ~_ /J n.,Y~.'tCwr~ ~~ OwIltll'Namc{PrinkdJ.. . Q~~~ Ocn.C{)nirarlolfirmll'llfIlll(Prlillcd) ~ nlnlc:lDf~.gnature ..fJJr+er-+ g.~< . _ 'JV ~ Psr ~ '- ' "-p$;''''''~{p<r · gr"'~ ~".~~S~:1~ ~~<y ..~ / Testing u.ooI1l10f)' Nl&lne (Pr~tEd) Testing . TaIu~~ -;iJdmB ~~c (Pri ~ OI~ial :Slg6a~ . ~ @ -0 GO J:> ~~ ffi J r, u'. City ofSplingfil:ld COnUnUlllty SelYteu Dtvislou 225 Fifth Sfreot Springr.eJd, OR 97417 Telephone: (541) 726-3159 Fax: (S41) 726-3639 1C:>~ U>ob-O l'2..~"2- 7/LL t.ha-~<.~ _ Projees ,dIu 3tf) 64LMJI/ 5k~e+ . 'l'roJtcf Adlkes& -t:~kL <:> en t-' Ii~ .... .... t..:..... 0;0 ....--1 f'..l "" m~ ll\... .. lSl"" OIta ..~ ~~ ::: L -.f"'" ~ ~CD ~: ~ ...... l71g ~ .... (, co ~ ~. oil" ....'" l: ~!;J ~ i~ ~ (S) /0 snCIAL INSPECTION AN>> T~ING SU1W1JLE I - I RtinfOfC1ld CooCCCic:.. GlJl1illi. (irouL 00d Morlar;" Conmte Gmihl OtOll! I Mimill" I ----. r- G:QADlNG,I.'XCAV,\.l'ION, AND. fILl. A~/LliIC-mlS. PSF &IabWh final gllode FiU pfa!;CIIltlIl& mspectlDdca111fn1lllU$ . SliIImlsilJ' SfRuCTOllAL snKl.lWfi.DlNG% Snple 1IJll1U:11 (1i3l.c1fi5 mCl1l~bdo\V) SIulp mnraial ir.lmifnion (miU o:rl-) Wek1i1lspec.tiod ShOp, FidEI UIrrllJoak inspminn - SIloD. rdd -1-lI&bSlmTglhBalri~ 3fqJ. 1'1dcJ .a..ns _N- _X AM 1'1 X MeDl decl:.ltehlillg impe&Jion - ~g SIlllcI welding L '..' .~- , II lb:il\fiJn;ing~ mill <;olrDlical:t Md1115llHlwshing l~ Cl:lIIcmll ill5Clt welding irupediu~ MomeoI. ...:...:;....lIII:ClliaAell I , !'\-~fl!-Dlr: TESt 01 Mill De&il!ll RelMuc'iIll!TesI MIJ.Desjm-~Cert.. Rcinlortinl: PlllCUllClll C1Jl1\/1IIIll1I5 BlEb l'fJIIIf 1l'll[lCCl. IIUlJCd p~ C'ldl Slllll~ SamoblP"~i,md) I CmnuR:ssfoo 'r ul"' I"rcalJf1'J!.~ -:, ___.J c........:_ flks Post-TcllS I ~.Tm;J I I I I CIaddI~ ~~T~ lWnfllTCillfl: Tcm TaPaD TUl Mix.~ R.IdnfoI~lI: PIaccml:Ill ln$m llamPcDl c.:n:1e 1Ill1I:htnJ CoIJQdt:~ T~ rr-lim ('.as{ S::Imoles Pitk-uD ~ j CoPIllfCSSiQll1 ~r$ SfillJClURAL WOOlJs Shcm' \nllJl2ifj~ Imf~on SJtcar \lIIII ,.,.1. .'.. T~ tlf(]lu.lm11lU. · r/C psi lnspullllll Df lrUSS jolsl f.IlJ. Sample: IlIl&d fc:st QIOlfDllrnt5 ~wcltingohkcl acc........,:..; SMOla: CON"rROl.: .~Ieslin; CorirnlVe,ifu:al111f1 I'IRUDllOJINC: c c 0 ~ C1 U ...' I- meA> ~ ...,l-' " w' C! Q)c C! ......~ ~ l\J ~I-' I- 0'1::' u ... ego..> ,-I' Ul " .. ." ~~ No U ..... .p ..,.... .... Na;> ~ (TJ0. .p lJloo a '""- Dig; .... a ..... u. F 00 f o ,> ~ rn ::0 Sl'> otx;l L t-I ~ if. <0 I- I;j~ I;/) ~ ~ ~ l'lKaIIClll inspc;liaR DtfISiIY laI3 Tht.;..,......~ I~buldlinl: MAS{}{IlIl'IJ Spcdul ~~.;:~n sbcmS mcd't J"m. r g fnl:;" .:. ,.~. .-..I......tt lul3{muodry QlIiB, 'oWl1 prisIns) SLI..... .",jltslS(mDJ1ar, gI1lIIl. fii:hI'lI'III',ma1,) ~a1l i~ oftmits. apd re1nrorcCAl8Id Mas1DY t lJlOIW. grolIl" MIl reld~ !ICe! Cf:I8UCllkll ROOPT1fQ:. i l.ns.lililtian ~mVR- Value* TUIs(ri~~ . I I I - t\DDrrlONAL lNSRUCfIONS.! O'T'IRk nsr. & INSfECTIONS: - '--L4y .,.~ rpJ~"j FDmI COl!1fltltd. by:.J::j:u/'d ~"'~ I I 1-- - . -- . ".l'flOVlDE ~RENGTH REQ UlRW BY ARCRlTXCT OR E~(;I ~R OR CONTRACT DOC VMENT l.OC\ TION OF VA L.Ufi,S Du; GIJ//~? , 'lJ 1> m rrw-o o 1> ISla Gl 00 c.o fT1 a loJ' 225 Fifth Street Springfield, Oregon 97477 541-726-3759 Phone City of Springfield Official Receipt Development Services Department Public Works Department Job/Journal Number COM2006-01282 COM2006-01282 COM2006-0 1282 COM2006-0 1282 COM2006-0 1282 COM2006-0 1282 COM2006-01282 COM2006-01282 COM2006-01282 COM2006-0 1282 COM2006-0 I 282 COM2006-01282 COM2006-0 1282 COM2006-0 1282 COM2006-0 1282 COM2006-01282 COM2006-0 1282 COM2006-0 1282 COM2006-0 1282 COM2006-0 1282 Payments: Type of Payment Check cReceintl RECEIPT #: 3200700000000000485 Date: 07/19/2007 Description Fixture Sanitary Sewer - 1st 50 Feet Backflow Device Sanitary Sewer - Reimbursement Sanitary Sewer - Improvement SDC MWMC Reimbursement SDC MWMC Improvement SDC MWMC Administration SDC Sanitary/Storm Admin Building Permit Boiler/Comp 3-15 HP Vent Fan Appliance Vent Exhaust Hoods Gas Outlets 1-4 Gas Outlets 4+ -Mechanical Issuance Fee- + 5% Technology Fee + 8% State Surcharge + 10% Administrative Fee Paid By CEC ENTERTAINMENT Item Total: Check Number Authorization Received By Batch Number Number How Received njm 551109 In Person Payment Total: Page 1 of 1 8:42:06AM Amount Due 336.00 45.00 56,00 3,019.48 2,295.64 6,197.46 49,545.14 10.00 3,053.39 2,840.65 88.00 12.00 6.00 27.00 4.00 1.00 10.00 170.78 273.25 341.57 $68,332.36 Amount Paid $68,332.36 $68,332.36 7/19/2007