Loading...
HomeMy WebLinkAboutPermit Building 1996-12-6 (2) COMMERCIAL/INDUSTRIAL e PERMIT APPLICATION ~ e JOB NUMBEn --c;.iRJf, Z L INSPECTION LINE: 726.3769 OFFICE: 726.3759 225 Flflh Slreet, Springfield, Qlegon 97477 LOCATION OF pnOPOSED worm: __ }Q.?_Q()':E}_s__S~,,~et (Dorris -.!'.'~1,,:1~)_ - ..- .---.------------- ASSESSORS MAP' lR 01 02 00 TAX LOT: 802 OWNER' Willamalane Park & Recreation District ADDRESS:~ 1nth Street CITY: Springfield PHONE: __.726-4330 STATE: _ OR 97478 ZIP:_ DESCRIPTION OF WORI(: Renovation of interior of Tomseth House including new partitions and new plumbilW NEW REMODEL _X__ ADDITIO ____ DEMOLISH OHlER --.-.--,__.ESI. VALUE: _.. $.8.,000 NAME ADDflESS PHONE ARCHITECT- None CONTRACTOR'S NAME GENERAL: Willamalane ADD RESS 680 36th Street. Sofd. CONST. CONTRACTOR' 97478 102974 EXPI RES PHONE 726-4330 6!l&-4191 PLUMBING: Soecialtv P lu-"ping____._._ MECHANICAl' None selected yet ELECT RICAL: '.. .-.-- -+.--- -.-------. .--.--....---- Single Fixture Relocated BI<lg. -1r!ew Ilx. addlll Waler Service Pl\1Mi1i.f,jg______ _oo.____~ FEE CHARGE ------00-;0-- --fO~~ IIo\~CflANICAL I 11 _NQ_. __'_00__ Furnace/burner & venl < 100,000 BTUs Furnace/burner & venl > 100.000 BTUs -EEE-. _CI:IABGE..... II. Floor furnace and venl -'Slispcnlic<f-Wfiiiorlioor--- llIounled ullll healer -.Appliancei.i"l,i---- scparale Stationaryevap. cooler --VeniFaniSinglc duel VenlSysTein apart Irol11 AC or hlg. -Mecllanicaf exhaust hood and duel S'anifary-Scwc'iU.h.. -.--....., . -... II. -Slorln. Scwe;-.----.-----.--- II. Oacl(t1ow Device Permit Issuance $10.00 TOTAL PEflMIT ~,oO TOTAL PEflMIT - OFFICE USE - HANDICAP ACCESS:_ FLOOD PLAIN: _...... QUAD AREA: ____ LAND USE:__ . OF BLDGf'. . OF UNIT'" lONING: OCCY GROUP: · OF STORIES' CONSTR. TYPE: HEAT SOURCE: LIGHTING POWER BUDGET: . WATER HEATER: SO. FT. $/SO. FT. VALUE SO. FTG MAIN SO. FTG ACCESf x x SO. FTG OTHER x TOTAL VALUE OF PROJECT PLAN CHECK FEE ~f 5"3 A .- IleFl' DAT~ BY I BUILDING PERMIT 15% Slale Surcharg_e I MECHANICAL 15./0 Slale Surcharae I PAVING PLUMBING -1- [). t:>-O -15.2.0 DEMOLITION 5% Slale zDO+/2l Surcharge {, FENCE VALUE $ - srDEWA~- FT. -suBioTAi:---- __u_ PERMITS SYSTEMS DEVELOPMENT CURBCUT FT. TOTAL PERMIT FEES EXCLUDING ELECTRICAL r g7 73 . .-.-- .._---. ---.-----. ... .......-.......-.. .~...._._.__._.- ---..-.------- .--- e REQUIRED INSPECTIONS e II is the responsibility of the permit holder to see that all Inspections are made at the proper time. To request an Inspection, call 726.3769 (recorder), slate your City designated job number, job address, type of inspection requested and when you will be ready for Inspection. Requesls received before 7:00 8.m. will be made the same working day, requests made after 7:00 a.m. will be made the following work day. SITE INSPECTION: To be made after excavation, but prior to setup of forms. I UNDERSLAB PLUMBING. ELECTRICAL & MECHANICAL: To be made before any work Is covered. _x ~'.GH PLUMBI~ ELECTRICAL & MECHANICAL: No work is to be covered until these inspections have been made and approved. PAVING: Aller gravel Is In place but prior to placing asphalt or concrete. FOOTINGS & FOUNDATIONS: To be made after trenches are excavated and forms are erected, all steel in place, but prior to placing concrete. FIREPLACE: Prior to placing facing materials and before framIng Inspection. SPECIAL INSPECTIONS: In accordance Section 306 of the State Specialty Code a special Inspector shall be employed by the Ownerl Contractor during construction of the following work. A copy of the special testing reports shall be furnished to the Bulfdlng Division. ATTfC DRAFT STOPS & CURTAIN WALLS CONCRETE SLAB: To be made after all Inslab building service equipment, conduit, piping, accessories and other ancillary equipment items are In place but before any concrete Is placed, FRAMING: To be made after the roof, all framing, fire blocking and bracing are In place and all pi pes, chimneys and vents are complete and the rough electrical, plumbing and mechanical are approved. STRUCTURAL CONCRETE: In excess of 2500 PS.1. (306 a.1) STRUCTURAL WELDS: Performed on the job. (2722 f) UNDERGROUND: Plumbing, electrical, gas, sanllary sewer, storm sewer, water and drainage lines. To be made prior to covering or filling trenches. INSULATION & VAPOR BARRIER: To be made after alf insulation and required vapor barriers are In place but before any lath or gypsum board Interior wall covering Is applied. HIGH STRENGTH BOLTING: During all bolt Installation and lightening opera'lons. (306 a.6) SPRAYED ON FIREPROOFING: U.BC. Standards 43.8. UNDERFLOOR: Plumbing, electrical, mechanical. To be made prior to Installation of floor Insulation, decking or floor sheathing. FIRE & SEPARATION WALL: Located and constructed according to plans. SPECIAL GRADING, EXCAVATION AND FILLING: During earthwork. (306 8.11 & Chapter 29) POST & BEAM: To be made prior to Installation of floor InsulatIon, decking or floor sheathing. LATH AND/OR GYPSUM BOARD: To be made after all lathing and gypsum board, Interior and exterior, Is In place but before any plastering Is applied or before gypsum board Joints and fasteners are taped and finished. GLU.LAM BEAMS: Inspection Certificate by an approved agency, furnished to the City's Building Division before beams are placed. (2501 U.B.G. STDS. 25-10,11), FLOOR fNSULATION & VAPOR BARRIERS: To be made prior to Installation of decking or floor sllCathlng. STRUCTURAL MASONRY: (306 a.7) MASONRY: Steel location, bond beams grouting or verticals In accordance with UBC 2415. SIDEWALK & DRIVEWAY: Required for all concrete paving withIn street right of way, to be made after all excavating complete and form work and sub-base material in place. ROOF SHEATHING AND NAILING: Prior to Installing any roof covering. CURB AND APPROACH APRONS: After forms are erected but prIor to placing concrete. *In addition to the Inspec- tions specified, the BuIlding Official may make or require other inspections of any construction work to ensure compliance with the Building, CI ty or Development Code. ------------------------------------------------------- 'X FINAL ELECTRICAL SITE PLAN REVIEW BOARD: Must be requested 2 days in advance of the date you wish Inspection. All project condItions such as fandscaplng, parking lot slrlping, etc. must be completed before requesting this Inspection. FINAL PLUMBING FINAL MECHANICAL FINAL BUILDING: Requested after the final plumbing, eleclrlcal, mechanical and Fire Department Inspections are made and approved. No occupancy of the premises can be made until a Certificate of Occupancy has been issued by the Building DIvision and posted on the premises, FINAL FIRE DEPARTMENT ADDITIONAL COMMENTS: ?(/./g,<!/",12 APv".</eb'5 AtI('.~ 7Z' jJ~~.T 1"?IA.,c /&(ULA.:>--~!y. .~ hPt=. .~ JZH- .d?.?~r T# "uhJ/ilP_ V--ofZL A/I 1~ /.d~~'irr ?ktt5 /<;;J//~ E lJo .o~ r/~~ V ~~- ~~ /Y~/7X ~ r. t"~//rp~ ) jZl(~ PLANS REVIEWED BY OATF C,FU~.17 77D ~L ,-If)": ~i By signature, I state and agree, that I have carefully examined the completed application and do hereby certify thpt all Information herein is true and correct, and I further certify that any and all work performed shall be dore'ln accordance,wlth the Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Building Safety Division. I further certify that only contractors and employees who are in compliance with ORS 701.055 will be used on this project. I further agree to ensure that all required inspection,s are requested at the proper time, that project address Is readable from the street, that the permit card Is located at ttle front of the property. and the approved set of plans will remain on the site at all times durIng constructIon. SIgnature Date VALlOATION: AMOUNT RECEIVED: RECEI PT ': "? '2 C' n \- ;7 ~- ~?,73 DATE PAID: RECEIVED BY: J? -_I:. - 5'~ . ./~......-> -, ~