HomeMy WebLinkAboutBuilding Correction Notice 1983-3-21 . . SPRINGFIELD CITY OF SPRINGl"lliLD Department of Public Works r~arch 21, 1983 Ms. Pamela D. West U.S. Department of Housin9 and Urban Development Area Office Cascade Building .. 520 S. W. 6th Avenue ,Portland, Oregon 97204 'Dear Ms. \~est: / , At your request, the Building Division of the City of Springfield made a Housing Inspection on March 3, 1983 at the following locations. The following items were found in need of repair or replacement to conform to the 'Housing Code as adopted by the City of Springfield. All applicable permits must be obtained and all items shall be installed in accor- dance with applicable Codes and inspected before a Certificate of Compliance will be issued. City Job Number 830557 860 North 23rd Street 1) Extension sleeves shall be installed in all electrical boxes not flush or beyond the finished surface of paneled walls. 2) IIhere a grounding means does'not exist in a receptacle.enc10sure_ only nongrounding type of receptacles shall be used as replacement receptacles. 3) All electrical receptacles, switches and junction boxes shall be provided with approved covers or face plates. 4) The bedroom windows shall be made openab1e for emergency egress or rescu~. 5) The wall surface of the shower enclosure shall be of water resis- tant material a minimum of 6 inches above the shower head. 6) The clotheswasher drain shall be connected to a separate and in- dependant water seal type trap. 7) Remove the hardware hose c1 amp on the water pi pe adjacent ':to the hot water tank. 225 North 5th Street . Springfield. Oregon 97477 · 503/726.3753 . . 1 Ms. Pamela D. West Housing Inspection March 21, 1983 Page 2. 830554 2386 Dornoch Street .(...' 1) Extension sleeves shall be installed in all electrical boxes not flush or beyond the finished surface of paneled walls. 2) All electrical receptacles, switches and junction boxes shall be provided with approved covers or face olates. 830555 383 South 42nd Place ,1) Where a grounding means does not exist in a receptacle enclosure only non-grounding type of receptacles shall be used as replacement recep- tacles. 2) All electrical receptacles, switches and junction boxes shall be pro- vided with approved covers or face plates. 3) Electrical receptacles shall not be located above baseboard heaters. 4) The bedroom adjacent to the kitchen area shall be provided with a window or exterior door that will provide emergency egress from that room. 5) Repair or -replace the bathroom floor and wall surfaces that have de- teriorated due to excessive moisture contact. 6) Reali gn ,and secure the front posts that supprot the carport roof. 830902 335 South 42nd Place 1) All electrical splices shall be made in approved junction boxes. 2) Electrical receptacles shall not be located above baseboard heaters. 3) The bedroom windows shall be made openable for emergency egress or rescue. NOTE: At the time of the inspection the underf100r area of the structure was covered wtih approximately 6-8 inches of water. 830487 6835 - 6837 Aster Street No violations of the Housing Code found. . . Ms. Pamela D. West Housing Inspections March 21, 1983 Page 3. ~ 830556 2385 Dornoch Street Wrong Address Please direct all inquiries to the Springfield Building Division at 726-3753. I .~ci ""Jrl David J. Puent ~ lJ' Building Inspector DJPllh