Exterior Wall Envelope; . '.'
Self-Certification Forin~
I, iS~. .lh-I.J { S
owner-builder at the following address:
. . .
. ...
.
. .
. .
. . .
. ..
... .
.... ..
. ....
. ....
... ..
. .. ..
. . . '.
. am the general contractor or the
k'N)l~ ~
(UQ- c; 2.S-
Permit#
To conform to the 2008 Oregon Residential Specialty Code (ORSe), Section
R703.1.1, I am notifying the building official that I am aware of the exterior wall
envelope requirements of R703.1.1, and hereby certify thatthe components of
the exterior wall envelope have been installed in accordance with the code
requirements. [Section R703.1.1 is provided for reference on the reverse side of
. . .
this form.]
Signatur.
''8'" - C)~- 10
Date
Revised: 2/8/2010
.
... .
.' .. ..
. .. .
. .. .
.. ..
.. .
.
. .
. .
. .
. .
.
.
..
.
.'
.
...
..
. .
. .
..
. .
. .
,
,
I,
.. ..
. . . .
. . . .
.. ..
.. .
.. .
... .
. . . .
. . . .
.. ...
. . .
. . .
... ..
..
. .
. .
.
.Exreiptfro..; i008 Oregon Residential Specialty Code Section R703, 'Exterior Covering:
.. .. ..: '
. . '. .
R703.1.1 Exterior ,Wall Envelope. To promote builCting durability, the exterior wall envelope shall
be installed in a mannerthat water that enters the assembly can drain to the exterior. The envelope
~~illl consi.t rjf an exterior veneer, a water-resistive barrier as required in R703.2, a minimum 1/8
:nc.h space~eMen the water-resistive barrier and the exterior veneer, and integrated flashings as
r..quired' IltR703.8. The required space shall be formed by the use of any non-corrodibleJurring
strip, drainage mat or drainage board. The envelope shall provide proper integration of flashings '
with the water-resistive barrier, the space provided and the exterior veneer. These components, in
,cOnjunction, shall providea means of draining water. that enters the assembly to the exterior.
Exceptions:
1. A :5pace is not r~.quired where the exterior v'eneer is installed over a, water-re~istive,barrier
complying with section R703,2 which is manufactured!n a manner to enhance drainage and
, meets the 75% drainage efficiency, requirement of ASTM E2273 or other. recognized
national st,ni,dards:, ' "
2. A,space is not required wher"window sills are equipped with'p~n flashings which'drain to
the exterior, surface of the veneer in a through wall fashion: All pari f1ashingnliall be
detailed within the construction documents and shall be of either a self-adhering, '
membranecomplying'withMMA 711-07 or 0.1 an approved corrosion~resisiant material or
a'combination thereof, Self-adhering membranes extending to the exterior surface of the
veneer shallbe conce~ledwith trims or other,measuresto protectfromsunliglit. '.
'3. Aspaceisriot requiredwhere,the eXterior veneer is manufactured in a manner to enhance
dn.inageand meets the 75% drainage efficiency requirements ofASTME2273 Or other
r.ecog~ized national stan~ards and is installe~ over a water resistive barrier, complying with
sectionR703.2. ", " , . . '
4. A space is not required ,where the exterior veneer is matching an existing exterior finish as
in additJons, a~lt~rations"or.'rep~irs. . . . .
5. A'wateHesistant eXterior wall envelope shall not be required over concrete or masonry ,
walls designed in accordance with Chapter 6 and flashed according to' section R703.7' or
,R703.8., , , .. ' . '," '. '
6. . Compl!~u;'cl!! with the requirements for a means of drainage, and the requirements of
, Section R703.2 arid Section Rl03.8, shall not be required for an exterior wall envelope that
has been demonstrated to resist wind-driven rain through testing of the exterior wall
envelope; incl~dingjoints, penetrations and intersections with dissimilar materials,in
accordance with ASTM E 331 under the following conditions:
6.1. Exterior wall envelope test assemblies shall inClude at least one opening, one control
joint, one wall/eave interface and one wall sill. All tested openings and penetrations
, shall be representative of the intended emd-use configuration. ,
6.2. Exterior wall envelope test assemblies shall be at least.4 feet by 8 feet in size.
6.3. Exteri,orwall assemblies shall be tested at a minimum' differential pressure of 6.24
pounds per square foot. .
6.4. Exterior wall envelope assemblies shall be subjected to a minimum test exposure
duration of 2 hours. ' " .
The exterior wall envelope design shall be considered to resist wind-driven rain where the
results of the testing indicate that water did not penetrate: control joints in the exterior
wall envelope; joints at the perimeter of openings penetration; or intersections of
terminations with dissimilar materials.
..