Loading...
HomeMy WebLinkAboutMiscellaneous Compliance Report 2010-8-25 III . .. .. . . . . . . . '!!1r . . . . . . 1!"'.rHE ..... .. ;! ii, : :: : /BUILDING iJ1?EPARTMENT. 4~~ . . .. ... . Exterior Wall Envelope; . '.' Self-Certification Forin~ I, iS~. .lh-I.J { S owner-builder at the following address: . . . . ... . . . . . . . . . .. ... . .... .. . .... . .... ... .. . .. .. . . . '. . am the general contractor or the k'N)l~ ~ (UQ- c; 2.S- Permit# To conform to the 2008 Oregon Residential Specialty Code (ORSe), Section R703.1.1, I am notifying the building official that I am aware of the exterior wall envelope requirements of R703.1.1, and hereby certify thatthe components of the exterior wall envelope have been installed in accordance with the code requirements. [Section R703.1.1 is provided for reference on the reverse side of . . . this form.] Signatur. ''8'" - C)~- 10 Date Revised: 2/8/2010 . ... . .' .. .. . .. . . .. . .. .. .. . . . . . . . . . . . . .. . .' . ... .. . . . . .. . . . . , , I, .. .. . . . . . . . . .. .. .. . .. . ... . . . . . . . . . .. ... . . . . . . ... .. .. . . . . . .Exreiptfro..; i008 Oregon Residential Specialty Code Section R703, 'Exterior Covering: .. .. ..: ' . . '. . R703.1.1 Exterior ,Wall Envelope. To promote builCting durability, the exterior wall envelope shall be installed in a mannerthat water that enters the assembly can drain to the exterior. The envelope ~~illl consi.t rjf an exterior veneer, a water-resistive barrier as required in R703.2, a minimum 1/8 :nc.h space~eMen the water-resistive barrier and the exterior veneer, and integrated flashings as r..quired' IltR703.8. The required space shall be formed by the use of any non-corrodibleJurring strip, drainage mat or drainage board. The envelope shall provide proper integration of flashings ' with the water-resistive barrier, the space provided and the exterior veneer. These components, in ,cOnjunction, shall providea means of draining water. that enters the assembly to the exterior. Exceptions: 1. A :5pace is not r~.quired where the exterior v'eneer is installed over a, water-re~istive,barrier complying with section R703,2 which is manufactured!n a manner to enhance drainage and , meets the 75% drainage efficiency, requirement of ASTM E2273 or other. recognized national st,ni,dards:, ' " 2. A,space is not required wher"window sills are equipped with'p~n flashings which'drain to the exterior, surface of the veneer in a through wall fashion: All pari f1ashingnliall be detailed within the construction documents and shall be of either a self-adhering, ' membranecomplying'withMMA 711-07 or 0.1 an approved corrosion~resisiant material or a'combination thereof, Self-adhering membranes extending to the exterior surface of the veneer shallbe conce~ledwith trims or other,measuresto protectfromsunliglit. '. '3. Aspaceisriot requiredwhere,the eXterior veneer is manufactured in a manner to enhance dn.inageand meets the 75% drainage efficiency requirements ofASTME2273 Or other r.ecog~ized national stan~ards and is installe~ over a water resistive barrier, complying with sectionR703.2. ", " , . . ' 4. A space is not required ,where the exterior veneer is matching an existing exterior finish as in additJons, a~lt~rations"or.'rep~irs. . . . . 5. A'wateHesistant eXterior wall envelope shall not be required over concrete or masonry , walls designed in accordance with Chapter 6 and flashed according to' section R703.7' or ,R703.8., , , .. ' . '," '. ' 6. . Compl!~u;'cl!! with the requirements for a means of drainage, and the requirements of , Section R703.2 arid Section Rl03.8, shall not be required for an exterior wall envelope that has been demonstrated to resist wind-driven rain through testing of the exterior wall envelope; incl~dingjoints, penetrations and intersections with dissimilar materials,in accordance with ASTM E 331 under the following conditions: 6.1. Exterior wall envelope test assemblies shall inClude at least one opening, one control joint, one wall/eave interface and one wall sill. All tested openings and penetrations , shall be representative of the intended emd-use configuration. , 6.2. Exterior wall envelope test assemblies shall be at least.4 feet by 8 feet in size. 6.3. Exteri,orwall assemblies shall be tested at a minimum' differential pressure of 6.24 pounds per square foot. . 6.4. Exterior wall envelope assemblies shall be subjected to a minimum test exposure duration of 2 hours. ' " . The exterior wall envelope design shall be considered to resist wind-driven rain where the results of the testing indicate that water did not penetrate: control joints in the exterior wall envelope; joints at the perimeter of openings penetration; or intersections of terminations with dissimilar materials. ..