HomeMy WebLinkAboutPermit Building 1998-11-10 . , ~, SPRINGFIELD Job Number: 981214 Page 2 HANDICAP ACCESS: Y ZONING CODE: LMI QUAD AREA: lINW LAND USE: 3999 Item Sq. Ftg Main Square Feet 15870 x $/Square Feet Value 640,000.00 TOTAL VALUE OF PROJECT 640,000.00 Plan Check Fee: 1,002,95 Rec #: 31584 Date: 09/29/98 Rec By: AL WARD BUILDING Surcharge/Admin MECHANICAL Surcharge/Admin PAVING VALUE 40,910.00 PLUMBING Surcharge/Admin SIDEWALK CURB CUT CITY SDC FEES IN-LIEU-OF ASSESS, 1,543.00 123.44 113.50 8.29 242.50 445.00 35.60 29.65 21.70 18,198.72 7,739.20 SUBTOTAL PERMITS 28,500.60 TOTAL PERMIT FEES EXCLUDING ELECTRICAL 28,500.60 REQUIRED INSPECTIONS It is the responsibility of the permit holder to see that all inspections are made at the proper time. To request an inspection, call 726-3769 (recorder), state your City designated job number, job address, type of inspection requested and when you will be ready for inspection. Requests received before 7:00 a.m. will be made the same working day, requests made after 7:00 a,m will be made the following work day. Special Inspections: In accordance with a special inspector shall be employed by construction of any following 11*11 work. shall be furnished to Building Safety. Section 306 of the State Specialty Code the Owner/Contractor during A copy of the special testing reports In addition to the inspections specified, the Building Official may make or require other inspections of any construction work to ensure compliance with the Building, City or Development Code, GRADING/EXCAVATING/FILLING - To be done during constr by Special State Certified Inspector. Provide reports/tests to City Building Inspector FOOTING - After trenches are excavated. STRUCTURAL CONCRETE in excess of 2500 psi. To be done during constr. by State Cert. Insp. Results to City Building Inspector BOLTS INSTALLED IN CONCRETE - To be done by State Certified Special Inspector. Provide inspection/test reports to City Building Inspector FOUNDATION - After forms are erected but prior to concrete placement. UNDERGROUND PLUMBING - Prior to filling trench, UNDERGROUND ELECTRICAL - Prior to Cover, Page 1 COMMERCIAL/INDUSTRIAL PERMIT APPLICATION CITY OF SPRINGFIELD Job Number: 981214 COMMUNITY SERVICES DIVISION BUILDING SAFETY 225 North Fifth Street Springfield, OR 97477 Office: 726-3759 Inspection Line: 726-3769 Location of Proposed Work: 1940 DON ST Assessors Map #: 17032700 Tax Lot #: 00903 Owner: GREGORY STRAUSBAUGH Phone #: 501-3139 Address: 3642 RIVER POINTE DRIVECity/State/zip: EUGENE, OREGON 97408 Description Of Work: INDUSTRIAL BUILDING NEW Value: 0.00 Name Address Phone Architect: RON THIENES Const. Contractor Contractor # Expires Phone General: OWNER Plumbing: TWIN RIVERS PLU 0017695 03/11/99 688-1444 PO BOX 40397 EUGENE OR 974040000 Mechanical: COMFORT FLOW 0000460 06/27/99 726-0100 1951 DON ST #D SPRINGFIELD OR 97477 Electrical: JB ELECTRIC 0104929 03/14/99 687-5770 1786 BALBOA ST EUGENE OR 974080000 PLUMBING --- No, 21 Fee Charge 210,00 40.00 40.00 145.00 10.00 Single Fixture Sanitary Sewer Water Service Storm Sewer BACKFLOW DEVICE 72 55 763 ft. ft. ft. TOTAL PERMIT 445.00 --- MECHANICAL --- NO, Fee Charge 30,00 21. 00 24.00 24.00 4.50 10.00 7 Furnace/burner & vent < 1000,000 BTUs Vent Fan/Single Duct 4 UNIT HEATERS 4 AC UNITS 9 GAS OUTLETS Permit Issuance TOTAL PERMIT 113.50 -- OFFICE USE -- SPRINGFIELD Job Number: 981214 Page 3 SLAB - TO be made after all ins lab building service equipment, conduit piping, and other equipment it~ms are in place but prior to concrete HIGH STRENGTH BOLTING - To be done during constr by State Certified Special Inspector. Results provided to City Building Division, STRUCTURAL WELDS - To be done during constr by State Cert Special Inspector. Results of inspection/test to City Building Inspector. ROUGH PLUMBING - Prior to cover. ROUGH GAS - after line is installed and capped if not attached to an appliance ROUGH MECHANICAL - Prior to cover. ROUGH ELECTRICAL - Prior to cover. ELECTRICAL SERVICE - Must be approved to obtain permanent power, FRAMING - Prior to cover. INSUL-V.B./SUB: TO BE CALLED FOR AT SAME TIME AS SUB FRAMING INSPECT MECH/SUB: FOLLOWING ROUGH MECHANICAL APPROVAL, PRIOR TO COVER DRYWALL - Prior to taping. CURBCUT - After forms are erected but prior to placement of concrete. SIDEWALK - After excavation is complete, forms and sub-base material in place, FINAL PLUMBING - When all plumbing work is complete. FINAL GAS - When all gas work is complete. GAS SERVICE - After line is installed and line has been connected to a minimum of one appliance. Pressure test done at this point. FINAL MECHANICAL - When all mechanical work is complete. FINAL ELECTRICAL - When all electrical work is complete. FINAL/SUB FINAL FIRE - When all Fire Department requirements have been met, been met. FINAL SITE PLAN - After all requirements have been met for Minimum Development Standards or from the Development Agreement. FINAL BUILDING - When all required inspections have been approved and the building is complete, --- ADDITIONAL COMMENTS DRC 98-05-102, PLANNER IS MARK METZGER DRC JOURNAL #98-05-102, MARK METZGER, PLANNER Plans Reviewed By: LORNE PLEGER Building Site Reviewed By: LISA HOPPER Date: 11/04/98 By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701,055 will be used on this project, I further agree to ensure that all required inspections are requested at the proper time, that project address is readable from the street, that the permit card is located at the front of the property, and the approved set 0' ,"" .", ",..,. o. '''ji\\' .. ." "." ,,",., 00"'"'0"0' ",4zuci~ .,::-IO-'/g Job Number: 981214 - -- VALIDATION Receipt Number: ~~/~ Date Paid: //-~ ,~~ Amount Received: ? 4J;1 ~;.::> -- " - Received By: /?7~ // Page 4 .. ,- . vVV"""L V"(""VC "":;/70("<'/"7' ATIACHMENT A CITY OF S~NGFIELD SYSTEMS DEVEL4IMENT CHARGE WORKSHEET NAME OR COMPANY: "':;/&t'~ ;i/'/t'Lvc: .h4-UJL /deh-/ &/1, o/e':uV:jl> LOCATION: /7'9'0 a" ~h.eei- DEVELOPMENT TYPE: /1.hu.~ gld.~ hr C5hsi'Jvc..k~A 6v~;'u;5 lOW (/ BUILDING SIZE: /.,i), /3 70 LOT SIZE /0-1 5~+" SQ. Ft. , r 1. STORM DRAINAGE- R"t7I-I//';v( +- Ale.. -:: 33 r Jj"S -" hz,R"l /~ ~ IMPERVIOUS SQ, FT,1'~,,~ x $0,227 PER SQ, FT, $7,;57/~ e=:;- 2, SANITARY SEWER-CITY c8 NO. OF PFu's.22 X $47,14 PER PFU $ 11'>37 - -: (See Reverse Side) r p ;-! 6'~I 7 {I/o )&-4> '/ '-r -r-r.L.. "/":.rl'r::--I - '0.2.li 3, TRANSPORTATION <.. Teh~4(rYCJV'{CW?I/~~n~ - &1 C,67F' NO OF UNITS X TRIP RATE X COST PER TRIP 9.. /l/3 X .9h X $475.32 ~(".~ X .7'/ X $475,32 .a.. $ t;.r,,J.'1/ , r sl $ 1?L/r- - 7 J;M M~ G,~33~ ~ -r;"", 7( , .y7 $ r/( ;((!) /- , 4, SANITARY SEWER-MWMC A. REIMBURSEMENT COST: .." 7L: NO, OF FEU'S".6:" 87 X l!h PER FEU B. IMPROVEMENT COST: ~ NO, OF FEU'S fi5" 8 7X 1;< PER FEU TOTAL-MWMC SDC $ /79 ~ ot> < $ .502.1 - > $ 10,00 $ ,q6'lcP- ~ II $/7.:13';:- , G" $ ~- MWMC CREDIT IF APPLICABLE (SEE REVERSE) MWMC ADMINISTRATIVE FEE , SUBTOTAL (ADD ITEMS 1.2.3'& 4) 5. ADMINISTRATIVE FEES: BASE CHARGE (SUBTOTAL ABOVE) X ,05 ~~..& Date: l/r7~ /T sa ~rdi nator ATTACH'A.WPD TOTAL SDC z> $ /8. /.98 ; , ." I "'. I'" ...,.... ....,,.,...""va..I"'1. I IV'" II""\UL.L.. l~umoer or l'few ilXlures ^ unn I:qUlvalenI = I"'IXTure Units {NOTE: For remodels, calculate only the NET additional fixturesl . NUMBER OF . FIXTURE TYPE' NEW FIXTURES .. - UNIT FIXTURE EQUIVALENT UNITS 2 1 2 3 6 2 6 6 1 3 ..1' 2 1/Head 2 y 2 1 J 6 4 / ,;z. Bathtub.,..,.....,....,.."..........,......,....."'.....,...,.,..,.....,.. . Drinking Fountain.., ...,.., ....,...,...... .....,',.......,.,.......... Floor Drain,.......,..,..,...,...........,..,...."....,......,............ Interceptors For Grease/Oil/Solids/Etc......... ........ Interceptors For Sand/Auto Wash/Etc.................. Laundry Tub/Clotheswasher...,....., .........".,....,....,.. Clotheswasher - 3 Or More...............................,..... Mobile Home Park Trap (1 Per Trailed.................. Receptor For Refrigerator/Water Station/Etc........ Receptor For Commercial Sink/Dishwasher/Etc.. I Shower, Single StalL,.."..,.,........., ........."..............,.. Shower, Gang.,... ......,.....'.......,.,..",.."".,....,....,.....,. Sink: Bar, Commercial, Residential Kitchen........................ ;L. Urinal, Stall/WaiL.,."."..".,.....,....."""",..,.,.......,....,.. Wash Basin/Lavatory, Single.................................. _=? Toilet, Public Installation....,.., ,........,......,....,...,...... Toilet, Private....................................................... _1 Miscellaneous: TOTAL FIXTURE UNITS ,~,~ = CREDIT CALCULATION TABLE: Based on assessed value, If improvements occurred 'after annexation date in table, calculate credits separates. .1 Year Annexed ~r before 1980 1981 1982 1983 1984 1985 1986 1987 1988 Rate per $1,000 Assessed Value ~ 4.18 4.12 3.99 3.83 3.68 3.48 3.18 2.82 2.42 Year Annexed Rate per $1,000 Assessed Value II 1989 1990 1991 1992 1993 1994 1995 1996 1997 $1,98 1.55 1.15 0.96 0.83 0.67 0,52 0.38 0.21 i/.' ,27 Credit for Parcel or Land Only If Applicable 17 -;{"J- = 0(, 302/ - X $ {Rate X Assessed Value I X $ (Rate X Assessed Value) CREDIT TOTAL Improvement lif after annexation date) = ~" ~"'/~ = $ ~, RUNOFF COEFFICIENTS FOR STORM DRAINAGE (For Estimating Purposes Only) ResidentiaL.......................... 0.4 Commerical:........................ 0.9 IndustriaL........................... 05 Governmental...................... 0.5 FIXUNIT.WPD IMPERVIOUS AREA = TOTAL LOT SIZE X RUNOFF COEFFICIENT