Loading...
HomeMy WebLinkAboutPermit Miscellaneous 2010-11-3 o...:. SP~.1~IN..~FI~L~ ~..~.."iO'" ;';;j1' ~ ,;&,.{O'",. OREGON CITY OF SPRINGFIELD Building I Residential Permit PERMIT NO: 811-SPR2010-00633 IVR Number: 811141694841 www.ci.springfield.or.us 225 Fifth SI Springfield,OR 97477 Phone: 541.726.3753 Inspeclion Phone: 541.726.3769 Fax: 541-726-3676 permitcenter@ci.springfield.or.us PROJECT STATUS: STATUS DATE: Issued 11/03/2010 ISSUED: APPLIED: 11/03/2010 11/03/2010 EXPIRES: VALUE: 05/02/2011 $2,000.00 SITE ADDRESS: 465 MILL ST 1. Springfield, OR 97477-4507 ASSESOR'S PARCEL NO: 1703352308600 SCOPE: Miscellaneous WORK INVOLVED: New TYPE OF STRUCTURE: Residential PROJECT DESCRIPTION: Solar water heating system Phone Nu'mber: OWNER: ADDRESS: ST VINCENT DE PAUL 705 S SENECA RD EUGENE OR 97402 CONTRACTOR INFORMATION ~ Contractor Type General Contractor Plumbing Contractor Contractor Name PACIFIC SOLAR & RAIN INC PACIFIC SOLAR & RAIN INC # of Units: o Lic Type eeB PLUMBING BUILDING INFORMA nON ~ # of Stories: Height of Structure: Type of Heat: Water Type: Range Type: Hazmat: # of Bedrooms: Sprinkled Building: Fire Alarms: Energy Path: Electrical Specialty Code Edition: Springfield Fire Code Edition: Mechanical Specialty Code Edition: Municipal J Development Code: . Plumbing Specialty Code Edition: Residential Specialty Code Edition: Structural Specially Code Edition: Lic No 173918 PB278 lie Exp 01f19f2011 07f01f2011 Phone 541-556-4527 541-338-7054 lot Size: Sq Ft 1st Floor: Sq Ft 2nd Floor: Sq Ft Basement: Sq Ft Garage: Sq Ft Carport: Sq Ft Other: Oceupan~y load: o Site Information ~ Engineered Fill: Fill Volume: Flood Hazard Area: land Hazard Area: Retaining Wall: Soils Report Required: . ,.'..,}' NonCE: L EXPIRE IF THE WORK THIS PERMIT SHJI.L IS PERMlT \S NOT ATTENTION: Oregon law requires you to . AUTHORIZED UNDER TH 0 FOR follow rules adopted by the Oregon Utility COMMENCED OR IS ABANDONE Notification Center, Those rules are set forth ~NY 180 DAY PERIOD. in OAR 952-001-0010 through OAR 952-001- 0090. You may obtain copies of the rules by calling the center. (Note: the telephone number for the Oregon Utility Notification Center is 1-800-332-2344), Springfield Building Permit 11/3/2010 8:53:10AM Page 1 of 3 ... SP:~N.G.-..m.~ li~~""'ll>'" ~ ~. \lJliol' ^l~::;'-, OREGON WWN .cLspringfield,or,Us CITY OF SPRINGFIELD Building I Residential Permit PERMIT NO: 811-SPR2010-00633 IVR Number: 811141694841 225 Fifth St Springfield,OR 97477 Phone: 541-726-3753 Inspection Phone: 541-726-3769 Fax: 541-726-3676 permilcenter@cLsprlngfield.or.us PROJECT STATUS: STATUS DATE: Issued 11/03/2010 ISSUED: APPLIED: 11/03/2010 11/03/2010 EXPIRES: VALUE: 05/02/2011 $2,000,00 SITE ADDRESS: 465 Mill ST 1, Springfield, OR 97477-4507 ASSESOR'S PARCEL NO: 1703352308600 SCOPE: Miscellaneous WORK INVOLVED: New TYPE OF STRUCTURE: Residential Frontyard Setback: Interior Setback: Sideyard Setback: Rearyard Setback: Solar Setback: Solar water heating system DEVELOPMENT INFORMATION I Overlay Dist: # Street Trees Reqd: Paved Drive Reqd: % of Lot Coverage: Highest point on struc~ure to north property line: REQUIRED PARKING PROJECT DESCRIPTION: Total: Handicapped: Comp~ct: PUBLIC IMPROVEMENTS I Street Improvements: Storm Sewer: Storm Sewer Available: Speciallnstructon: Subdivision Accepted: Notes: Sidewalk Type: Downspout/Drains: Valuation Description I Descriotion Tvpe of Construction Unit Amount Unit Tvpe Unit Cost Value DescriDtion Structural Building Permit Fee Solar water heating system Balance,,?f Minimum Plumbing Permit Fees State _of Oregon Surcharge (12% of applicable fees) Te~~log~ fee (5% of permit total) Total Amount Paid FEES PAID Amou'nt Paid $58.00 $19.00 $39.00 $13.92 $5.80 $135.72 ~ Date Paid 11/03/2010 11/03/2010 11/03/2010 11/03/2010 11/03/2010 Receiot # 374780 374780 374780 374780 374780 Springfield Building Permit 11f3/2010 S:53:10AM Page 2 of 3 . S,.P:ING FI E:ii. D . r ,~ ~^^ 'OREGON CITY OF SPRINGFIELD Building I Residential Permit PERMIT NO: 811-SPR2010-00633 IVR Number: 811141694841 www.cLspringfield.or.us 225 Fifth St Springfield, OR 97477 Phone: 541-726-3753 Inspection Phone: 541-726-3769 Fax: 541-726-3676 permilc~nter@ci.springfield.or.us PROJECT STATUS: STATUS DATE: Issued 11/03/2010 ISSUED: APPLIED: 11/03/2010 11/03/2010 EXPIRES: VALUE: 05/02/2011 $2,000.00 SITE ADDRESS: 465 Mill ST 1, Springfield, OR 97477-4507 ASSESOR'S PARCEL NO: 1703352308600 SCOPE: Miscellaneous WOR~ INVOLVED: New TYPE OF STRUCTURE: Residential PROJECT DESCRIPTION: Solar water heating system Plan Review ~ DeDartment Application Acceptance Received Due Date ComDleted 11/03/2010 11/03/2010 11/03/2010 Result Application Accepted Initial Review 11/03/2010 11/03/2010 11/03/2010 Approved Reviewer David Bowlsby David Bowlsby . "- ""',- .11103/2010 ,:1.1/03/2010:: ,'1"1/0312010;' * Approved'~ ''<r --.':..~~;-c__..~,;_ri~ __:_~.-~---t_--~_-.-~..~._..t_.e-_:.r__.t:','._:~.'_:':..-'__:.~'~_:-._ _ ,_' '.. ~'.~. ~~;:'>>L,,~ ..::;~7?l7:tir4:1,,~itl~~~~:;~;':;:i~":_: ~_:~ o~t;. ;~.'-'\f}~~~:'i ;:~_.~~- ~~., ' - -.~........4$""'," ,:'m .. ..:. ...... - Framing Inspection: Prior to cover and after all rough in inspections have been approved. Final Building: After all required inspections have been requested and approved and the building is complete. Rough Plumbing: Prior to cover and including required testing. Final Plumbing: When all plumbing work is complete. INSPECTIONS REQUIRED ~ Inspections 1260 Framing 1999 Final Building 3500 Rough Plumbing 3999 Final Plumbing l By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State or Oregon'pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. 1 ~/~/1o Date Springfield Building Permit 11/3f2010 8:53:10AM Page 3 of 3 SP~~.N.G.:..IEL~ ~A',~ ,,' ~,.~ .~,~~i\. OREGON www.ci.springfield.or.us TRANSACTION RECEIPT 811-SPR2010-00633 465 MILL ST 1 CITY OF SPRINGFIELD 225 Fifth 8t Springfield,OR 97477 541-726-3753 permitcenter@cLspringfield.or.us RECEIPT NO: 2010000736 RECORD NO: 811-SPR2010-00633 DATE: 11/03/2010 tDESCRiPTIONlj"X-"'0,,<,:,qI":;ll- "':;s~'1'1'.1.i-: :. Structural Building Permit Fee Solar water heating system Balance of Minimum Plumbing Permit Fees State of Ore~on Surc~':I~~e (12% of applicable fees) Techno.IE.~Y fee (5% of ~ermit total) w.;< , te: i;lC<:..O:U}JT'CQQgi..+i'; -- '-:AMOl!l'ItDuE'\+ 224-00000-425602 $58.00 224-00000-425603 $19.00 224-00000-425603 $39.00 -- 821-00000-215004 $13.92 100-00000-425605 $5.80 TOTAL DUE: $135.72 'COM~ENTS' ,,-XL .. F., -.- ;~AMOUNTf'AID 1 l .PAVMENJ TYPE :''\;-, PAVOR;:- '-CASHIER: ,?,!?WLSBY Credit Card 054711 PACIFIC SOLAR & RAIN INC $135.72 $135.72 '.l,:~ PACIFIC SOLAR AND RAIN, INC. Contact: Luke Rabun PH: 541 .556 .4527 CCB #: 173918 BCD #: PB 278, STL #: 124 Solar Hot Water Permit Information City of ~~::;ftt '3pf;{/uj-f!cld 'Building & Permit Services Required information for solar hot water units. A. Location of the collectors on the roof. Job # Date: \\/2.2.0ID Trusses JlQ Stick Framed 0 Spacing of Rafters 2-' ?'o~t-- \oc"'~ , 4~ r ~~.l S,~~7 I"L~o Llb I~U 510-Q...~ ~., 'a.JATE t(1:.l..t:.JVl:::9 y~ ( ..I - . ~. _, .~([ ~~-, '}"r.Nc"i..!3",.c;:..I, . N '~.r~.'''t:.' ~ ,~,_. -- Size of Rafters Span of Rafters Slab ~ A I0ffta:illegdl1>daw rnq ires you to fall w ru es 0 regon Utility Noti .. IlJ,f,n "QJ!b1!ll,j'ules are setforth in 0 R 952.001.0010 through OAR 952.001. 009 . '{a1/f ~"O nlth" rill". hy ca i he <<!1.Ql1lf. J'loU~: the telephone nu ber for tfie;.'Ortgd~'Ulilily t~ulifiv"liulI lWlfeisichilDjjI;a:02-2344) . .. ~) _ -- _ _~: _ _ ._.._.":_;___""'..~..,~.. A,<< B . f h k' h h 1',~lIT(~~_.-.-__~.. B ...,....;-.,~'.'1 . Locatton 0 t e tan In t e ouse. BTO';:;;C;".c.. 'd;:--",,~"~, 6'~~ Lllsl~< DE<;C'21PT'O>l12C>3J..:?f:S._.--_..~~_n___.. 1\- " .,..'e'" t{/s: l"I"~a_~_._ ...' - .., .h....'" _.Q.. ., .L_L. ::~: ..;", "">T 1(1,o/c.eMr _.h'_~=----'-' ~,..1...L,-,- L _u . " .-. '!':~l ..'i"l..'.' He'."'- O'-J H --:'}.il" '.-l.';{)'~':~ :-~~VI~_.\'!..L, .1', , . THE c.:;r)NTENTS _.:.~2-'::. ~_)'.. ""~J:l:'-.:"~7;J:?,;~j' FZ>lCl!-. ChP;..\.~:l';~E ; Al -r.rw:.l.r;.,",-IO'.IS IN.D'',_','''' .<:.D .~ ,>.; '-~:. .-~., ~>'--'''':I__'''''''' On -""i~.'.': -;:.j 0 :~ '-I~~'" D!:'o' .r-,....' .,~'-l\::: ~,M\,....'\... "'......1.) ':,......~ ..',.".,' OR ALTC:l;:ft:r~9~S_+)'H~~.:'.-.'";-r'T~,,",':'~U:~"~;''i{q-.iALi... u\!7.: AF{:Jh:CVli.:D:'/ PROJt::CT;:"r;El~ ~ c.!...>n.!I:;,........ ...~~ '. THE.BUIL.01NG OF:-IC~AL. ~. CITY OF 5PRINGFiKLD, OfxEGO. ., It C. Anticipated weight of Collectors and ffifl~~~l) BY \ 5\ (~II.k el,Iei-) Ibs ~lL ~"Ibs Collectors , NOTICE: THIS PERMIT SHALL EXPIRE IFTHE WORK AUTHORIZED UNDER THIS PERMIT IS NOT NDONED FOR Tank D. Details of how the unit will be connected toPffl'e1~flrt}&'t&r&IOD. . See attached E. Manufacturer's Specifications and installation instructions. . See attached Notes: \tJe o.s'<. 't.... ~\\l-<. ~ ~'O s.\>,.,,,,-k Sc~w lJ-J"'-\"". 1,N",-f1'1 ~S-lrW\5 ",,1- IS ""'cY,cSS E<<.lA. ~'S-lt-""" w:l\ $"'''1/10" DVI.~. ~r workr (ex,-sh'-.'J) , ~o\v1 ~ 5""''''''1-< -\---t..b u...J ~ II I<X \o(<<"~..J ~ -n..... ISi ~{oor tA ~ \t{ rcn.^",-. Ihv.... uJ;U ~ -i"t-vo ~:-w..rr-i-- S:c:k.r' OI.N'A.'1S i'~d."p.-...Jl"'~+- of 8--ck e,-tN r . E<<cL, <iJ'.{ of' u..J .. II eoV'\~\~;'+' 0{ 'iv-Jo (2) SoIw colkcfof 5>, 'i '.' 3rv:L7 :rw;;y N \ ~-t ~~ N o ..{~ J T ~r }t; \J J ,1;-1 " ... T S tiO~ ~~\.l1 VI ", '" is 8 v IJ.! 1 :1,..\ 1.\1 gl\1 3 ~ )- ...~ 01 < W ~ ~ ..J 5 d. z o ~ $~ ~ '" 0 .!l \fl ~ 0 \ '" H I'l \I I :r- ~ --' <( -.D' "2.'" H~ ;j.~ ~V') c..:: -+ r{\ ~ t J ~ & I " () 11 - ~ I~ ~ - IJi ]:::9 J :J' ~ ., j-j~...\ ~~;e!-S ill -, ~ . ~~~3JJ 25:. a ..." '.. ~\ , '. .1\ t ... ''\, J) ::\ h E ,[) ..l> T ::t ~ ~ ~ BJ8J VI g '\o! ,>, ~~ -=r tJ ~ ?- < j~ C> rl 0 ~v>\J i- 'J'l ~ .~ "l'1 lu < ~ '" "'N ~ H (\,:' ~<.:..::. ,..)-' v~ , D a ?~ v1 Q "'" <>J lJ 1\.1.-;- .:2 -t: ~ 1-:-- ~ / _I.... "'t ~ 0.00( ~... k \f\ t- -' ~ -.l k" -~~--------.- ----------- , , I I I I I "-------1 I , L__________________I II @) I : I I , , 'I , , , 'I , , ~ a: \ II ~~ : 1 ~~, : I (I i) ~~::I ~ ~: : I , 'I , I 'I , , , I , 'I "- - - - - - -- - - - -- - - - - - -- - - --- -- - - - -~1D1~ ~~~~~~~~~- ~ is I I I I . S ~ ~ ~ ~ 8 ~;/>."I ...L-. ~9>Z~ ~~ ~13;B ;/ a. oj g > ~~ ~~ " ;~q~~ ~~~6~ ~u~ ~ i i~~d~ z ~~ ~ ~ L ~B@)@)@) S H6l (t ~ ~ - . ~ ~ W ~ j Dl ~ " ~ - , ii -' ~ . . ~.~ . ~SU h. ~~i ~ ~"i eU~~ ~~ ~~~~ ~ ~~ ~ ~nh ~i ~E~~ ~ ~~ ~ U~~Eh~~ ~~~~.~~" ~ e~U~uh i ~~n~~~11 i i!!lunuJd~uu~;~ ,--------1 I I I I I I I I I I I I I I I I '" ~ ~ cr ~ S @ ~~ ~~ I~~ mh Uli hi~ '0 I ~ ~ ~ ~ ~ -I r II ~ -....'-,-' ~~ ~ ~ ~ ~ Ud ~ ~ ~ n~ ~ ~ ~ ~ ~~i~~~~ h~€>@l @@ I ~~ U $~~ ~ I.~~ h I ~~~ O~ @g -- ~g~ h a un ~ u z <( -' 0... ~ u.J l- V> >- V> z U ;; Z ~ w >< .Z 3 -< ~ c.:r:= Cl~ Cl t: Z <~ ~~ -< 0:: -< ...J o Vl u u.. U ~ '" ~ o ~ .- ,.:..: o u.J ~ u.J 0... I V> V> ~~ . ., Solar Servant™ HE Solar Heat Exchanger, Solar Tank, or Electric Storage Water ~ - ~ ... . Available in 80 and 120 Gallon Models ~ ::J ~ 6-Year Umitecl Tank and Parts Warranty" .. I " . Brass drain valve · Cold water inlet brings cold water to , · Choice of two models...storage tank or tank bottom to prevent mixing with 7 single element water heater specifically heated water e '"; engineered lor installation with residential · Anode rod equalizes aggressive water action , indirect solar systems for prolonged tank fife .j · Temperature and pressure relief vaJve included · Cold water inlet, hot water outlet, relief valve ~ · Collector feed and return fittings located at and anode rod at top of tank lor easy access . front of tank lor convenient installation and fast, economiCal installation · Isolated tank design lor better heat · Automatic temperature control retention · Over temperature protector e . High efficiency heating element . See Residential WalTall% Information Brochure · Ruudglas tank lining resists corrosion and ...... " ~ prolongs tank life for complete warranty in rrnation. · Heat exchanger: copper tubing wrapped @~ around and secured to the tank. Double wall, vented design for positive leak detection I ~ESCR!PTION ROUGHING IN Dli,1ENSIONS jSHOWr, IN INCriESl ENERGY IriFORr.1ATlON . -- - . - ,. -- - ..- --- -.- -. l -. - . .. ~ I E'~EI,IEtIT . M'P1:fO\ AJ'Pl'lO. P ] GAL I \.::....Tt.GE dK-l IA',IET"," S"'Jr\'.~ R " i CAP. nrQEl:,w'.Ii'ER U"?"R '" I 6 \ltlSJ rACIOn 80 RSPEBOHE.l 80 RSPE80HE- T 120 RSPE12OHE-1 120 RSPE12OHE-T 4500 W" Storage only 4500 W" Storage only 58-314 58-&4 62 62 24-1/2 24-1/2 28-114 28-114 222 222 380 380 R-17.3 R-17.3 R-17.3 R-17.3 . Heete", furnished wllh standard 240 volt AC. slngIe phase ~ wiring end 4500 watt heating element . " heating ._18 of d1flerent _gee then those ehown ... _ded by zone requlremenl8, they must be speclficetly requested. . To prevent corrosion, proper pH levels in transfer f1ukl must be maintained. . Solar Servant models meet all current state requirements for solar slonIge tanks. . The tanks are Ruudglas lined and are designed to operate up to 150 PSI. A special 1/2" NPT opening is provided for installation of a "probe type" thermostat. . e \.... fP 7 , .Ji , WATER COHNECnOH NIPPlES ALL3f.- H.P.T. COPPER COIL DATA (Type L Copper) Maximum pressure = 150 PSI Maximum temperature = 1850 F Tube 1.0. = 5/8" I " HOT It OUTLET I I " O!l " . " " " COU) INLET Solar Servant HE Tank C 80 Gallons 120 Gallons Co/I Capaclty Gallons 2.2 2.6 Length 01 Tubing Around Tank FI 120 143 I A Flow Rate 1 GPM 2GPM 3GPM PRESSURE DROP THROUGH COIL (FaeI 01 H,O) Head Lose (Feel) 80 Gallon 120 Gallon 1.3 1.6 4.8 5.7 10.0 12.0 ,. WATER CIRCULATOR (REQUIRED FOR ~ GRAVITY SYSTEIIS) III keeplllg With Its porlcy of contll1l;lOiJS progress and product Improvement, Ruud r~serves the right to make changes without notice Ruud Water Heating' 101 Bell Road, Montgomery, Alabama 36117' www.ruud.com PAINTED IN U.S.A 06/08 WP FOAM NO. 101R"16 Rev. 11 ,"- / ", ~ ECIli:P20 36 lIS'. . 78'u" 31/" 19.10 17.30 60' 0.60 0.51 .015 .2 160 39 3i4 7j'I/'2. EC/EP24 36 liB 98114 3114 24.6' JI.88 80 0.18 0.61 .017 12 160 393/' 93 5/8 EC/EP32 481/8 98.114 3114 32.79. 29.81 106 '-<Xl 0.83 .ot8 12 '60 513/8 , 935/8 6i C/EP 4a 1/8 fll 1/4 .3 1/4 40.81 37,33 14' 1,10 1.04 020 12 '60 513/8 115 SI8 MODEL EC THERMAL PERFORMANCE RAnNGS. MODEL EP 13) EMPIRE COUECTOR SPEOFICATIONS !r~~~~:~-~;:::"2'::.:;I\Th~~~;Z:I!~~:-.z=~:::i =<'9"'" CLEAA MllOl.V ClOUOY fTl-ral <>'oy CLOUDY ~y <>'oy TI.iOlfta.-s.... 2COO 1500 ICOO 1'6.~_1IImP IInu1t'1Ooy IInu1t'1Ooy IInu1t'1Oay .' AWn'." .. ";";332:' ".' "'-:1.005," 680, 8""" '.J" !190 5'5 ,'C 36.F ';.'UMO':.,';,. .- ':',:720; ; '. : '402 0 ... 405 .27 'f' E f''''4 .- ::~90'" '.:-:137 .-.-". .... .. Bru/ft21 -~~~--=-::.:::Z'~;:IT;=..:~.~E:" .:~==~__-,.J 1lluIft'''''''' Ca<ego<y CJ.EN MILDLY CLOUDY IT'""" """ CLOUDY DAY O<\y n._liUcI..... 2COO 1500 1 COO 1:..wnOlrnI........ IInu1t'/Day BluIft'/Day BluIft'/Day '. "'."'1 .' 1.284 .'911' . .:. ..' 'S~"., 8'" 1.169 8" ..2 36 984'-. . 677. :. ;,.,i! "311:'::-';.' o 9O"F .,. 343 .. E 144'"F' ""., 280 .2 .- .;'~:'::t~<'.' ' ,&,.pool Heatfng jWarm CImoteJ 8-Pool HNIing C-water' HearIng fWMn ClimitI:e:I D-Win'r Heating {Cool CIrrtale) E-Air ConalrlonfngllnduStrfat Prccl!5$ Heat. Thermal ~ Is otxaIned Dy muIltpt)llr\g tne' COlleCtOr 0U1PA" fOf' the appopNte' appIIc.mon and InSO&iIUon ~ by tne roral gross c-<:lUecIor area. .CQ~tof ratings are CJen'Ved!tom me SOW Raing & cemtlcalfon Corp ~q Doc~nt RM.' anc:l Standard OG-l 00. The rciItowing sI1aII be the specifications for the solar colleClOO. COIlectoo shall be Sunfarth Empire model and shall be of the glazed liquid ftar plate type. Collectors lhiiI be leSled In cortOlTMlCe IMtIlASHRAE 93-1'186. and SRCC IrosL The colleaoo also shall be certitied by the SRCC and the Ronda Solar Energy Center jFSEC/. GENERAl. The dimensions Of the cofIector shall be inCheS In length. inches in v.idt!l and 3 1/4 Inches In depth. The collector cas. ing shall be an anodized aluminum exlrU5ion ~ 6063 T5). IIlinin1um lhctness .060 Inch. v.ith an arctrile<nJraIdaIk bronze finisIl. The cas. ing shall have nolCI1ed ~amewallS for ease of pIale removal and reinstallation. Sheet rnetaI scfeYJed fastener; st\all be stainless steel /18-8 #10). The back5heel shall be painted IelCIIJIl'd aIunirum not lesS than .014 inch tI1ickness. A I inch vent plug shall be installed in each of d1e four comers of the backlhe€l to minimize condensation GlAZING The colle<tor glazing 5I1aU lle one sl1eeI of lOw iron tempered glass. with a minimum of 1/8 inch thickness 15/32 inch on EP/EC 40). and a minimum transmissivity of 91 perren! 189 on EPIEC 40). The giazing Shalllle them1aIIy isolaled from d1e casing by a continuous fPDM gasket There shall be a continuous secondaly silicone seal between the glass and casing capsuip to minimize moisture from.entering the Casing. INSUIA1ION The insulation shall' be foil-faced ~ foam s/leaIhing board of a minimum I Inch thictness. siliconed in place to d1e afuminum backsheel covered by lowOOder Iillerglas5 ct a minimum 1 inch thida1ess. Pfl'Jiding lhem1aI isliation ri d1e foam from d1e absoiber pare. Tocal thermal resistance sl1aIllle a minimum of R.' 2. The sides and ends of the collector shaIIlle Insulated with a minimum of 1 inch foil-faced poIyisocyanurate foam sI1eall1ing boatlI. A8S0R8Elt PIA1'E AND PIl'lNG The abSorber shall consist 01 a roIl{ooned copper plate of no lesS than .008 inch lhctness. Risers shall be a minimum ct 1/2 inch 0.D. Type M copper tubil1!j on no more man 4 1/2 inch cenlffi corlinuouso/ soldered to the plate utilizing a noocorrosM! solder paste v.ith a melt. 'ng po,nt of 460 F. The risers shall be brazed to I 1/8 inch O. D. Type M copper manifolds utlizing a copper pIlosphomus brazing aII~ with no less than 15 perren! silver content, and conforming to the American Welding Society5 SCuP.5 classification. EPOM gmmmelS shall isolate the manifold from the aluminum casing. The absorber plate shaIIlle designed for 160 psig maximum operating pressure ABSORBElt COAlING AND PEIIfOIlMANCE CURVE AI Black Chrome IEC Series): The absorber coaling lhiiIlle black chrome on nickef with a minimum absorptivity of 95 perrent and a maxi- mum em~sivity of /2 perrin. The instatr.aneous efflciency of the cOllecror shaIIlle a minimum Y~ntercepl of 0.714 and a slope of no less than -0.7271 /8TU/ft'-l'Yj1F. . 8) Moderately Selective 8/ad( Paint (EP Series): The absorber coaling shalllle a moderaleiy-Seleaive black paint wilh a minimum absorptivity of 94 percent and a maximum emiSSMly <X 56 perren!. The instantaneous efficiency of rhe colleaor shall have a minimum Y~ntercept of 0.682 and a slope of no lesS man -0.7995 {BIUIII'-I1r11F. Sp<<ificatioo, ,ubject '" change wiIhout noIice. P.21 , , 0 ~I ex: " <( ~ i~ 0 VI Z ex: ~~ ~~~ ~~ ~ -,w -~~ VI -t x ~ ~<( ~a ~~~ \ I.:) Wex: Z 00 , , VI , \ 1.:)1- l \ :)1.:) zz Oz - - \ w- !z::; II VI VI :)1- <(:5 OU /' ~::i! /' - u:u... (' ~i WW u...O / ce9:: 90 ~ / i / 00. ~! , (~ ow U Ih ~ 1 t I-~ Zl.:) ~~ VI-' -" ~~ ~g5g e; : u...<( I- ~1l "'" . < ~ u...U a:. ~~ M~"15 Lf~ 0' 0 VI -' ~ ~' ,0 ~~ -t=! ~ OZ ~~ ;;:;'^ "" Z. u.:~ ~S u.. 'N VI~ ~M ill ~ , ::;~ 1-'<1" ~~- O~ We. Z ~ t;:;w > - ",N '" \:Ie. 0 zw ~Vi ex: zw <( ::>0 0 00 Z ::;::; ~ u..a:. ~i :t:u..O ~ VI 1-01- ~ II I.:) a:.'u e(t; <Ow ,,~ ~~ Z wZ-" l:!Z Z -" U i! e! Vi ::>~O -' :)1.:) ",,,,u ~ ~.. Oz '"" I w- w ~2 II 0 I VI VI \ <(<( \.:7 -,-' Z u...u... I- WW Z ce9:: :) 00. 0 ( I-~ - VI-' ~ i !~ / u...<( u...o h u...U ~ ~~ O' 9w I ,0 O~ ~2g~ ~ OZ ZU II ~~~ ~"'~~ ~ Z. ~9 ~h :.:s~. " <(<"I w I-~ VIce 5i~ ~ ~ VI~ .. w::: , 1-'<1" O~ Z~