Loading...
HomeMy WebLinkAboutPermit Building 2010-10-15 ilirjlj 10/15/2010 City of Springfield 2:01:08PM Building Permit & inspection Summary Job #: COM2009-01778 225 Fifth Street 541-726-3753 Phone Job Address: 3841 EST SPRINGFIELD 541-726-3676 Fax Scope of Work: Single Family Residence Project Status: Deferred Payment Description of Work: Single family residence -***********DP A ********** Owner & Contractor(s) Name Address City, State, Zip Phone CON BANYAN CONSTRUCTION LLC 3419 VIDERA DR EUGENE OR 97405 541-434-1333 ELC HARDING ELECTRIC INC 3039 WINTERCREEK ST EUGENE OR 97405 541-688-5006 ELC STEVE HAUCK 828 SOUTH 46TH STREET SPRINGFIELD OR 97478 541-221-2665 MEC LOWES WEATHERIZATION POBOX 21337 EUGENE OR 97402 541-485-2282 OWN KLM CAPITAL INC 9712 SW ALABAMA ST TUALATIN OR 97062 PLM T & S PLUMBING INC PO BOX 42274 EUGENE OR 97404 541-915-1000 Valuation of Proiect Date Occupancy Construction Type Cost Per SQ Ft SQ Fte: Valuation Calculated Staff Estimate Estimate $ 1.00 179,000.00 $179,000.00 2009/12/14 DJB SF/Duplex R-3 VB 1&2 Family $ 96.83 1,301.00 $125,975.83 2009/12/14 CJC Garage/Misc U VB Utility $ 37.72 237.00 $8,939.64 2009/12/14 CJC $313,915.47 Fees Paid Description Amount Paid Date Paid Receipt # SDC MWMC Reimbursement $101.97 12/16/2009 1200900000000001338 SDC MWMC Improvement $1,044.54 12/16/2009 1200900000000001338 SDC MWMC Administration $10.00 12/16/2009 1200900000000001338 Total Amount Paid $1,156.51 Plans Reviewed Department Received Due Date Completed Result Reviewer Comments Planning Review 12/14/2009 APP DDK "'PLAN REVIEW'" Public Works Review 12/14/2009 12/14/2009 APP LKW Roof runoff from Lots 3 will be directed to the existing city stormwater system through an 8" stormwater pipe in the j9int utility trench. Structural Review 12/14/2009 12/15/2009 APP CJC As noted on plans Inspections Conducted Inspections Comments Date Result Inspector Final Building Final Plumbing Final Mechanical lof4 '1.......~_.....~.'.....,.', Ilk: 'I ,. . I ,.WW.. , City of Springfield Building Permit & Inspection Summary' 10/15/2010 2:01 :08PM Job #: COM2009-01778 225 Fifth Street 541-726-3753 Phone 541-726-3676 Fax Job Address: 3841 E ST SPRINGFIELD Scope of Work: Single Family Residence Description of Work: Single family residence -***********DP A ********** Project Status: Deferred Payment Drywall Erosion/Grading Inspection Stom1 Sewer Line Framing Inspection Wall Insulation Ufor Electrical Ground Footing Foundation Temporary Electric en. l.NEC250.50:Can not find ground rod. 2.No plans on site. I) provide anchor bolts within 12 inches of the end of the sill plate. ORSC R403.1.8.1 2) provide underfloor access to all locations under floor ORSC R 408.3 3) provide 1/2 inch clearance from wood to concrete ORSC R 502 4) NOte plumbing not complete Post and Beam Underfloor Plumbing Underfloor Mechanical Underfloor Mechanical Temporary Electric Post and Beam Floor Insulation called sub. correction made. correction cocmplete contractor requested second inspection not ready in late . afternoon Underfloor Plumbing Floor Insulation Rough Plumbing Rough Mechanical remove mechanical duct from under stairs fill in hole in wall then reduct renail all shear wall s that have Over driven nails Shear Wall Nailing All shear walls to be nailed at 6 inches on center on the edges and 12 inches in the field 12/17/2009 12/17/2009 12/17/2009. 12/18/2009 OK OK OK NOK RWC RWC RWC BAR 12/22/2009 NOK RWC 12/22/2009 NR SKG 12/22/2009 OK SKG 12/22/2009 OK RWC 12/23/2009 OK BAR 12/23/2009 OK RWC 12/23/2009 NR RWC 12/23/2009 OK SKG 12/24/2009 OK RWC 02/02/2010 NR RWC 02/02/20 I 0 NOK RWC 02/02/2010 NOK RWC 20f4 ap.,A~I~~.F;~m~iii ...... i Wil: .., l' . . . I ....:. ! City of Springfield . Building Permit & Inspection Summary 10/1512010 2:01:08PM Job #: COM2009-01778 225 Fifth Street 541-726-3753 Phone 541-726-3676 Fax Project Status: Deferred Payment Job Address: 3841 EST SPRINGFIELD Scope of Work: Single Family Residence Description of Work: Single family residence -***********DP A ********** Framing Inspection I) provide window flashing 2) provide attic access of 22x30 3) provide moisture conlnet letter 4) provide details for cut floor joist, or r~place with new one where plumbing has removed the top plate 5) strap top plate where removed by plumbing or electrical 6) provide trusses clips on all trusses 7) replace studs at electrical panel where more thau 40% of the stud has been removed 8) replace interior barring wall at the kitchen! stairs with 2x6 studs ( note plumbing has bored a 2 inch hole in a 2x4 wall) only leaving 1/2 inch on each side 9) fix stud where mechanical duct has removes studs under stairs 10) plumbing not ready/ electrical still setting boxes Hold Downs Installed Rough Electric Shear Wall Nailing Low Voltage Post and Beam Exterior Underfloor access provided 2/3/10 correction complete moisture content letter see file for details corrections complete moisture content letter see file Left correction notice: I.Please install long 90 degree fitting on kitchen sink vent and slope 1/4 inch per foot toward drain where located below 6 inches above flood rim of sink(904 OPSe) 2.Provide minimum 30 inch wide finish clear floor space for master water closet.( 407 OPSe) 3.Fasten master shower enclosure to framing every 8 inches on verticle flanges using roofing nails or pan head screws.(31 0, 314 OPSe) corrections complete Post and Beam Framing Inspection Rough Mechanical Framing Inspection Rough Plumbing Framing Inspection 02/02120 I 0 NOK RWC 02/02/20 I 0 OK RWC 02/03120 I 0 OK BAR 02/03120 I 0 OK CJC 02/03120 I 0 OK BAR 02/0412010 POK CJC 02/04120 I 0 OK RWC 02/04120 I 0 10 RWC 02/04120 I 0 OK RWC 02/04/2010 OK RWC 02/04/2010 POK SKG 02/04/20 I 0 OK RWC 3 of 4 ,!~~.....-'......!.... 1..-.. ... .: City of Springfield Building Permit & Inspection Summary 10/15/2010 2:01 :08PM Job #: COM2009-01778 225 Fifth Street 541-726-3753 Phone 541-726-3676 Fax Project Status: Deferred Payment Job Address: 3841 EST SPRINGFIELD Scope of Work: Single Family Residence Description of Work: Single family residence -***********DP A ********** Rough Plumbing Wall Insulation inspectioon completed 2/8/20 I 0 Framing Inspection provide vapior barrior letter inspectioon completed 2/8/2010 Electric Service Water Line Sanitary Sewer Line Water Line Final Plumbing hold downs complete Called Sub Storm Sewer Line Final Electric Left correction notice: I.Please complete storm. sewer connection to building.(31 0 OPSe) 2.Relocate pressure reducing valve to above ground location.(608.20PSe) 3.Secure dishwasher to countertop.(31 0 OPSe) 4.Provide two seismic water heater straps, one within top 1/3 of tank and one within bottom 1/3 oftank.(508 OPSe) Around building O!,- 02/05/20 I 0 OK SKG 02/09/20 I 0 POK RWC 02/09/20 I 0 OK RWC 03/24/20 I 0 OK GAD 05/13/2010 CWO! SKG 05/13/2010 OK SKG 06/22/20 I 0 OK SKG 06/22/20 I 0 NOK SKG 06/22/2010 06/29/20 I 0 POK NR SKG GAD 4 of 4