Loading...
HomeMy WebLinkAboutPermit Building 2010-10-18 ii~ 10/18/2010 City of Springfield 10:35:14AM Building Permit & Inspection Summary Job #: COM2010-00754 225 Fifth Street 541-726-3753 Phone Job Address: 600 HAYDEN BRIDGE WAY Springfield 541-726-3676 Fax Scope of Work: Kitchen Project Status: OK to Issue Description of Work: Kitchen remodel Owner & Contractor(s) Name Address City. State, Zip Phone CON ESCHENBACHER HOMES INC 1574 COBURG RD EUGENE OR 97401 541-937-2636 ELC HOME COMFORT HEATING & AIR INC PO BOX 24205 EUGENE OR 97402 (541) 345-283 FIR OMLID & SWINNEY FIRE PROTECTIO 157 S 47TH STREET SPRINGFIELD OR 97478 541-741-1775 OWN INTERNATIONAL CHURCH OF THE FO 600 HAYDEN BRIDGE WA SPRINGFIELD OR 97477 541-726-8449 Valuation of Proiect Date Occupancy Construction Type Cost Per Su Ft Su Ftl! Valuation Calculated Staff EstiIrulte EstiIrulte $ 1.00 60,000.00 $60,000.00 2010/06/10 DJB $60,000.00 Fees Paid Description Amount Paid Date Paid Receipt # Plan Review Comm/IndlPublic $334.07 06/10/2010 3201000000000000293 Penn Serv/Fdr 200 amps or less $81.00 07/07/2010 3201000000000000397 Add, Alter, Extend Circ $55.00 07/07/20 I 0 3201000000000000397 Add, Alter, Extend Circ Ea Add $54.00 07/07/2010 3201000000000000397 + 12% State Surcharge $22.80 07/07/2010 3201000000000000397 + 5% Technology Fee $9.50 07/07/2010 3201000000000000397 FLS Safety Systems Review $120.00 08/05/2010 2201000000000000928 ***+ 10% Administrative Fee*** $12.00 . 08/05/2010 2201000000000000928 Total Amount Paid $688.37 Plans Reviewed Department Received Due Date Completed Result Reviewer Comments Planning Review 06/15/20 I 0 06/15/2010 APP EMM Interior remodel only. Needs Final Site Inspection for DRC2009-00038 for addition of this room. Please call Andy Limbird at (541) 726-3784. PLEASE GIVE 48 HOURS NOTICE. lof5 iiE~ City of Springfield Building Permit & Inspection Summary 10/18/2010 10:35:14AM Job #: COM2010-00754 225 Fifth Street 541-726-3753 Phone 541-726-3676 Fax Project Status: OK to Issue Fire Department Review 06/15/20 I 0 Structural Review Structural Review 06/15/20 I 0 07/13/2010 Job Address: 600 HAYDEN BRIDGE WAY Springfield Scope of Work: Kitchen Description of Work: Kitchen remodel 06/18/2010 APP GRG Plans Review: church kitchen remodel. Job #COM2010-00754. Occupancy Classifcation: A-2. Construction Type: V-B. Plans reviewed under the 2007 Springfield Fire Code and 2007 Oregon Structural Specialty Code. Provide fire extinguishers with a minimum rating of 40-B within 30 feet of travel distance of the accessory kitchen area. The top of the extinguisher( s) shall be between 3 and 5 feet above finished floor (2007 Springfield Fire Code 906/NFPA 10, A.5.4.1.3). Provide a letter to Springfield Fire Marshal Al Gerard verifying that the non-commercial kitchen appliances will be used for heating or occasional preparation of foods and not be used for prepping offoods producing grease laden vapors meeting Oregon Mechanical Specialty Code Interpretation 507.2.3. The letter shall be received and approved prior to final occupancy. . Completed I st Plan Review Received mechanical specifications for Type I commercial kitchen hood, but missing submittal of fire suppression system plans for Type I hood. Also, received incomplete site plan with incomplete specifications for accessible parking. 06/22/2010 WE 07/13/2010 WE KLK KLK . 20f5 '1~.""'!.""''''.''~'''...'' Wit. ' , ... . 11 . . , .....""'..."... . .1 City of Springfield Building Permit & Inspection Summary 10/18/2010 1O:35:14AM Job #: COM2010-00754 225 Fifth Street 541-726-3753 Phone 541-726-3676 Fax Job Address: 600 HAYDEN BRIDGE WAY Scope of Work: Kitchen Description of Work: Kitchen remodel Project Status: OK to Issue Structural Review 07/14/2010 07/14/2010 WE KLK Structural Review 07/20/20 I 0 07/20/2010 WE KLK Fire Department Review 07/20/20 I 0 07/20/2010 APP GRG Springfield Left phone message for architect, Rodd Hansen, to provide engineering calculations and specifications corresponding to the structural changes to the;kitchen area- new footings, columns and beams (is well as new footing, column, beam and truss connections for all lateral and verticalioads. Reviewed beam calc. and footing calc. from architect. Per phone call with architect, Architect to provide 1) structural design criteria and 2) a wet-signature stamped letter stating that there are not any lateralioads imposed on the new columns, beams and footings. Plans Review: Installation of Type I hood, rated shaft and restaurant type exhaust fan for kitchen remodel. Job #COM2010-00754. Contractor: HCH Mechanical. Plans Reviewed under the 2007 Springfield Fire Code, 2007 Oregon Mechanical Specialty Code. This deferred submittal shows the proposed installation of a Captive Aire roof mounted restaurant exhaust fan listed as meeting UL705 and UL762 standards; a Captive Aire model BD-2 hood and plenum system and a steel duct shaft surrounded by 3M 1 hour rated fire wrap except for the 16 inch space below the ceiling which is sheet rocked. Plans appear to meet fire code requirements. 30f5 8~r.~I..-_...~... Wit.. , . , .___". .___.. _ 1 City of Springfield Building Permit & Inspection Summary 10/18/2010 10:35:14AM Job #: COM2010-00754 225 Fifth Street 541-726-3753 Phone 541-726-3676 Fax Project Status: OK to Issue Job Address: 600 HAYDEN BRIDGE WAY Scope of Work: Kitchen Description of Work: Kitchen remodel Fire Department Review 07/29/20 I 0 APP GRG 07/29/20 I 0 Structural Review 08/03/20 I 0 08/03/2010 WI KLK Structural Review 08/06/20 I 0 08/06/2010 APP KLK Springfield Plans Review: Commercial Kitchen Hood and Duct Fire Suppression System. Job #COM201O-00754. Designer: Steve Francalancia/Chuck Harper. Contractor: Omlid and Swinney Fire Protection. Plans reviewed under the 2007 Springfield Fire Code, 2002 edition ofNFP A 17 A Standard for Wet Chemical Extinguishing Systems and 2004 edition ofNFPA 96, Standard for Ventilation Control and Fire Protection of Conunercial Cooking Operations. This submittal is for the protection of a newly installed Type I hood and a commercial applicance featuring a combined 6 burner range and small griddle. The kitchen suppression system is an Amerex KP275 system. It feeds a 16416 duct nozzle (I flow point) protecting the duct (less than 50 perimeter inches); an 11982 nozzle for the five foot long plenum (I flow point), a 14178 nozzle protecting 4 burners (2 flow points); an 11982 nozzle protecting the other two burners; and an 11982 nozzle protecting the griddle. Plans appear to meet code requirements. Received letter from the architect confirming structural changes to the kitchen effect gravity loads only. There are not any lateral loads imposed on the effected. columns, beams and footings. WI: Public Works Provide signed electrical permit application. 40f5 225 Fifth Street 541-726-3753 Phone 541-726-3676 Fax Project Status: OK to Issue Public Works Review 07/30/2010 Inspections Final Site Plan Framing Inspection Drywall Ceiling Grid Fire Dept Kitchen Supp System Fire Department Final Final Building Underfloor Plumbing Rough Plumbing . Final Plumbing Rough Mechanical Final Mechanical Rough Electric Final Electric Electric Service City of Springfield Building Permit & Inspection Summary Job Address: 600 HAYDEN BRIDGE WAY Scope of Work: Kitchen Description of Work: Kitchen remodel 08/06/20 I 0 APP EW 10/18/2010 1O:35:14AM Job #: COM2010-00754 Springfield PW received this application on.7/30/2010. SDC Worksheet is attached Inspections Conducted Comments Call Andy Limbird at (541) 726-3784 for Final Site Inspection of Fireside Room before Final Building Inspection at (541) 726-3784. Please give 48 hours notice. Date Result Called Sub 07/26/20 I 0 50f5 Inspector EMM OK GAD