Loading...
HomeMy WebLinkAboutMiscellaneous Compliance Report 2010-9-24 ., liTHE IBUILDING IQ~P~RTt1ENI~J..L..~ Exterior Wall Envelope Self-Certification Form , I, S\W\.~t-\C-J\l'v\ ~,^",~s L-U . arT) the general contractororthe owner-builder at the following address: '." f6a tA'\ 6A-'\:S 1)R- Street Add ress ~f\L\ Nt A1e..>.? d- City 2QJD ~ OO~ l C1 Permit# o To conform to the 2008 Oregon Residential Specialty Code (ORSC), Section R703.1.1, I am notifying the. building official that I am aware of the exterior wall envelope requirements of R703.1.1, and hereby certify that the components of the exterior wall envelope have been installed in accordance with the code requirements:'[Section R703.1.1 is provided for reference on the reverse side of this form.] Signat r q --~1~1 b Date ,. ;\~ ~.: ~.' ) f' ~ . ,',' ;, \ ':\Jfz~> . .,,'" '. ". . . ;.: ~~". '.\' . -; ".~ '1.~ "' t.' .J \ .'. . . ~ ~:. .~. " '.. ......... :i4~~- ..",'~', '~~i~;. ...."~,, . '~"'.;,..f, ~j..:" (~~-: t... '.. ... . o .~~ Revised: 2/8/2010, '.," . ".. t . . , . Excerpt from 2008 Oregon Residential Specialty Code Section R703, Exterior Covering: R703.1.1 Exterior Wall Envelope. To promote builCling durability, the exterior wall envelope shall be installed in a manner that water that enters the assembly can drain to the exterior. The envelope' shall consist of an exterior veneer, a water-resistive barrier as required in R703.2, a minimum 1/8 inch space between the water-resistive barrier and the exterior veneer. and integrated flashings as required in R703.8. The required space shall be formed by the use of any non-corrodible furring strip, drainage mat or drainage board. The envelope shall provide proper integration.offlashings. . with th~ water-resistive barrier, the space provided and the exterior-veneer. These components, in. , conjunction, shall provide a means of draining water that enters the assembiy to the exterior. ' ..../ '. \ o i~l . I f~ !t/f' ~ "Ii' . I. 11J ;', Exceptions: [ . :"".'. " 1. A space is not required where the exterior veneer is installed over a water-resistive barrier complying with section R703.2 which is manufactured in a m~nner to enhance drainage ,and meets the 75% drainage efficiency requirement of ASTM E2273 or other recognized national standards. . A space is not required where window sills are equipped wi,th pan flashings.which drain to the exterior surface of the veneer in a through wall fashion: All pan'flashings shall be detailed within the construction documents and shall be of either a self-adhering membrane complying with AAMA 711-07 or of an approved corrosion-resistant material or a combination thereof. Self-adhering membranes e~tending to the exterior. surface of the veneer shall be concealed with trims or other measures to protect from sunlight. .- A space is not required where the exterior veneer is manufactured in a manner to enhance drainage and meets the 75% drainage efficiency requirements of ASTM E2273 or other recognized national standards and is installed over a water resistive barrier complying with_ section R703.2. A space is not required where the exterior veneer is matching an existing ext"erior finish as i.n additions, alterations, or repairs. A water-resist~nt exterior wall envelope shall not be required over concrete or masonry walls designed in accordance with Chapter 6 and flashed according to section R703.7 or. R703.8. Compliance with ~he requirements for a means of drainage, and, the requirements of ' Section R703.2 and Section R703.8. shall not be required for an exterior wall'envelope that . " . I . has been demonstrated to resist wind-driven rain through testing of the exterior wall . envelope, including joints, p~netrations and intersections with dissimilar ~aterials, in accordance with ASTM E 331' under the following conditions: , 6.1. Exterior wall envelope test assemblies shall include at least one opening. one cohtrol joint, one wall/eave interface and one wall sill. All tested openings and penetrations shall be representative of the intended end-use config4ration. Exterior wall envelope test assemblies shall be at least 4 feet by 8 feet in size. Exterior wall assemblies shall be tested at a minimum differential pressure of 6.24 pounds per square foot. 6.4. Exterior wall envelope assemblies shall be subjected to a 'minimum test exposure duration of 2 hours. \; , The exterior wall envelope design shall be considered to resist wind-driven rain where the results of the testing indicate that water did not penetrate: control joints in the exterior . . " :~;;::;:'=~~'::.-::::'::~:" .,,"'"" ,,,_,,,, ":"'''''ct''"' ., . . " ,; ";;'.. ~~~j : 'l. , ., ,;:;~:~/~j;;1{~~ . i\j~{-- .1" - 1 '. ~ r."oo \. . ~~ 'w., "." ,~: ~... 2. , .~ 3. jo'" fi 4. 5. 6. I 6.2. 63. " .....:.,...- ~