Exterior Wall Envelope
Self-Certification Form
, I, S\W\.~t-\C-J\l'v\ ~,^",~s L-U . arT) the general contractororthe
owner-builder at the following address: '."
f6a tA'\ 6A-'\:S 1)R-
Street Add ress
~f\L\ Nt A1e..>.? d-
City
2QJD ~ OO~ l C1
Permit#
o
To conform to the 2008 Oregon Residential Specialty Code (ORSC), Section
R703.1.1, I am notifying the. building official that I am aware of the exterior wall
envelope requirements of R703.1.1, and hereby certify that the components of
the exterior wall envelope have been installed in accordance with the code
requirements:'[Section R703.1.1 is provided for reference on the reverse side of
this form.]
Signat r
q --~1~1 b
Date
,.
;\~ ~.: ~.'
) f'
~
. ,',' ;,
\ ':\Jfz~>
. .,,'"
'. ".
. . ;.: ~~". '.\' .
-; ".~ '1.~ "' t.'
.J
\ .'.
. .
~ ~:.
.~. " '..
.........
:i4~~-
..",'~',
'~~i~;.
...."~,,
. '~"'.;,..f,
~j..:" (~~-:
t... '..
... .
o
.~~
Revised: 2/8/2010,
'.," .
"..
t
. .
, .
Excerpt from 2008 Oregon Residential Specialty Code Section R703, Exterior Covering:
R703.1.1 Exterior Wall Envelope. To promote builCling durability, the exterior wall envelope shall
be installed in a manner that water that enters the assembly can drain to the exterior. The envelope'
shall consist of an exterior veneer, a water-resistive barrier as required in R703.2, a minimum 1/8
inch space between the water-resistive barrier and the exterior veneer. and integrated flashings as
required in R703.8. The required space shall be formed by the use of any non-corrodible furring
strip, drainage mat or drainage board. The envelope shall provide proper integration.offlashings. .
with th~ water-resistive barrier, the space provided and the exterior-veneer. These components, in. ,
conjunction, shall provide a means of draining water that enters the assembiy to the exterior. '
..../
'.
\
o
i~l . I
f~ !t/f' ~
"Ii' .
I.
11J
;',
Exceptions:
[
. :"".'.
"
1.
A space is not required where the exterior veneer is installed over a water-resistive barrier
complying with section R703.2 which is manufactured in a m~nner to enhance drainage ,and
meets the 75% drainage efficiency requirement of ASTM E2273 or other recognized
national standards. .
A space is not required where window sills are equipped wi,th pan flashings.which drain to
the exterior surface of the veneer in a through wall fashion: All pan'flashings shall be
detailed within the construction documents and shall be of either a self-adhering
membrane complying with AAMA 711-07 or of an approved corrosion-resistant material or
a combination thereof. Self-adhering membranes e~tending to the exterior. surface of the
veneer shall be concealed with trims or other measures to protect from sunlight. .-
A space is not required where the exterior veneer is manufactured in a manner to enhance
drainage and meets the 75% drainage efficiency requirements of ASTM E2273 or other
recognized national standards and is installed over a water resistive barrier complying with_
section R703.2.
A space is not required where the exterior veneer is matching an existing ext"erior finish as
i.n additions, alterations, or repairs.
A water-resist~nt exterior wall envelope shall not be required over concrete or masonry
walls designed in accordance with Chapter 6 and flashed according to section R703.7 or.
R703.8.
Compliance with ~he requirements for a means of drainage, and, the requirements of '
Section R703.2 and Section R703.8. shall not be required for an exterior wall'envelope that .
" . I .
has been demonstrated to resist wind-driven rain through testing of the exterior wall
. envelope, including joints, p~netrations and intersections with dissimilar ~aterials, in
accordance with ASTM E 331' under the following conditions:
,
6.1. Exterior wall envelope test assemblies shall include at least one opening. one cohtrol
joint, one wall/eave interface and one wall sill. All tested openings and penetrations
shall be representative of the intended end-use config4ration.
Exterior wall envelope test assemblies shall be at least 4 feet by 8 feet in size.
Exterior wall assemblies shall be tested at a minimum differential pressure of 6.24
pounds per square foot.
6.4. Exterior wall envelope assemblies shall be subjected to a 'minimum test exposure
duration of 2 hours. \; ,
The exterior wall envelope design shall be considered to resist wind-driven rain where the
results of the testing indicate that water did not penetrate: control joints in the exterior .
. "
:~;;::;:'=~~'::.-::::'::~:" .,,"'"" ,,,_,,,, ":"'''''ct''"' ., . . " ,; ";;'.. ~~~j
: 'l. , .,
,;:;~:~/~j;;1{~~
. i\j~{--
.1" - 1 '. ~
r."oo \. . ~~
'w., "."
,~: ~...
2.
,
.~
3.
jo'"
fi
4.
5.
6.
I
6.2.
63.
"
.....:.,...- ~