Exterior ~all Envelope
Self-Certification Form
4878 vA" 5T
Street Address
~PR-'~le..t cl
City
Co H 2010 - 0060D
Permit#
To conform to the 2008 Oregon Residential Specialty Code (ORSC), Section .1,
R703.1.1, I am notifying the building official that I am aware of the exterior wall
envelope requirements of R703.1.1, and hereby certify that the components of
the exterior wall envelope have been installed in accordance with the code
requirements. [Section R703.1.1 is provided for reference on the reverse side of
this form.]
S;g",~
J~ -/6 -10
Date
Revised: 2/8/2010
I
\
... .....,
- \, ~"'"1
q;6j
k
Excerpt from 2008 Oregon Residential Specialty Code Section R703, Exterior Covering:
R703.1.1 Exterior Wall Envelope. To promote building durability, the exterior wall envelope shall
be installed in a manner that water that enters the assembly can drain to the exterior. The envelope
shall consist of an exterior veneer, a water-resistive barrier as required in R703.2, a minimum 1/8
inch space between the water-resistive barrier and the exterior veneer, and integrated flashings as
required in R703.8. The required space shall be formed by the use of any non-corrodible furring
strip, drainage mat or drainage board..The.envelope shall provide'proper integration'of flashings " '....
- ~. . H " . . ~. oJ .' ,.' - . ~ '. .' " . '.
with the water-resistive barrier, the space' provided "and the exterior veneer. These components, in
.,
conjunction, shall provide a means of draining water that enters the assembly to the exterior.
Exceptions:
.', ~t ,~. '. ""
" . -~. ...).
A space is not required where the exterior veneer is installed over a water-resistive barrier
complying with section R703.2 which is manufactured in a manner to enhance drainage and
meets the 75% drainage efficiency requirement of ASTM E2273 or other recbg~iz~d . (
national standards. ..v.. . .. ......... -.
A space is not required where window sills are equipped with pan flashings which drain to
the exterior surface of the veneer in a through wall fashi,on: ~II pan flashings shall be';-_\ :".' "
detailed within the construction documents and shall be of either a self-adhering' ., - .
membrane complying with AAMA 711-07 or of an approved corrosion-resistant material or
a combination thereof. Self-adhering membranes extending to the exterior surface of the
veneer shall be concealed with trims or other measures to protect from sunlight.
3. A space is not required where the exterior veneer is manufactured in a manner to enhance
drainage and meets the 75% drainage efficiency requirements of ASTM E2273 or other
recognized national standards and is installed over a water resistive barrier complying with
section R703.2.
A space is not required where. the exterior veneer is matching an existing exterior finish as
in additions, alterations, or repairs.
5. A water-resistant exterior wall envelope shall not be required over concrete or masonry
walls designed in accordance with Chapter 6 and flashed according to section R703.7 or
R703.8.
Compliance with the requirements for a means of drainage, and the requirements of
,
Section R703.2 and Section R703.8, shall not be required for an'ext~rior wall envelope that
has been demonstrated to resist wind-driven rain through testing of the',exterior~iNal", _. \
... _~r'" ,
envelope, including joints, penetrations and intersections with dissimilar materials, in -
accordance with ASTM E 331 under the following conditions: ..,
6.1. Exterior wall envelope test assemblies shall include at least one opening;-ore control
joint, one wall/eave interface and one wall sill. All tested openings and penetrations . .
shall be representative of the intended end-use configuration.
Exterior wall envelope test assemblies shall be at least 4 feet by 8 feet in size.
Exterior wall assemblies shall be tested at a minimum differential pressure of 6.24
pounds per square foot.
6.4. Exterior wall envelope assemblies shall be subjected to a minimum test exposure
duration of 2 hours.
The exterior wall envelope design shall be considered to resist wind-driven rain where the
results of the testing indicate that water did not penetrate: control joints in the exterior
wall envelope; joints at the perimeter of openings penetration; or intersections of
terminations with dissimilar materials.