Loading...
HomeMy WebLinkAboutMiscellaneous Compliance Report 2010-10-16 (2) 4&378 r1rl-lE .;; 'IBUILDING ,DEPARTMENT. LLC .,..c"J-.----.--.-------..-. Exterior ~all Envelope Self-Certification Form 4878 vA" 5T Street Address ~PR-'~le..t cl City Co H 2010 - 0060D Permit# To conform to the 2008 Oregon Residential Specialty Code (ORSC), Section .1, R703.1.1, I am notifying the building official that I am aware of the exterior wall envelope requirements of R703.1.1, and hereby certify that the components of the exterior wall envelope have been installed in accordance with the code requirements. [Section R703.1.1 is provided for reference on the reverse side of this form.] S;g",~ J~ -/6 -10 Date Revised: 2/8/2010 I \ ... ....., - \, ~"'"1 q;6j k Excerpt from 2008 Oregon Residential Specialty Code Section R703, Exterior Covering: R703.1.1 Exterior Wall Envelope. To promote building durability, the exterior wall envelope shall be installed in a manner that water that enters the assembly can drain to the exterior. The envelope shall consist of an exterior veneer, a water-resistive barrier as required in R703.2, a minimum 1/8 inch space between the water-resistive barrier and the exterior veneer, and integrated flashings as required in R703.8. The required space shall be formed by the use of any non-corrodible furring strip, drainage mat or drainage board..The.envelope shall provide'proper integration'of flashings " '.... - ~. . H " . . ~. oJ .' ,.' - . ~ '. .' " . '. with the water-resistive barrier, the space' provided "and the exterior veneer. These components, in ., conjunction, shall provide a means of draining water that enters the assembly to the exterior. Exceptions: .', ~t ,~. '. "" " . -~. ...). A space is not required where the exterior veneer is installed over a water-resistive barrier complying with section R703.2 which is manufactured in a manner to enhance drainage and meets the 75% drainage efficiency requirement of ASTM E2273 or other recbg~iz~d . ( national standards. ..v.. . .. ......... -. A space is not required where window sills are equipped with pan flashings which drain to the exterior surface of the veneer in a through wall fashi,on: ~II pan flashings shall be';-_\ :".' " detailed within the construction documents and shall be of either a self-adhering' ., - . membrane complying with AAMA 711-07 or of an approved corrosion-resistant material or a combination thereof. Self-adhering membranes extending to the exterior surface of the veneer shall be concealed with trims or other measures to protect from sunlight. 3. A space is not required where the exterior veneer is manufactured in a manner to enhance drainage and meets the 75% drainage efficiency requirements of ASTM E2273 or other recognized national standards and is installed over a water resistive barrier complying with section R703.2. A space is not required where. the exterior veneer is matching an existing exterior finish as in additions, alterations, or repairs. 5. A water-resistant exterior wall envelope shall not be required over concrete or masonry walls designed in accordance with Chapter 6 and flashed according to section R703.7 or R703.8. Compliance with the requirements for a means of drainage, and the requirements of , Section R703.2 and Section R703.8, shall not be required for an'ext~rior wall envelope that has been demonstrated to resist wind-driven rain through testing of the',exterior~iNal", _. \ ... _~r'" , envelope, including joints, penetrations and intersections with dissimilar materials, in - accordance with ASTM E 331 under the following conditions: .., 6.1. Exterior wall envelope test assemblies shall include at least one opening;-ore control joint, one wall/eave interface and one wall sill. All tested openings and penetrations . . shall be representative of the intended end-use configuration. Exterior wall envelope test assemblies shall be at least 4 feet by 8 feet in size. Exterior wall assemblies shall be tested at a minimum differential pressure of 6.24 pounds per square foot. 6.4. Exterior wall envelope assemblies shall be subjected to a minimum test exposure duration of 2 hours. The exterior wall envelope design shall be considered to resist wind-driven rain where the results of the testing indicate that water did not penetrate: control joints in the exterior wall envelope; joints at the perimeter of openings penetration; or intersections of terminations with dissimilar materials. 1. 2. 4. 6. 6.2. 6.3.