Loading...
HomeMy WebLinkAboutMiscellaneous Compliance Report 2010-10-15 (2) .~, . .' i FljHE IBUILDING ,!DEPARTMENT. LLC .t.o'J- . .-.--.......-.-.- "", Exterior Wall Envelope Self-Certification Form " v' , . I, ~ W c. l-t owner-buil~er at the following address: . am the general contractor or the i , Y/? i) Street Address l' , , " Permit# i; To conform to th,e 2008 Oregon Resi,dential Specialty Code (ORSC), Sectio,n R703.1.1, I am n'otifying the building official that I am aware of the ext!'!/ior wall" " envelope requirements Of R703.1.1,:iand hereby certify t~at the components of .. the exterior wall envelope have been installed in accordance with the code . . - .: \ ',,',' 'requirements. [Srctio,n R703.1.1 is provided for reference on the reverse;'side of' this form.] . ' . ;0 .t~:i \ .'; .~,; ~ ;~ :, v ~~;~.,~t~: :_~. ",;"d, '/8/20m - d " .' .. I' \ \ , ~: < '- l \ Excerpt from 2008 Oregon Residential Specialty Code Section R703, Exterior Covering: R703.1.1 Exterior Wall Envelope. JO promote builaing durability, the exterior wall envelope shall be installed in a manner that water that enters the assembly can drain to the exterior. The envelope shall consist of an exterior veneer, a water-resistive barrier as required in R703.2, a minimum 1/8 inch space between the water-resistive barrier and the exterior veneer, and integrated flashings as . required in R703.8. The required space shall be formed by the use of any non-corrodible furring strip, drainage mat or drainage board. The envelope shall provide proper integratiqn of flashings .' with the water-resistive barrier, the space provided and the exterior veneer. These'components, in conjunction, shall provide a means of draining water that enters the assembly to the exterior. Exceptions: 1. A space is not required where the exterior veneer is installed over a water-resistive barrier complying with section R703.2 which is manufactured in a manner to enhance drainage an~ m~ets the 75% drainage efficiency requirement of ASTM E2273 or other recognized national standards. A space is not required where window sills are equipped with pan flashings which drain to the exterior surface of the veneer in a through wall fashion: All pan flashings shall be detailed within the construction documents and shall be of either a self-adhering membrane complying with AAMA 711-07 or of an approved corrosion-resistant material or a combination thereof. Self-adhering membranes extending to the exterior surface of the veneer shall' be concealed with trims or other measures to protectfrom sunlight. A space is not required where the exterior veneer is manufactured in a manner to enhance drainage and meets the 75% drainage efficiency requirements of ASTM E2273 or other recognized national standards and is installed over a water resistive barrier complying with section R703.2. A space is not required where the exterior veneer is matching an existing exterior finish as in additions, alterations, or repairs. A water-resistant exterior wall envelope shall not be required over concrete or masonry 'walls designed in accordance with Chapter 6 and flashed according to section R703.7 or R703.8. Compliance with the requirements for a means of drainage, and the requirements of Section R703.2 and Section R703.8, shall not be required for an exterior wall envelope that . has been demonstrated to resist wind-driven rain through testing of the exterior wall envelope, including joints, penetrations and intersections with dissimilar materials 'in' '\.. - I accordance with ASTM E 331 under the following conditions: . 6.1. Exterior wall envelope test assemblies shall include at least one opening, one control joint, one wall/eave interface and one wall sill. All tested openings and penetrations shall be representative ofthe intended end-use configuration. 6.2. Exterior wall envelope test assemblies shall be at least 4 feet by 8 feet in size. 6.3. Exterior wall assemblies shall be tested at a minimum differential pressure of 6.24 pounds per square foot. 6.4. Exterior wall envelope assemblies shall be subjected to a minimum test exposure duration of 2 hours. The exterior wall envelope design shall be considered to resist wind-driven rain where the results of the testing indicate that water did not penetrate: control joints in the exterior wall env.~lope; joints at the perimeter of openings penetration; or intersections of ~ terminations with. dissill)i1ar materials. .J 2. 3. 4. 5. 6. \ \