HomeMy WebLinkAboutMiscellaneous Compliance Report 2010-10-15 (2)
.~, .
.'
i FljHE
IBUILDING
,!DEPARTMENT. LLC
.t.o'J- . .-.--.......-.-.-
"",
Exterior Wall Envelope
Self-Certification Form
"
v' ,
.
I, ~ W c. l-t
owner-buil~er at the following address:
. am the general contractor or the
i
,
Y/? i)
Street Address
l'
,
,
"
Permit#
i;
To conform to th,e 2008 Oregon Resi,dential Specialty Code (ORSC), Sectio,n
R703.1.1, I am n'otifying the building official that I am aware of the ext!'!/ior wall"
" envelope requirements Of R703.1.1,:iand hereby certify t~at the components of ..
the exterior wall envelope have been installed in accordance with the code
. . - .: \ ',,','
'requirements. [Srctio,n R703.1.1 is provided for reference on the reverse;'side of'
this form.] . ' .
;0
.t~:i
\ .';
.~,;
~ ;~
:,
v ~~;~.,~t~: :_~.
",;"d, '/8/20m - d
"
.'
..
I'
\
\
, ~:
<
'-
l
\
Excerpt from 2008 Oregon Residential Specialty Code Section R703, Exterior Covering:
R703.1.1 Exterior Wall Envelope. JO promote builaing durability, the exterior wall envelope shall
be installed in a manner that water that enters the assembly can drain to the exterior. The envelope
shall consist of an exterior veneer, a water-resistive barrier as required in R703.2, a minimum 1/8
inch space between the water-resistive barrier and the exterior veneer, and integrated flashings as .
required in R703.8. The required space shall be formed by the use of any non-corrodible furring
strip, drainage mat or drainage board. The envelope shall provide proper integratiqn of flashings .'
with the water-resistive barrier, the space provided and the exterior veneer. These'components, in
conjunction, shall provide a means of draining water that enters the assembly to the exterior.
Exceptions:
1.
A space is not required where the exterior veneer is installed over a water-resistive barrier
complying with section R703.2 which is manufactured in a manner to enhance drainage an~
m~ets the 75% drainage efficiency requirement of ASTM E2273 or other recognized
national standards.
A space is not required where window sills are equipped with pan flashings which drain to
the exterior surface of the veneer in a through wall fashion: All pan flashings shall be
detailed within the construction documents and shall be of either a self-adhering
membrane complying with AAMA 711-07 or of an approved corrosion-resistant material or
a combination thereof. Self-adhering membranes extending to the exterior surface of the
veneer shall' be concealed with trims or other measures to protectfrom sunlight.
A space is not required where the exterior veneer is manufactured in a manner to enhance
drainage and meets the 75% drainage efficiency requirements of ASTM E2273 or other
recognized national standards and is installed over a water resistive barrier complying with
section R703.2.
A space is not required where the exterior veneer is matching an existing exterior finish as
in additions, alterations, or repairs.
A water-resistant exterior wall envelope shall not be required over concrete or masonry
'walls designed in accordance with Chapter 6 and flashed according to section R703.7 or
R703.8.
Compliance with the requirements for a means of drainage, and the requirements of
Section R703.2 and Section R703.8, shall not be required for an exterior wall envelope that
. has been demonstrated to resist wind-driven rain through testing of the exterior wall
envelope, including joints, penetrations and intersections with dissimilar materials 'in'
'\.. - I
accordance with ASTM E 331 under the following conditions: .
6.1. Exterior wall envelope test assemblies shall include at least one opening, one control
joint, one wall/eave interface and one wall sill. All tested openings and penetrations
shall be representative ofthe intended end-use configuration.
6.2. Exterior wall envelope test assemblies shall be at least 4 feet by 8 feet in size.
6.3. Exterior wall assemblies shall be tested at a minimum differential pressure of 6.24
pounds per square foot.
6.4. Exterior wall envelope assemblies shall be subjected to a minimum test exposure
duration of 2 hours.
The exterior wall envelope design shall be considered to resist wind-driven rain where the
results of the testing indicate that water did not penetrate: control joints in the exterior
wall env.~lope; joints at the perimeter of openings penetration; or intersections of
~ terminations with. dissill)i1ar materials.