HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2010-9-27
&fEt
~
Page 1 of 1
!ESTIIIGK III\r[GIOII, IiIC
Geoled1ricaI & Ca1sbudicr1 SeM:es
Daily Field Report
Client:
Mr, Dennis Boyd
HVAC & Metals Institute
2379 NE 178th Ave,
Portland, Oregon 97230
Project: Sheet Metal Institute
1887 Laura Street
Springfield, Oregon
Date:
Project No.:
Report No.:
Inspector:
10 No.:
09-27-10
2107115
E-26722
A. Fenstermacher
5258882-49
ICC
Inspection of: Epoxy Dowels
Contractor: McKenzie Commercial
Continuous Inspection: 0
Periodic Inspection: 0
Performed continuous inspection during the installation of sixteen (16) 3/4" x 12"
vertical anchors into existing footing ior column anchorage at the west side of the main
entrance, four (4) locations, four (4) anchors at each location, Prior to installation, the
predrilled holes were cleaned with compressed air and a brush, Verified minimum
embedment of 8" except as follows: ':two (2) at 6", south column; two (2) at 6", south
center column; one (1) at 6", north center column; one (1) at 6", north column, Anchors
were secured with Hilti Hit RE50!}SD epoxy (ICC - ES,ESR 2322/ expiration date
07/2011), . Note; EOR'approval is needed for reduced embedment depth,; ..
(' "'. ~.l'" ~ :....',.,"1 ~ ,,~ }" .,; --.11" . .C':l '.. ~'...' . '.. ,. , ,.. . -: c...~ .
To the best of our knowledge, the work inspected was in accordance with plans dated
06-21-10 and applicable workmanship provisions ofthe I.B,C" except if noted above,
Reviewed By:
fh,i.~-.
Michael L. ~eC
Technical Manager
c:
Robertson Sherwood Architects - Randy Nishimura (email)
McKenzie Commercial - Bill Henderson (email)
City of Springfield .
MLM:sc
.~~"7 ;. :,,7-f :Y. . - ::'.;-~.r r:, ";:,,~, , .
-,
'I'
"J' .- ',-",
[;.::; !-,. "'~ -:,." ,..,....
This report 8nd/~r enclosed test data is the confidential property of the client to whom it is addressed and pertains to the
specific J:!rocessand/or.material evaluated. As such! information contained herein shall not bs"reproduced in part or full
" and/or any pert thereof be disclosed without FEI Testing & Inspection, Inc. 's written authorization.
!
. 750 NWComeII A\I8rUl-CoovaIIis, Oregcln 97330 -phone (541) 757-4898 ,fax (541) 757-2991
29540 BAirportRJad '8Jgene, Oregori 97402 -phone (541) 684-3849 -fax (541) 684-3851
62979 NE PIaleau DriIie, Suite 3, Bend, ~ 97701 'phone(541) 382-4844' fax (541) 3824846
c:::> :;0