HomeMy WebLinkAboutPermit Building 2001-1-18
.,4 ".
Job# 00-01353-01
-<(
Page 1 of 5
TRANS#:Ol-0004262
DATE:JAN 18 2001
AMT RECD:2 $ 333,96
i'H"Hi.jI1F'
,-J 1..w_1t
CASHIER: 061
225 North Fifth Street
Springfield, OR 97477
RESIDENTIAL PERMIT
City Of Springfield
, Community Services Division
Building Safety
Job Number: 00-01353-01
Office: 726-3759
Inspection Line: 726-3769
location Of Proposed Site: 3562 Osprey Dr Spr
Assessors Map#: 17021943
lot: 170 Block: Addition:
Owner:
Address:
Tax lot #: 08300
Subdivision:Ambleside Meadows
Dukes & Dukes Construction Co
Po Box 71095
Phone Number: 541-747-3130
City/State/Zip: Eugene, OR 97401
New . Value: $147,179
Scope Of Work: Single Family Residence
Contractor Type
General Contr
Electrical Contr
Electrical Contr
Mechanical Contr
Plumbing Contr
Quad Area:
# Of Units:
Constr. Type:
Water Heater:
Same As 2381 35th S~reet
Contractor
Dukes & Dukes Construction Co
Po Box 71095, Eugene, OR 97401
Eastside Electric Inc 117770
38253 Boscage Ln, Springfield, OR 97478
Registration #
65060
Expiration Date
3/16/2001
Phone
541-747-3130
10/4/2001
541-741-1499
Diversified Electronics 541-484-9078
PO BOX 40548, Springfield, OR
Comfort Flow Heating Co 460 NOTICE: 6/27/2001 541-726-0100
~~~;7~f~9~t Ste D, Springfield, OR THIS PERMIT SHALL EXPIRE IFTHEWORK
Don Lewis Plumbing 33076UTHORIZE61N&Y2lfu9 THIS PER~~~~ ~~~C?~r931
500 Greenfield Street, Eugene, OR 97404 COMMENCED OR IS ABANDONED FOR
_. n . . __ _ A\" """r-I'""'\I"n
MI....lluv...,nl.~III'-'-.
3RNC
1
(VN) Wood Frame
Gas
Office Use
land Use: Single Family Dwelling
Zoning Code: LDR
Bedrooms: 3
Range: Electric
# Of Buildings: 1
Occupancy Group: Dwelling
Heat Source: Forced Air Gas
Sq. Footage: 1608
._.......~I Jf""It. __ ___I_.......__......__..._..~_
1-\1 I CI'.J t ~V~\!."v.\.."'}~\. . = i~'.'V _v~\,.dil""''''' J-"'.-
To request an inspection call the 24 hour recording at 726-3769, ' All ifts~,e6tioriS!!reqlrEfst~a ro~f0refPr(i)'01On Utility
a,m. will be made the same working day, inspections requested aftEfrJ;otlA(j).::9.,~~fwlll:tl,efmaaejtlirelfdllowir1ig setforth
working day. in OAR 952-001-0010 through OAR 952-001-
R . d I f 0090. You mav obtain cODies of the rules by
eqUlre nspec Ions calling the center. (Note: the telephone
I Building nl, hnberforthe Oregon Utility Notification
- To be made after excavation but prior to setting fo.[JB~.ieris 1-8[;0-882.-2344).
-Install ground rod at footing, and call for inspection in conjuction with footing and/or foundation i
-After trenches are excavated, .
-After forms are erected but prior to concrete placement.
-Prior to floor insulation or decking.
Site
Verify Ground Rod
Footing
Foundation
Post and Beam
Floor Insulation
Ceiling Insulation
Shear Wall Nailing
Framing
Wall Insulation
Drywall
Final Building
Temporary Power
Rough Electrical
Electrical Service
Low Voltage
Final Electrical
Underfloor Plumbing
Underfloor Drain
Rough Plumbing
Water Line
Sanitary Sewer Line
Storm Sewer Line
Perimeter Foundation
Drains
Final Plumbing
Underfloor Mechanical
Rough Gas
Rough Mechanical
Gas Service
Final Gas
Final Mechanical
SW-Curbside
CC-Standard
.1 Job# 00-01353-01 I
Required Inspections
Building
,I
Page 2 of 5
I
- Prior to decking.
- Prior to cover.
- Before covering sheathing with finish materials.
- Prior to cover.
- Prior to Cover
-Prior to taping.
- When all required inspections have been approved and the building is complete.
I Electrical I
-Approval required prior to SUB energizing pole.
- Prior to cover.
-Must be approved to obtain permanent power,
- When all electrical work is complete,
I Plumbing
- Prior to insulation or decking,
- Prior to cover or placement of concrete.
- Prior to cover.
- Prior to filling trench,
- Prior to filling trench,
- Prior to filling trench.
-After gravel and filter cloth is installed, but prior to backfill.
- When all plumbing work is complete.
I Mechanical
- Prior to insulation or decking,
- Prior to cover,
-After line is installed and line has been connected to a minimum of one appliance. Pressure tel
- When all gas work is complete,
- When all mechanical work is complete.
I Public Works 1
-After forms are erected but prior to placement of concrete
-After forms are erected but prior to placement of concrete
Street Improvement: Fully Improved
Curb Cut?0 Improvement Agr.?D
San Sewer Depth (Ft):6 ' 4
Storm Sewer Available? 0
Special Req.:
Security Required:
Bond Begin DateTime: 00/00/0000 00:00 AM
Special Instructions:
Other Utilities:
Project Supervisor:
Sidewalk Type:
Additional ROW?
Size Of Line (in):
Downspouts/Drains:
Enchroachment Permit:
San Sewer Tee (in):
Bond End DateTime:
Curbside - 5'
D
8
To Curb and Gutter
6
00/00/000000:00 AM
Types Of Warning Devices Reqd.
Zoning: LDR
FloodPlain? D Wetlands? D
Journal numbers
1: 2:
Comments:
Planner: Ruth Klein
Urban Growth Boundary?D
Quantity Of Fill:
Supplier:
Drainage:
Floodway FEMA: n/a
I Job# 00-01353-01 I
Overlay District:
# of Street Trees: 2
Page 3 of5
Land Use: Single Family Dwelling
Pave Driveway? 0
3:
Additional Requirements: ~DAP Required
Required Attachments:
Source Locn:
Material:
Glenwood Area? D
Construction Types:(VN) Wood Frame
Occupancy Groups:Dwelling
# Of Buildings: 1
# Of Bedrooms: 3
Handicap Access? D
-Area (Sq. Feet)
Main: 1608 Accessory500
Fee
Residential Plan Check
Additional Plan Check
Hourly Plan Review
Total Plan Check
Building Permit
Building Permit
State Surcharge For Building Permit
State Surcharge For Building Permit
Building Administrative Fee
Building Administrative Fee
Total Building
Wiring Footage 1,000 Sq Ft or Less
Wiring Footage Each Add'l 500 Sq Ft
Wiring Footage Each Add'l 500 Sq Ft
Temporary: 200 Amps or Less
Limited Energy - Residential
Limited Energy - Residential
State Surcharge - Electrical
State Surcharge - Electrical
State Surcharge - Electrical
State Surcharge - Electrical
Administrative Fee - Electrical
Administrative Fee - Electrical
Administrative Fee - Electrical
Administrative Fee - Electrical
Total Electrical
Flood Plain FEMA: n/a
Accessory Structure
# Of Stories: 2 Height (feet): 28
Current Units: Proposed Units:1
Census Code: New SF - detached
Total:2108
Paid On Receipt#
Plan Check
09/06/2000 3133
10/13/2000 3464
01/18/2001 4262
Value/Quantity
121,151
-234
3
Building
10/13/2000 3464
01/18/2001 4262
10/13/2000 3464
01/18/2001 4262
10/13/2000 3464
01/18/2001 4262
121,151
26,028
Electrical
01/11/2001 4238
01/11/2001 4238
01/18/2001 4262
10/13/2000 3464
01/08/2001 4195
01/11/2001 4238
10/13/2000 3464
01/08/2001 4195
01/11/2001 4238
01/18/2001 4262
10/13/2000 3464
01/08/2001 4195
01/11/2001 4238
01/18/2001 4262
1
3
1
1
1
1
Fee Amount
$313.63
$-233,60
$120,00
$200.03
$482,50
$179,50
$33.78
$12,57
$14.48
$5.39
$728.22
$85,00
$45,00
$15,00
$40,00
$20.00
$20.00
$2.80
$1.40
$10,50
$1.05
$1,20
$,60
$4,50
$.45
$247.50
Job# 00-01353-01 Page 4 of 5
Fee Paid On Receipt# Value/Quantity Fee Amount
Plumbing
Minimum Plumbing Permit Fee 10/13/2000 3464 $,00
Three Bathrooms 10/13/2000 3464 1 $192,50
State Surcharge - Plumbing 10/13/2000 3464 $13.48
Administrative Fee - Plumbing 10/13/2000 3464 $5,78
Total Plumbing $211.76
Mechanical
Hood and Exhaust 10/13/2000 3464 1 $4.50
One to Four Outlets 10/13/2000 3464 1 $2.00
Minimum Mechanical Permit 10/13/2000 3464 $,00
Administrative Fee - Mechanical 10/13/2000 3464 $,83
Less than 100,000 BTU 10/13/2000 3464 1 $6,00
Vent Fan to One Duct 10/13/2000 3464 4 $12,00
Dryer Vent 10/13/2000 3464 1 $3.00
Mechanical Issuance 10/13/2000 3464 $10.00
State Surcharge - Mechanical 10/13/2000 3464 $1,93
Total Mechanical $40.26
Public Works
New Sidewalk 10/13/2000 3464 60 $60,00
New Curbcut 10/13/2000 3464 1 $60.00
Total Public Works $120.00
System Development
Residential - Single Family - Storm 10/13/2000 3464 1,897 $455,16
Sanitary Sewer 10/13/2000 3464 23 $1,146.78
Residential Transportation 10/13/2000 3464 1 $507.82
Residential Sanitary MWMC 10/13/2000 3464 1 $285.91
Residential Improvement MWMC 10/13/2000 3464 1 $24,33
MWMC Administrative Fee 10/13/2000 3464 1 $10.00
SDC Administrative Fee 10/13/2000 3464 $121.47
Property Annexed 1997 10/13/2000 3464 1 $-,59
Total System Development $2,550.88
Willamalane SDC
S.F. Residence - Willamalane 10/13/2000 3464 1 $1,000,00
Total Willamalane SDC $1,000.00
Grand Total $5,098.65
Plan Check Type Checked By Date Completed
Initial Review-Res Lisa Hopper 09/11/2000
Engineering-Res Steve Templin 09/14/2000
Planning-Res Ruth Klein 09/19/2000
Structural-Res Wendy Stanley 09/18/2000
Structural-Res Don Moore 01/16/2001
Comment
NO OCCUPANCY UNTIL CITY ACCEPTS
INFRASTRUCTURE
Bonus room is not approved for sleeping
purposes.
r
.. iL
I Job# 00-01353-01 I Page 5 of 5
By signature, I state and agree, that I have carefully examined the completed application and do
hereby certify that all information hereon is true and correct, and I further certify that any and all work
performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of
the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made
of any structure without permission of the Community Services Division, Building Safety, I further
certify that only contractors and employees who are in compliance with ORS 701,055 will be used on
this project.
I further agree to ensure that all required inspections are requested at the proper time, that each
address is readable from the street, that the permit card is located at the front of the property, and the
approved set 0 -PJan~1I ~ the, site at all times during construction.
~.y---~_ ._ /-/g'''':O(
Si'Qriature ---. ~ Date