Loading...
HomeMy WebLinkAboutSpecial Inspection Field Test & Inspection Report 2010-6-3 City of Springfield Community Services Division 225 Fifth Street Springfield, OR 97477 Telephone: (541) 726-3759 Fax: (541) 726-3689 IPI,,:J-&~t ,-> -/0 Building Pem,it # Date . '2--~ \ V-!D.5k; A...;j"o Project Title 'LOO ,.)-\\-... "34-1'-' S?~ID Project Address Special Inspection and Testing To applicants of projects requiring special inspection or testing as per Section 1704 or the Oregon Structural Specialty Code. Please review the information below. When YOll have finished, acknowledge an understanding of the information by signing below, and return this form to the City. BEFORE A PERMIT CAN BE ISSUED: The owner or owner's representative. on the advice orthe responsible Project Engineer or Architect, shall complete, sign. and submit to the City for review and approval this form completed on both the front and back. The owner and General Contractor, where applicable, shall also acknowledge the following conditions applicable to Special Inspection and/or Testing, t. Contractor is responsible for proper notification for the Inspection or Testing of items listed. 2. Testing laboratory shall take appropriate samples and transport them to their laboratory for proper evaluation or testing. . Copies of all laboratory reports and inspections are to be sent to the City by the Testing Agency. 3. Special Inspection Agency is to submit names and qualifications of on-site Special Inspectors to the City for approval. 4. Special Inspector shall provide inspection rep0l1s to the building official ofa!1 inspection activities. 5. Contractor is 5csponsible to review the .City approved plans for additional inspection or ~esting requirements that may be noted. BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED: The Special Inspection Agency shall submil to .the Building Omcial a statement that all items requiring inspection have been fulfilled and reported and were to the best of the inspector's knowledge, in conformance with the approved plans, specifications and applicable workmanship provisions. Those items not tested and/or inspected'shall be noted in the statement. The report is to be submitted to the City prior to a request tor tinal inspections. ACKNOWLEDGEMENTS 6~ILN~e (p~qef f hUD !41 0 (--fl' er i?,J ~ I .,,-,-,r, "1 .. Engineer or Architec Firm (Pnnted) -7si- . Testing Laboratory Name (Printed) ~l~;!.::'''~N~~':") nspectiQorr~lStall;y~ame {Print I S ignatur1t2 ~~~Agen~ r ~ Huil IIlg fficial Signatl . SPECIAL INSPECTION AND TESTING SCHEDULE Reinforced Concrete, Gunite Grout and Mortar: Concrete Gunite Grout Mortar Al!l!re~ate Test of Mix Design Reinforcine. Test Mix Desip-n-Weiuhmaster Cert.. Reinforcine. Placement Continuous Batch Plant InsDcct. Insncct Placin; Cast Samnles Samn lesep ickun/Del ivered) Comoression Test* Precast/Pre-stressed Concrete: Piles Post-Tens Pre-Tens Claddin. A"oreoate Tests Reinforcinp" Tests Tendon Test Mix Desil7l1s* Reinforcinp Placement Insert Placement Concrete Batching ~. Concrete Placement Installation Insnection Cast Samoles Pick-un Samnles Comnressiol1 Tests SMOKE CONTROL:. FIREPROOFING: Leakage testing Control Verification Placement inspection Density tests Thickness tests Inspect batching ROOFING: Insulation installation/R-Value* Test strips/seams A'j!!;.IONAL INSRUCTIONS, OTHER TEST, & INSPECTIONS: :i- I NJ7l<n '- ,",7:> t,-7:>CH'V ,IT-Nt" /h I'p~ r GRADING, EXCA V A TION, AND FILL Acceptance tests '" PSF Establish final grade Fill placement inspection/continuous Soil Density STRUCTURALSTEELAVELDING: Sample and test (list specific menibers below) Shop material identification (mill cert) Weld inspection _Shop _Field Ultrasonic inspection _Shop _Field High Strength Bolting_Shop _Field A325 _N _X F A490 _N _X - F Metal deck welding inspection Reinforcing Steel welding inspection Reinforcing steel mill certificate Metal stud welding inspection Concrete insert welding inspection Moment resisting steel frames STRUCTURAL WOOD: Shear wall nailing inspection Shear wall anchors Inspection ofGlu-Jam fab. '" TIC psi Inspection oftl1Jss joist fab. Sample and test components Fabricat!on welding of steel accessories MASONRV Special inspection stresses used'" I'm t'g Preliminary acceptance tests (masonry units, wall prisms) v' / Subse:quent tests (mortar, grout, field wall prisms) Placement inspection oful1its, and reinforcement Masonry, mortar, grout, and reinforcing steel certificates Form Completed by: Cc-- Date ~/'I Ii) .PROVIDE STRENGTH REQUIRED BY ARCHITECT OR ENGINEER OR CONTRACT DOCUMENT LOCATION OF VALVES ,:"... ~ -\ Cr'