HomeMy WebLinkAboutCorrespondence PLANNER 6/22/2009
....
''I.,
.
HOPKINS Steve
From:
Sent:
To:
Subject:
CARPENTER Christopher
Monday, June 22, 2009 3:50 PM
HOPKINS Steve
DRC2009-00022 AND DRC2009-00023
/a.r}(.-~ /(1/
Hi Steve-
Regarding DRC2009-00022:
1) Oregon Revised Statute 447233 requires (2) two accessible parking spaces for parking lots with 26-50 spaces-
the proposed design identifies only one space.
2) The Oregon Structural Specialty Code section 1104.4.5 requires that these spaces be on the shortest accessible
route to accessible building(s) /entrance(s)- The provided narrative implies that the proposed van accessible
space is to serve the A3 and the Gateways High School: Unless the high school is served by another space not
identified on the plans, proximate to the H.S. building entrance(s), the location of the proposed space would not
comply even if there were two accessible spaces there.
3) The accessible route is required to have detectable warnings and a marked crossing (also per OSSC 1104.4.5)- no
marked crossing is identified on the proposed plans.
As the site is essentially flat, compliance with the slopes/grades required by accessibility standards should not be
difficult, and I see no other issues worth noting at this time.
Regarding DRC2009-00023:
No issues worth noting.
Best regards,
CHRIS CARPENTER
PLANS EXAMINER
SPRINGFIELD COMMUNITY SERVICES
225 FIFTH STREET
SPRINGFIELD, OREGON 97477
(541) 744.4153
(541) 726.3676 FAX
CCARPENTER@CI.SPRINGFIELD.OR.US
WWW.CI.sPRINGFIELD.OR.U5
~
SP~I~~. ~ "<.'~
~. . ~=r
'f' ~ . ThinkPermit
. .-, OR.EGON ~,..__I=tKI:.,..ldy.
( _ 12 .oj
. . 0
Date ReCElIVe(L
Planner: SH
1