Loading...
HomeMy WebLinkAboutPermit Building 1999-5-17 t' Page 1 RESIDENTIAL PERMIT APPLICATION CITY OF SPRINGFIELD COMMUNITY SERVICES DIVISION BUILDING SAFETY Job Number: 990561 225 North Fifth Street Springfield, OR 97477 Office: 726-3759 Inspection Line: 726-3769 Location of Proposed Work: 1227 W OLYMPIC ST Assessors Map #: 17032131 Lot: Block: Tax Lot #: 01304 Subdivision: Owner: RANDY SALTMARCH Address: 1227 W. OLYMPIC Phone #: 689-2917 City/State/Zip: SPLFD OR, Describe Work: SHOP/GARAGE NEW Contractor Const. Contractor # Expires Phone ALPINE CO~TrENI/n 0085928 87948 DQW~~ s~eld OR 974 :~vqltfical;n e~ adODlo ? laW rA ". "'V"IR _'11#-'""'__ a'~'r!1 '7-\...:s~ 009 9S2-aDt~7H eOrag OUto O. You 'lBmOll1iW,~a1lr% on Utillt Calling th:aJ:~~fl c rlfliga o~ Sat foith nUmbatfn.~;cantar {"OP~aSnf~."" 952-on1 To request an inspecti.on.cewrYl~~alu'f!i.~llll/tei&c~ at 726-3769. ar IS 1-800 tl/11y No/? O?a All inspections requested before 7:0~3g~f~t~ made the same inspections requested after 7:00 a.m. willrSe made t~~ following General: 10/27/99 686-5431 QUAD AREA: lRNW OCCY GROUP: U # OF BLDGS: 1 SQ FOOTAGE: 864 working day, work day. REQUIRED INSPECTIONS FOOTING - After trenches are excavated. SLAB - TO be made after all inslab building service equipment, conduit ~ piping, and other equipment items are in place but prior to concrete ROUGH ELECTRICAL - Prior to cover. SHEAR WALL NAILING - Before covering sheathing with .finish materials. FRAMING - Prior to cover. FINAL ELECTRICAL - When all electrical work is complete. FINAL BUILDING - When all required inspections have been approved and the building is complete. Total Height: 13 Item Main Garage Total Value BUILDING PERMIT --- Square Feet x $/square Feet 000000 864 18.34 = Value 0.00 15,846.00 15,846.00 Building Permit Fee Surcharge/Admin 116.50 9.33 TOTAL FEE (A) 125.83 --- MISCELLANEOUS PERMITS --- Surcharge/Admin CITY SDC 0.00 205.94 TOTAL MISCELLANEOUS PERMITS (E) 205.94 (Excluding Electrical) unless otherwise noted TOTAL AMOUNT DUE (A, B, C, D, and E combined) 331.77 " , -. Job Number: 990561 Page 2 --- BUILDING VALUE, PLAN CHECK AND BUILDING PERMIT --- This permit is granted on the express condition that the said construction shall, in all respects, conform to the Ordinance adopted by the City of Springfield, including the Development Code, regulating the construction and use of buildings, and may be suspended or revoked at any time upon violation of any provisions of said ordinances. Plan Check Fee: 75.73 Date Paid: 04/26/99 Received By: Plans Reviewed By: AL WARD Date: 05/15/99 Building Site Reviewed By: BOB BARNHART Receipt Number: 033652 --- ADDITIONAL COMMENTS A SEPERATE ELECTRICAL PERMIT IS REQUIRED By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Servi~ ivision, Building Safety. I further certify that only contractors/and em oyees who are in compliance with ORS 701.055 will be / ~' used o~~this pro' ct. ~ // / . / ... I further agre to ensur~that all ~red ~nspect~ons are requested at the pr~per time, hat ~~address i~~dable from the street, that the permit card is lo ted ~the front Ythe property, and the approved set of plans will re 0 e site a times during construction. ~ ~~-- <. ..---- j/749 ./ 7ignature -- Date -- - VALIDATION Date Paid: J3t/o ?'7 ~ /;7/1/ 3)J~ Receipt Number: Amount Received: Received By: ~ "\.' . 4 ," . JO_L OR JOB NO. cNOS(,/ ATTACHMENT A .. CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE WORKSHEET NAME OR COMPANY: SA L:r MA,z,c. u LOCATION: \~"2.., W.OL..'fMf"IC'-.. DEVELOPMENT TYPE: ?At.At:..~ BUILDING SIZE: LOT SIZt SQ. Ft. 1. STORM DRAINAGE IMPERVIOUS SQ. FT. 'iSlA- X $0.227 PER SQ. FT. $ /Cf&, /3 2. SANITARY SEWER-CITY NO. OF PFU'S (See Reverse Side) X $47.14 PER PFU $ 3. TRANSPORTATION NO OF UNITS X TRIP RATE X COST PER TRIP X X $475.32 $ X X $475.32 $ - 4. SANITARY SEWER-MWMC A. REIMBURSEMENT COST: NO. OF FEU'S X PER FEU $ , B. IMPROVEMENT COST: NO. OF FEU'S X PER FEU TOTAL-MWMC SDC $ , < $ > $ 10.00 $ $ 19(",.13 $ o1.~ I MWMC CREDIT IF APPLICABLE (SEE REVERSE) MWMC ADMINISTRATIVE FEE SUBTOTAL (ADD ITEMS 1.2.3 & 4) 5. ADMINISTRATIVE FEES: BASE CHARGE (SUBTOTAL ABOVE) X .05 Me'",= SDC Coordinator ATIACH'A.WPD Date: 'JJIQI~) 7 TOTAL SDC $2:/5 C;4 FIXTURE UNIT CALCUI..Q..TION TABLE: Number of New FiX.S X Unit Equivaleni = Fixture {.iiits.... (NOTE: For remodels, calculate o"'e NET additional fixturesl NUMBER OF UNIT FIXTURE FIXTURE TYPE NEW FIXTURES EQUIVALENT UNITS Bathtub.................................,..................:................ . Drinking Fountain......... .............. ........................ ...... Floor Drain.. ..... ........ ......... ........ ................. ... ...... ...... Interceptors For Grease/Oil/Solids/Etc................. Interceptors For Sand/Auto Wash/Etc.................. Laundry Tub/Clotheswasher..................,............,... Clotheswasher - 3 Or More..............;...................... Mobile Home Park Trap (1 Per Trailer).................. Receptor For Refrigerator/Water Station/Etc........ Receptor For Commercial Sink/Dishwasher/Etc.. Shower, Single Stall................................................. Shower. Gang.....,. .~.............,..............,.................... Sink: Bar, Commercial,' Residential Kitchen........................ Urinal, Stall/Wall.......... ............... .......... ............... ..... Wash Basin/Lavatory, Single...... .... ...........:............ . Toilet, Public Installation........................................ Toilet, Private.... ............ ............. ...................... .... Miscellaneous: 2 1 2 3 6 2 6 6 1 3 2 l/Head 2 2 1 6 4 TOTAL FIXTURE UNITS = CREDIT CALCULATION TABLE: Based on assessed villue. If improvements occurred after annexation date in table. calculate credits separates. ./ ~ II Year Rate per $1 ,000 T Year Rate per $1,000 Annexed Assessed Value Annexed Assessed Value 1979 or before $4.27 1989 $1.98. 1980 4.18 1990 1.55 1981 4.12 1991 1.15 1982 3.99 1992 0.96 1983 3.83 1993 0.83 1984 3.68 1994 0.67 1985 3.48 1995 0.52 1986 3.18 1996 0.38 1987 2.82 1997 0.21 1988 2.42 Credit for Parcel or Land Only If Applicable X $ = (Rate X Assessed Value) X $ = (Rate X Assessed Value) CREDIT TOTAL = $ Improvement (if after snnexation date) RUNOFF COEFFICIENTS FOR STORM DRAINAGE (For Estimating Purposes Only) ResidentiaL...... ............. ....... 0.4 Commerical......................... 0.9 IndustriaL........................... 05 GovernmentaL..................... 0.5 FIXUNIT.wPO IMPERVIOUS AREA = TOTAL LOT SIZE X RUNOFF COEFFICIENT -ADDRESS- 1227 W OLYMPIC ST ~UILDING DIVISION JOB# 9411i4 -LEGAL- LOT 3 BLOCK MARATHON 1703273101300 FINAL DESCR:HOUSE MOVE URBAN GROWTH BOUNDARY -OWNER- THOMPSON/SALTMARSH 343-0003 3739 KEELER EUGENE, OREGON 97401 -VALUE- 28680 940830 / 950331 -ENERGY- HEAT1- H20- RANGE- INSULATION PATH- -STATS- BLDG ZONE LDR STORIES FLOODPLAIN BEDRM OCC GRP R3 UNITS SQ FEET CONST TYPE VN -CONTRACTORS- GENL-OWNER CONTRACTOR PHONE-726-1854 PLMB-OWNER ELECT-OWNER MECH-OWNER DESGN- 1 2- 1 -INFO- REPAIR RESIDENTIAL 1111 QUAD AREA 5RNW SEQ-REQUIRED PERMITS----------------FEE--SURCHARGE--DATE--RECPT--CAT-------VALUE 001-061-RES PLAN CHECK 122.53 0.00 940817 14361 0 002-005-PLUMBING 50.00 2.50 940912 14682 510 0 003-003-TEMP ELECTRICAL 40.00 2.00 940912 14682 500 0 004-004-ELECTRICAL 40.00 2.00 940922 14818 500 0 005-002-BUILDING PERMIT 188.50 9.43 940922 14815 601 28,680 006-005-PLUMBING 75.00 3.75 940922 14815 510 0 007-013-SIDEWALK 25.00 0.00 940922 14815 613 0 008-012-CURBCUT 11.80 0.00 940922 14815 612 0 009-070-SDCjSTORM 339.42 0.00 940922 14815 0 010-071-SDC/SANITARY 778.68 0.00 940922 14815 0 011-072-SDC/TRANSP 440.55 0.00 940922 14815 0 012-055-REGIONAL SEWER 319.42 0.00 940922 14815 0 013-073-SDC/ADMIN 93.90 0.00 940922 14815 0 014-074-SDC/WILLAMALANE 400.00 0.00 940922 14815 0 015-010-HOUSE MOVING 122.40 0.00 940922 14813 925 0 SEQ-MINIMUM INSPECTIONS + REQUIREMENTS--------------------EXP DATE---ACT DATE- 001-040-TEMPORARY ELECTR 002-126-LINE TO SEPTIC PUMP AND FILL SEPTIC 003-069-HSE MOVE COMPLETE 004-002-FOOTING 005-003-FOUNDATION 006-026-SANITARY SEWER 007-027-STORM SEWER 008-024-WATER LINE 009-023-ROUGH PLUMBING 010-042-ROUGH ELECTRIC ADDITIONAL PERMIT REQUIRED $40 PD 011-044-ELECTRIC SERVICE 012-006-FRAMING 013-011-DRYWALL 014-090-DRIVEWAYjCURBCUT 015-091-SIDEWALK 016-029-FINAL PLUMBING 017-049-FINAL ELECTRICAL 018-019-FINAL BUILDING 941010 941031 941107 950314 941107 950106 941228 941228 950314 950203 950331 SEQ--INSPECTIONS---------COMMENTS----------------------------DATE---RSLT--INSP 001-026-SANITARY SEWER 002-002-FOOTING 003-003-FOUNDATION HOUSE 941010 NOTOK 28 941010 OK 38 941031 OK 38 004-026-SANITARY SEWER - . 941103 NR 28 005-020-UNDERGROUND PLUM 941107 WIR 28 006-024-WATER LINE 941107 OK , 28 007-026-SANITARY SEWER 941107 OK 28 008-042-ROUGH ELECTRIC 941110 10 61 009-044-ELECTRIC SERVICE ROUGH 42 941117 OK 62 010-091-SIDEWALK DEPTH, 941227 NOTOK 43 011-090-DRIVEWAY/CURBCUT 941228 OK 43 012-091-SIDEWALK 941228 OK 43 013-023-ROUGH PLUMBING 950106 OK 28 014-021-UNDERFLOOR PLUMB 950106 OK 28 015-029-FINAL PLUMBING 950203 NOTOK 28 016-049-FINAL ELECTRICAL INSP. 42 OK 950203 OK 50 017-019-FINAL BUILDING 950203 10 59 018-039-FINAL MECHANICAL INSP. 69 OK 950203 NOTOK 28 019-029-FINAL PLUMBING 950314 OK 38 020-027-STORM SEWER 950314 OK 38 021-039-FINAL MECHANICAL 950314 OK 38 022-019-FINAL BUILDING SUB. OFF STREET PARKING 950331 OK 38 023-006-FRAMING NO GARAGE BUILT 950331 10 38