HomeMy WebLinkAboutNotes, Work PLANNER 11/10/2009
" " City of Springfield
Development Services Department
225 Fifth Street
Springfield, OR 97477
SITE PLAN REVIEW
PRE-SUBMITTAL CHECKLIST
Project Name: Taco Bell
Project Proposal: Redevelop existing Taco Bell site, expand restaurant
Case Number: PRE2009-00030
Project Address: 1505 Mohawk
Assessors Map and Tax Lot Number(s): 17-03-25-34 TL4101
Zoning: MUC (Mixed Use Commercial)
Overlay District(s): Nodal Development (INDO)
Applicable Refinement Plan: N/A
Refinement Plan Designation: N/A
Metro Plan Designation: Major Retail Centers
Pre-Submittal Meeting Date: November 10, 2009
Application Submittal Deadline: May 9, 2010
Associated Applications: Drinking Water Protection Overlay
IllGll'iY'olfJ$eIUN'GfEIEI!D1UE~El!oeMEN1I"1iR.E~'IElMliIlE~M~~_lIIIilil._lIIIilill'III
I POSITION I REVIEW OF I NAME PHONE I
I Proiect Planner Land Use PlanninQ I Steve Hopkins 726-3649 I
I I Transportation I Richard Perry 726-3679 I
1 Utilities Clayton 1736-1036 I
Mcearchern
I Sanitarv & Storm Sewer I
I Deputy Fire Marshal Fire and Life Safety Gilbert Gordon 726-2293 I
I Communitv, SerVices ManaQer I BuildinQ I Dave Puent 726-3668 I
~epI!Ie~N1I"!#SiDE~El!oeMEI'!I1I".R.EXtiIEWii1iE~MP4!l"."lIIIilil.lItiiIiii~
Applicant Owner
Belleo enterporises,LLC Cuddeback Commercial Properties, Inc
Robin Sanders Tim Campbell
PO Box FF Campbell Commercial REs I Estate
Springfield OR 97477 859 Willamette St, Suite 520
EUQene OR 97401
Revised 10/25/07
TENTATIVE SITE PLAN REVIEW APPLICATION
PRE-SUBMITTAL CHECKLIST
PLANNING
o Application fee - discuss the applicable fees
o Copy of the Site Plan reduced to 8'h"x 11"
Complete Incomplete See Planning
. Note(s)
~
8 V2" X 11" Copy of Site Plan
o Copy of the deed and a preliminary title report issued within the past 30 days
documenting ownership and listing all encumbrances. If the applicant is not the property
owner, written permission from the property owner is required.
Complete Incomplete See Planning
Note(s)
-
~
Deed and Preliminary Title Report
o Brief narrative explaining the purpose of the development, the existing use of the
property, and any additional information that may have a bearing in determining the
action to be taken. The narrative should also include the proposed number of employees
and future expansion plans, if known.
Complete Incomplete See Planning
Note(s)
~
III
Brief Narrative
o Site Plan
Complete Incomplete See Planning
Note(s)
o
Ili:I
l!tl
1%'1
~
[II
1
Prepared by an Oregon Licensed Architect,
Landscape Architect, or Engineer
Proposed buildings: location, dimensions,
size (gross floor area applicable to the
parking requirement for the proposed
use(s)), setbacks from property lines, and
distance between buildings
Location and height of existing or proposed
fences, walls, outdoor equipment, storage,
trash receptacles, and signs
Location, dimensions, and number of typical,
compact, and disabled parking spaces;
including aisles, wheel bumpers, directional
signs, and striping
Dimensions of the development area, as well
as area and percentage of the site proposed
for buildings, structures, parking and
~
Ili:I
If.Zil
~
mI
~
mI
Revised 10/25/07
~ mI
"' fJJIi
~ mI
"'
~ [II 2
~ mI
"*ii
~
I]
vehicular areas, sidewalks, patios, and other
impervious surfaces
Observance of solar access requirements as
speCified in the applicable zoning district
On-site loading areas and vehicular and
pedestrian circulation
Location, type, and number of bicycle
parking spaces.
Area and dimensions of all property to be
conveyed, dedicated, or reserved for
common open spaces, recreational areas,
and other similar public and semi-public uses
Location of existing and proposed transit
facilities
o Phased Development Plan Where applicable, the Site Plan application must include a
phasing plan indicating any proposed phases for development, including the boundaries
and sequencing of each phase. Phasing must progress in a sequence promoting street
connectivity between the various phases of the development and accommodating other
required public improvements, including but not limited to, sanitary sewer, stormwater
management, water, and electricity. The applicant must indicate which phases apply to
the Site Plan application being submitted.
Complete Incomplete See Planning N/A
Note(s)
III
III
o Landscape Plan
Complete Incomplete See Planning
Note(s)
1%'1
~
~
r5I
.~
III
J'37I
lZZSI
~
~
~
~
1
~
~
III
o Architectural Plan
Complete Incomplete See Planning
Note(s)
~
Revised 10/25/07
Phased Development Plan
Drawn by a Landscape Architect
Location and dimensions of landscaping and
'open space areas to include calculation of
landscape coverage
Screening in accordance with SDC 4.4-110
Written description, including specifications, of
the permanent irrigation system
Location and type of street trees
List in chart form the proposed types of
lalJdscape materials (trees, shrubs, ground
cover). Include in the chart genus, species,
common name, quantity, size, spacing and
method of planting
Exterior elevations of all buildings and
J'37I
.~
F0'l
l5Et
structures proposed for the development site,
including height
Conceptual floor plans
o On-Site Lighting Plan
Complete Incomplete See Planning
Note(s)
3
~
IiiiI
t=
III
~
3
Location, orientation, and maximum height of
exterior light fixtures, both free standing and
attached
Type and extent of shielding, including cut-off
angles and type of illumination, wattage,and
luminous area
Photometric test report for each light source
~
!Un
~
3
Planning Notes:
1. Need diagram of trash enclosure and piping. Refer to #4.
2. diagram/description of long term bike spaces: covered & secure
3. No photometric report needed if: pole lighting is max 250W, wall packs are max
lOOW. Need cut sheets for wall packs.
4. The trash enclosure needs to be screened and hydraulically separated from storm
drain. Refer to SDC4.1-110 for screening options
5. Utility Plan: show the sanitary and storm lines. All utilities must be underground.
6. ROWand property lines are not clear
7. plans will need to be stamped
Additional comments not related to the completeness of the application:
base
$4,222.00
tech %
5%
tech $ I mail I
$211.10 $160.00
total I
$4,593.10 I
The site is within the 1-5 yearTime of Travel zone. A Drinking Water Protection Overlay
application is required or an exemption from SUB. Contact Amy Chinitz (744-3745) prior to
submitting the complete site plan application. If an exemption is not granted, a DWP
application can be processed concurrently with the site plan.
Revised 10/25/07
City of Springfield
Development Services Department
225 Fifth Street
Springfield, OR 97477
ANY REQUIRED ADDITIONAL MATERIALS, APPLICATIONS OR
PERMITS
IT IS THE APPLICANT'S RESPONSIBILITY TO DETERMINE IF ADDITIONAL STANDARDS OR
APPLICATIONS APPLY TO THE PROPOSED DEVELOPMENT. THE APPLICANT SHOULD
CONSIDER UTILIZING EITHER THE DEVELOPMENT ISSUES MEETING OR THE PRE-
APPLICATION REPORT FOR MORE DETAILED INFORMATION:
Applicable
Not
Applicable
1%'1.' .
~
o
Where a multi-family development is proposed, any additional
. materials to demonstrate compliance with SDC 3.2-240
Riparian Area Protection Report for properties located within 150
feet of the top of bank of any Water Quality Limited Watercourses
(WQLW) or within 100 feet of the top of bank of any direct
tributaries of WQLW
A Geotechnical Report prepared by an engineer must be submitted
concurrently if there are unstable soils and/or a high water table
present
Where the development area is within an overlay district, address
the additional standards of the overlay district
If five or more trees are proposed to be removed, a Tree Felling
Permit as specified in SDC 5.19-100
A wetland delineation approved by the Oregon Division of State
Lands must be submitted concurrently where there is a wetland on
the property
Any required federal or state permit must be submitted
concurrently or evidence the permit application has been
submitted for review
Where any grading, filling or excavating is proposed with the
development, a Land and Drainage Alteration permit must be
submitted prior to development
Where applicable, any Discretionary Use or Variance as specified in
SDC 5.9-100 and 5.21-100
An Annexation application, as specified in SDC 5.7-100, where a
development is proposed outside of the city limits but within the
City's urban service area and can be serviced by sanitary sewer
[II
mI
Ili:I
~
1%'1
lZ?:iJ
~
mI
mI
o
mI
~
1'0
. ~
~
fil
mI
~
[II
~
Revised 10/25/07
THIS APPLICATION IS:
o COMPLETE FOR PROCESSING
~ INCOMPLETE AND NEEDS MISSING INFORMATION NOTED ABOVE
c;~~ lfJ
/J J/ 0 IIY1
pate I
This is not a decision on your application. Springfield Development Code Section 5.4-
105 and Oregon Revised Statutes 227.178 require the City take final action on a limited land
use decision within 120 days after the application is deemed complete. The 120-day
processing period for this application begins when all the missing information is submitted or
, when you request that the City proceed without the information. You must indicate by either
signing this form or by submitting a written response to the City within seven days of the
date of this form asserting your intentions regarding the provision of the missing
information'. If you indicate herein or in your written response that the missing information
will be submitted, then you have 180 days from the date the application was submitted for
Pre-Submittal Review to provide the City with the missing information. If you refuse to
submit the missing information, then upon receipt of the full application packet and
processing fee, the City will deem the application complete for purposes of starting the 120-
day clock and begin processing the application. No new information may.pe submitted after
the start of the 120-day period unless accompanied by a request for an extension of the
120-day processing time. Upon receipt of a request for extension, the City may extend the
120-day period for a reasonable period of time. The City may also require additional fees if
the new information is submitted after the Notification to Surrounding Property Owners is
sent out and a second notification is required or if the new information substantially affects
the application proposal and additional review is required.
If the owner/applicant, intend to submit all missing items indicated herein to the
City wit. the ISO-day timeline."
cStAA~/
Own~I/Applicant's Signature
t~/ur
Revised 10/25/07
;.~
TENTATIVE SITE PLAN REVIEW APPLICATION
PRE-SUBMITTAL CHECKLIST
Engineer:
Case#: com2009-00030
PUBLIC WORKS ENGINEERING
Complete
o Site Assessment of Existing Conditions
IjI
1%'1
~
r;;;;;;l
~
r;;;;;;l
~
mI
~
~
mI
Revised 10/25/07
Incomplete
See PW
Note(s)
1
~
IjI
~
2
mI
n/a
Ili:I
l22:2J
n/a
[II
3
IjI
~
4
Prepared by an Oregon licensed Landscape Architect
or Engineer
Vicinity Map
The name, location, and dimensions of all existing site
features including buildings, curb cuts, trees and
impervious surface areas, clearly indicating what is
remaining and what is being removed. For existing
structures to remain, also indicate present use, size,
setbacks from property lines, and distance between
buildings
The name, location, dimensions, direction of flow and
top of bank of all watercourses and required riparian
setback that are shown on the Water Quality Limited
Watercourse Map on file in the Development Services
Department
The 100-year floodplain and f100dway boundaries on
the site, as specified in the latest adopted FEMA Flood
Insurance Rate Maps or FEMA approved Letter of Map
Amendmerit or Letter of Map Revision
The Time of Travel Zones, as specified in SDC 3.3-200
and delirieated on the Wellhead Protection Areas Map
on file in the Development Services Department
Physical features including, but not limited to trees 5"
in diameter or greater when measured 4 V2 feet above
the ground, significant clusters of trees and shrubs,
riparian areas, wetlands, and rock outcroppings
Soil types and water table information as mapped and
specified in the Soils Survey of Lane County. A
Geotechnical Report prepared by an Engineer must be
submitted concurrently if the Soils Survey indicates
the proposed development area has unstable soils
and/or a high water table
"' 0 Improvement and Public Utilities Plan must be in compliance with the regulations of
SDC Sections 5.17-100, 4.1"100, 4.2-100, and 4.3-100 and must include the following
information:
Complete Incomplete
~
"[j]
1li:I,
t=;j
liJ
1%'1
~
rv:'I
Il2SJ
See PW
Note(s)
1
5
~
n/a
~
6
Complete
o Grading and Paving Plan
mI
1li:I,
I.:J
Ili:I
~
~
~
~
~
Incomplete See PW
~ote(s)
~ 1
o 1
~ 7
~
lii1
t.=J
fii;;I
t!illlJ.
mI 8
Prepared by an Oregon licensed Civil, Engineer
Location and width of all existing and proposed
easements
Location of existing and required power poles,
transformers, neighborhood mailbox units, and similar
public facilities
Location and size of existing and proposed utilities on
and adjacent to the site, including sanitary sewer
mains, stormwater management systems, water
mains, power, gas, telephone, and cable TV.
Indicate the proposed connection points
Prepared by an Oregon licensed Civil Engineer
Planting plan prepared by an Oregon licensed
Landscape Architect where plants are proposed as
part of the stormwater management system
Roof drainage patterns and discharge locations .
Pervious and impervious area drainage patterns
The size and location of stormwater management
systems components, including but not limited to:
drain lines, catch basins, dry wells and/or detention
ponds; stormwater quality measures; and natural
drainageways to be retained
Existing and proposed spot elevations and contours
lines drawn at 1 foot intervals (for land with a slope
over 10 percent, the contour lines may be at 5 foot
intervals)
Amount of proposed cut and fill
o Stormwater Management System Study - provide four (4) copies of the study with
the completed Stormwater Scoping Sheet attached. The plan, calculations, and
documentation must be consistent with the Engineering Design Standards and
Procedures Manual.
Complete
~
Revised 10/25/07
Incomplete
See PW
Note(s)
9
III
Scoping Sheet and attached Stormwater Management
System Study
:;,
PW Notes:
1. landscape sheets not stamped by Landscape Architect. Engineers stamp not signed
with expiration.
2. ROW lines not clearly marked on Civil Plans
3. This development is in the 1-2 year Time Of Travel zone for Drinking water
protection. Amy Chinitz at SUB should be contacted for any special requirements
this Zone may require.
4. Soil type not shown. Due to nature of redevelopment of existing structure this is not
necessary. However a Pavement Section is required. City requirements for
emergency equipment access is that the pavement must support an 80,000 Ib
load (HS-20). The city standard to meet this requirement is 4 inches of AC over
12 in of base course. An alternative pavement design is acceptable with a
geotechnical engineers approval that it will satisfy the above requirement.
5. ROW for Mohawk Road not clearly shown.
6. Current and future sanitary sewer connection not shown. The trash enclosure will
require a hookup to sanitary sewer. Future water connection/meter location is
not shown
7. Roof downspout connections not shown. Roof mounted equipment will need to be,
sealed or roof runoff directed into bio swale before discharge into storm sewer
system.
8. Cut/Fill not shown. It does not appear that there will be significant earth work with
this development.
9.' Current storm drainage plans appear satisfactory except a higher percentage of
impervious area will need to be vegetatively treated. I can meet with the the
design engineer to discuss possible alternatives.
Additional comments not related to the completeness of the application:
. Due to the TOT zone, The bioswale will need to have 2' planting medium to ensure
adequate treament/filtration of stormwater runoff that infiltrates into the water
'table. '
. Due to known existing problems in this area the connections to sanitary and storm
sewer systems will need to field verified by city staff to be properly connected.
The city has discovered nearby developments with connection not made properly.
This is a known existing problem and no action will be taken except requiring
businesses to correct any unsatisfactory condition.
. treatment swale will need to have a wider bottom to adequately treat stormwater
runoff:
. Is any work planned in the Mohawk ROW? if so an encroachment permit with traffic
control will need to be obtained. City staff can assist with any necessary
requirements regarding this. '
.
.
Revised 10/25/07
TENTATIVE SITE PLAN REVIEW APPLICATION
PRE-SUBMITTAL CHECKLIST
Deputy Fire Marshal: Gilbert Gordon
Case #: PRE2009-00030
FIRE
,0 Site Plan
Complete Incomplete See Fire
Note(s)
~
IiJi1
L1ili:I
On-site vehicular circulation
o Improvement and Public Utilities Plal1
Complete Incomplete
r::::/1
t22SJ
F0'l
~
.see Fi re
Note(s)
'1.
Location of existing and required fire hydrants and
similar public facilities
Fire Notes:
1. Fire hydrant locations shown exceed allowable maximum distances per 2007
Springfield Fire Code 508.5. However, tlJll.!';.are}wo on-site public fire hydrants
located at the northwest corner of the o@:.Y'J(i'lt: ~~:I=:q and at the northeast
corner of Wendy's Restaurant (Springfield Utility Board fire hydrant numbers H-
271 and H-272 respectively). Show these fire hydrants on the site plan and
provide distances. If the distances to the farthest point away from the hydrant(s)
on the proposed building exceeds 400 feet, then either an additional fire hydrant
shall be installed or the building shall be sprinklered meeting NFPA 13
requirements. '-
Additional comments not related ,to the completeness of the application:
Fire apparatus access roads shall support an 80,000 lb. imposed load per 2007
Springfield Fire Code 503.2.3 and SFC Appendix D102.L
DK /0
U7! wl.,e~ ( ~
f71ftfw l-i ~"t"'C /-e> I.,. '0 I, ) /
r~ w'J tI/a,,~
- w'<.~ '1!J
- IV LV ((I1f! ~
Revised 9/24/07
TENTATIVE SITE PLAN REVIEW APPLICATION
PRE-SUBMITTAL CHECKLIST
Transportation Engineer/Planner: Richard Perry Case#: PRE2009-00030
Applicant: BELLCO ENTERPRISES
TRANSPORTATION
o Right-of-Way Approach Permit application must be provided where the property has
frontage on a Lane County or an Oregon Department of Transportation (ODOT) facility.
Complete Incomplete, See Transportation
Note(s)
J'37I
L::2::iJ
F0'l
~
Copy of ROW Approach Permit Application
o Traffic Impact Study - four (4) copies of a study prepared by a Traffic Engineer in
accordance with SDC 4.2-105 AA. Traffic Imp,act,Studi~~ (TIS) alloY' theCi,ty to analyze
and evaluate the traffic impacts and mitigation ofa:development on the City'S
transportation system. In general, a TIS must explain how the traffic'from a given
development affects the transportation system in terms of safety, traffic operations,
access and mobility, and immediate and adjoining street systems. A TIS must also
address, if needed, City, Metro Plan and state land use (lnd transportation policies and
objectives. . . ' --: ' " ,,:'
Complete Incomplete See Transportation
Note(s)
F0'l, ",
~
. ,", C
.' . \ .. l .... '-'.
Traffic'ImpaCt Study
,"
,-,,'.
IX7I
I.2!r:SJ
o Site Plan
... - '.". 'J' ~
.>> .' . ~ ." .
, "
~~~r:\U ~."I\
Complete Incomplete See Transportation
Note(s)
. "\;. ( . ~ ',',.
\
~
III
Access to streets, alleys, and properties to
be served, including the location and
dimensions of existing. and proposed curb
cuts and curb cuts proposed to be closed
o Improvement and Public Utilities Plan
Complete Incomplete
F0'l
~
~
See Transportation
Note(s)
1
Location and type of existing and
proposed street lighting
Location, width, and construction material
of all existing and proposed sidewalks,
sidewalk ramps, pedestrian access ways,
and trails
Location, widths (of paving and right-of-
way) and names of all existing and
proposed streets, alleys, dedications,
~
mI
III
~
2
Revised 10/25/07
~
III
access easements or other right-of-ways
within or adjacent to. the proposed
development, including ownership and
maintenance status, if applicable
Location of existing and required traffic
control devices
Transportation Notes:
1. Show existing street lighting in public right of way including type of light.
2. Expand extent of plan limits with respect to neighboring buildings and site
circulation. ' '
Additional comments not related to the completeness of the application:
.
\) P'j oil C),,,,
7 J,.-< '(;I- j,)h -I? ?
4\11 ~ tJM
1)1;' 6?
IJpt -Ir J;,r d, t[UtA t e.- dlll.(
h'l dftUJh - Vr..v tUr",.u
w~d1 ~
Revised 10/25/07
.~,
TENTATIVE SITE PLAN. REVIEW APPLICATION
PRE-SUBMITTAL CHECKLIST
Community services:~ Case '#: PR..B7-B81 ~[)f)e39-
o Site. Assessment of Existing Conditions cEfA'A!6-es- TO PR-DffatL-ry t-t::NE?
,Complete ; Incomplete .. See Building' .', CH-A}J~r ro' /rie ~A7-~ '
Note(s) .
Soil types and'~ater,tableinformation as 1JD
mapped and specified in the Soils Survey of
Lane County. A Geotechnical Report prepared
by an Engineer must b~ submitted'
concurrently if the Soils, ;3urvey indicates the
proposed development area has unstable soils
, and/or a high water table
[Ij]
r;:;m
I!!iJ
:p R-o Vtpff.
@ . 5lABft/lT-rT AL-
.0 SitePlan
Complete Incomplete See Building
Note(s)
[1].
~
$
oom
.m
f R-ov:n;:E
g 5Vtf:3f1r--r7frZ.-
fiiil
I.!ttJ
~
~
BUILDING
Proposed buildings: location, dimensions, size
(gross floor area), setbacks from property
. lines, distance between buildings
Location, dimensions, and number of typical,
compact, and disabled parking spaces;
including 'aisles, landscaped areas, wheel,'
bumpers, dire~tional signs, and striping
On-site loading areas and vehicular and
pedestrian circulation AcCPS5 [0
fUi?t;t:c c.Vt:'f
o Grading; Paving, and, Stormwater Management Plan
Incomplete' See Building
Note(s) ,
~ A-tJ 1 Cl-t-A~-'ES RO,of.drainage patterns and diSCh~rge locations
III ; . .J:xlstmgand proposed spot elevations and
TO E:f;fi-V/tr:J{/;)5 contours lines drawn at 1 foot intervals (for
{) F 1JtIt. Ir/V''I land with a slope over 10 percent, the contour
.' lines may be at 5 foot intervals)
~ ~NJFuMq;.! Amo~nt of proposed cut and fill
Complete
III
m
[IJ
o Architectural Plans P/LO\l':0)E.- <iY .51-rf'I'1I IT kL
Complete Incomplete See Building , '
Note(s)
!Un ~.'~.
I!!J I!!iJ
Revised 10/25/07 (\1e>ru:::vJ:.9:Vcl
ff;f-HF2.M~
~
. Exterior elevations of all building's and
structures proposed for the development site,
~:.. .
III
~
III
including height,
Conceptual floor plans
o On-Site Lighting Plan
Complete Incomplete
[\ill
. ~,~;.
~
See Planning
Note(s)
Egress Plan
Pf?-O~ ($. 51173./1..1- ( (A-z.-
Location, ori~ntation, and maximum height of
exterior light fixtures, both free standing and
attached
Typ'e arid e'xtent of shielding; including' CLJt-off
angles and type of illumination, wattage, and
luminous area
Photometric test report for each light source
ffi
~
~
Egress Plan
III
~
Egress Plan
'Po
140
Building Notes: ACC-J:;..5..5r:8~ J:;f?-rf\:n-5: C-OUA)-rf-42j
~1. . .5UF-S!3I<-ve / ,seA(T)6;' / RESTAx:fi15
r Additional comments not related to the completeness of the application:
o 1. Please provide complete civil, plan drawings including scale, dimensions,
setbacks to property lines, distances between structures, fire service lines, fire
hydrants,fire access, easements, utilities, parking,. accessible routes, etc...
o . 2. Please provide a complete set of plan documents wet-signature stamped by the
architects and engineers of record, including geo. tech. reports, building code
,analysis, fire and life safety plan review, accessibility, plumbing fixture analysis,
engineering for vertical and lateral loads with calculations and construction
. details, foundation plan, elevations, cross sections, floor plans, floor framing,
roof framing, etc... ,
o 3. Please provide automatic-sprinkler system plans, .fire and smoke alarm plans
including v,isible alarms, fire rated assemblies and 'opening protectives including
construction details and listings, etc.., .
o 4. Please provide electrical, plumbing and mechanical plan drawings including
engineering for seismic bracing, etc... '
o 5.' Please provide non-residential energy forms for exterior envelope, HVAC
systems, lighting systems, etc... .
o 6. Please provide documents for any special circumstances such as demolition, site
grading or waste water issues.
7. Please provide Sped;.1 Tn~n~ctinn Form signed by all responsible parties for any
, requiredspecial inspections. . .
8. Please provide.Deferred SIJbmittalJ'orm signed by all responsible parties for any,
deferred submittals.
1 L-DG A-R Eft :
5.F.
TIPe 0 FOJrJ)~t.{C:7p;7,tJ :
:7ff-J- tJ r~ + !rJ-M.fIJ :
Revised 10/25/07