Loading...
HomeMy WebLinkAboutBuilding Construction Specification 2003-2-11 . CertainTeed II Builders Statement . . InsulSafe~ 4 Fiber Glass Blowing Insulation r:,/T iJ tC!. "3 fI 0/''1 l' c; Homeowner Name I Jobsite Name s<' /I 0 (J. to /'~ kn " ~ Home Addre~ / 'It.:\ I~"r Installer/Contractor (s/gn) Builder (sign) Inspected By (sign if required) R-VAlUE . To obtain a Thermal Resistance (H) "I: 60 49 44 38 30 26 22 19 13 11 CEILINGS WAllS FLOORS '- d -..... I /) 1'1 " ~'-L rd" aTI 6 li\ l.(J Company Name Ff \, r<JM1 Date I). 'L005 r Company Name Date Date BAGS PER MAXIMUM MINIMUM WEIGHT- 1000 SQ. FT. SQ. FT. PER BAG POUNDS PER So. FT. Bags per Contents of bag Weight per sq. ft. of 1000 sq. ft should noteaver installed insulation should of net area: more than: (sq. ft.) not be less than: Obs.) 36,5 27 0.966 29.6 34 0.600 26.4 38 0.712 22.6 44 0.615 18.0 56 0.485 15.5 65 0.418 13.1 77 0.353 11.1 90 0.301 7.7 129 0.209 6.6 151 0.179 R-VALUE THICKNESS AREA (SQ. FT.) INSULSAFE .0" 1"1 'J'/1.. .,( ~-'1 V / 3t? j /I 0/4 J7&S V :ll (q fl'l 1"11)0 J..S- i? 1/6:) MINIMUM THICKNESS Should not be lessthan:1 (in.) 22 18lh 16Y-. 14Y. 12 10lh 9 7\\ 51> 4Y, BAGS USED BATTS/ROLlS (") ..:; LfO /v "rPtEe.. / V / V THERMAL PERFORMANCE-ArnC BLOWING APPLICATION In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. It. of net area for each R-Value listed. The maximum net coverage must not exceed that specified for each R-Value. The installed insulation must be at or above the specified minimum thickness for each R-Value. Failure to install the required minimum weight per sq. It. of insulation at or above the minimum thickness will result in reduced R-Value. This product should not be mixed with other blown insulations or the thermal claims will become invalid. . DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. 30-24-233 Builders Statement A Saint-Gobain Company C2002 CertainTeed Corporation 1/02 . Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@4 Fiber Glass Blowinglnsulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 1948:0, - CertainTeed II . '. . , THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW The following thermal performances are achieved at weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application: -, ' BAGS PER MAXIMUM' MINIMUM WEIGHT- MINIMUM R.VAlUE 1000 sQ. FT, SQ. FT. PER BAG POUNDS PER sQ. FT, THICKNESS To obtain a Bags per (ontentsofbag W~htPersq.ft.of Should not be Thermal Resistance 1000 sq. ft. should nalcover install insulation should less than: (R)of: or net area: morethan:(sq.ft.) not be less than: (1bs.1 (in.) 60 36.5 27 0.986 22 49 29.6 34 0.800 16111 44 26.4 38 0.712 16J/. 38 22.8 44 0.61S 14Jh 30 18.0. 56 0.48S 12 26 15.5 65 0.418 10111 22 13.1 77 0.353 9 19 11.1 90 0.301 711. 13 7.7 129 0.209 51/1 11 6.6 151 0.179 41f. . R-values are determined in accordance with ASTM C 687 and 518. Complies with ASTM C 764 as Type 1 insulation. THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION When installed with pneumatic equipment in sidewalls, the following thermal performances are achieved at the thicknesses, weights and coverages specified. BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM R.VALUE 1000 SQ. FT. sQ. FT. PER BAG POUNDS PER SQ. FT. THICKNESS To obtain a Bags per (ontenlS of bag W~ht per sq. ft. of Should not be Thermal Resistance 1000 sq. ft. should not cover install insuJalionshould less than: (Rlof: of net area; morethan;(sq.ft.l not be less than: (Ibs.1 (in.) 29 35.8 26 0.967 71/~ 22 27.2 37 0.733 51/2 16 19.B 51 0.533 4 15 17.9 56 0.483 3% 14 17.3 58 0.467 31/2 READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R- Value, the greater the insulating power. Compare insulation R-Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use . patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly.