Loading...
HomeMy WebLinkAboutPermit Backflow Test 1998-6-19 . 4-'" J . BACKFLOY PREVENTION DEVICE PERMIT APp~~~ik CITY OF SPRINGFIELD ~\~ \~~' BUILDING SAFETY DIV~'fi o':,f(-.~~ Of(-. \Cf(;. ~,,\..\.. 'f-\~ ~ ~~ ~ 225 FIFTH STREET ~O'\ ~~S 1i:i\ ~O~ OFFICE: 726-3759 SPRINGFIELD OR 97477 ~~~':,~ yJ)1J~<J \~"~~SPECTION LINE: 726-3769 __________________________________~~~-~~\P--~~~-~~~~---_______________________ JOB LOCATION: Spr..........{'eld c::::;'1~':,~'ti.t1fja1~ . ~ - e, ,vJJ" ~ .' ASSESSORS MAP #: /7(') 2.. ;2..J-Ll} ~~>( TAX LOT #: CJl-G 0 OYNER:-r;w, Wh/,'v-.. ADDRESS: 55 t.../ Oa.~rlal,,_ CITY:. C,N"..J,~/~ STATE: PHONE #: '1;q S ~S~ IS ZIP: 17911 or<. BACKFLOY PERMIT IS $15.00 + $.75 (STATE SURCHARGE) + $.45 (ADMIN. FEE) = $16.20 CONTRACTOR: (3<;W\.00 ADDRESS: ItJ20 ~<;t- .Ai PHONE #: CITY: S-:",r,'U?:p(r) STATE: OR- CONSTRUCTION CONTRACTORS REGISTRATION #: (;G crq 7C/(; -Gar ( ZIP: "77(./77 EXPIRES: BY SIGNING THIS PERMIT/APPLICATION, I AGREE TO CALL FOR AN INSPECTION ONCE THE BACKFLOY PREVENTION DEVICE HAS BEEN INSTALLED AND IS VISIBLE FOR INSPECTION (726-3769). I ALSO STATE THAT ALL INFORMATION ON THIS PERMIT/APPLICATION IS CORRECT. ~d. SlGNATUR~ J&jBlqr FOR OFFICE USE ::~:-::-:::::::~:::~--ll-r,-q-l-tf-~---------~-----------:::-:~-C?-~l)-()~-r 1.. " trn ~ RECEIPT It: ISSUED BY: J;/ [1 . ;) U TOTAL AMOUNT COLLECTED: L\ ~ I I , , I .. .. , . I . ... . ~ . POTABLE WATER SUPPLY ~ fI 1I~1 l0- (NOTES --.10 I 2 & 6 r OVERFLOW RIM \ '- AIR GAP r- --------------~---~~~~---~::~--:---~::--~~~;Ji) 1J' OVERFLOW \ -----------------------------------------------iwwy'r--; ~ PIPE ---..-' ===============================================: I - - - - - - - - - - - - - - - - - - - - - - - - ------------------------ - - - - - - --.:-:::-------------------------------- J ';::y--. ~ TO NON-POTABLE WA TER SYSTEM PUMP /,///////////////////////////////////////////////////////////////////////////'-'l. , REGIONAL DESIGN STANDARD EUGENE WATER II ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON I I FEB 01, 97 REV. WD6-6.2000 1 EWEB ENGINEERING REVIEW~'AL.~ "...- STANDARDS COMMITTEE APPROVAL ~ PAGE 1 OF 2 FEB 01, 97 REV. FF11DE42 0 SUB ENGINEERING REVIE~ AJRGAP BACKFLOW PROTECTION MINIMWIR GAPS FOR~W~T~~ DISTRIBUTION. When not affected FIXTURES by side walls' inches (MM) .. . '''. Lavatories and other fixtures with effective openings' not greater than one half (y,) inch (13 MM) in diameter. Sinks, laundry trays, goose neck bath faucets and other fixtures with effective openings' not greater than three quarters (0/.) inch (19 MM) in diameter. Over rim bath fillers and other fixtures with effective openings' not greater than one (1) inch (25 MM) in diameter. Effective openings' greater than one (1) inch (25 MM) in diameter. , , , When affected by side walls' inches (MM) 1" (25MM) 1 y," (38 MM) 1 y," (38 MM) 2X" (57 MM) 2" (51 MM) 3" (76 MM) Two (2) times diameter of effective openinq Three (3) times diameter of effective openinq , Side walls, ribs, or similar obstructions do not affect air gaps when spaced from the inside edge of ihe spout opening a distance greater than three times the diameter of the effective opening for a single wall, or a distance greater than four times the effective opening for two intersecting walls. , Vertical walls, ribs, or similar obstructions extending from the water surface to or above the horizontal plane of the spout opening otl1er than specified in note 1 above. The effect of three or more such vertical walls or ribs has not been determined. In such cases, the air gap shall be measured from the top of the wall. , The effective opening shall be the minimum cross-sectional area at the seat of the control valve or the supply pipe or tubing which feeds the device or outlet. If two or more lines supply one outlet, the effective opening shall be the sum of the cross-sectional areas of the individual supply lines or the area of the single outlet, whichever is smaller. . Air gaps less than one (1) inch (25 MM) shall be approved as a permanent part of a listed assembly that has been tested under actual backflow conditions with vacuums of from 0 to 25 inches of mercury, NOTES: 1, Air gap protection may be used in lieu of mechanical backflow protection, with EWEB or SUB approval in their respective service area. 2. All air gaps are measured from the bottom of the supply line to the top of the overflow rim of the sink or basin that is being filled. The air gap shall be twice the diameter (2xD) of the supply line, but in no case less than 1", If the supply line is adjacent to a wall, the air gap shall be increased to three times the diameter (3xD) of supply piping. 3. If the supply line is cut at an angle, the point closest to the basin is used for measurement. 4. If the supply line is reduced at the opening, the diameter used for air gap is taken at the largest portion of the supply piping. 5, There shall be no extensions or attachments on the open end of the supply piping. Any such extensions or attachments will void the air gap protection, 6. Reference document-Uniform Plumbing Code, Chapter 10, Section 1003, minimum air gaps for water distribution. REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARP. EUGENE. OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON FEB 01, 97 REV, AIRGAP BACKFLOW PROTECTION FEB 01, 97 REV. FF11 DE42 0 WD6-6.2000 1 PAGE 2 OF 2 ~ . . ~ (j NOTE 1 \ I~ .__ n__n~ n__ -__n_n_n_hnn --n__n_nhn_nhnh_ _'1' 11\ I I II ,GROUND ~J Jy. y. 11\ J"' ~ 11y' \ LINE ~ ; I ;,J V - i'l _ V J ~-r- ~r , I ~ 'L" [j 1'1 , / REGIONAL DESIGN STANDARD I EUGENE WATER & ELFC"R (' a'-"',RD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON I 11.1111. .- FES 01, 97 REV. WD6-6.3000 1 EWEB ENGINEERING REVIEW ~ /10.. I. .- STANDARDS COMMITTEE APPROVAL' fl!nY -.---'. PAGE 1 OF2 FEB 01. 97 REV. FF11DE43 0 SUB ENGINEERING REVIE~ ATMOSPHERIC VACUUM BREAKER - NOTES:. .. . 1. Atmospheric vacuum b. r shall be installed a minimum of 6" ab e highest piping or o~t1et that'it serves. 2. For testing and maintenance purposes, Atmospheric vacuum breaker (AVB) shall not be installed more than 5' above the ground or floor level, unless accompanied by a permanent OSHA approved platform. 3. All cleara'1ces apply to outside or in-building installations. 4. AVB's shall not be installed in an area where flooding is a possibility. 5. AVB's shall not be installed where dusty, corrosive, or toxic atmospheres are present. No chemical or fertilizer may be introduced through an irrigation system equipped with AVB's. 6. There shall be no shutoff valves downstream (on the discharge side) of the device. 7. Device cannot be under constant pressure more than 12 ho.urs in any 24 hour period. ITEM 1 = Approved AtmospheriC vacuum breaker (Devices with IAPMO and ASSE approval are approved by OHD) REGIONAL DESIGN STANDARD , EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON FEB 01.97 REV. WD6-6.3000 1 ATMOSPHERIC VACUUM BREAKER FEe 01, 97 FF11 DE43 REV. o PAGE Z OF 2 . . \ NOTE 1 ":- z . ~~ 1 : ~ ;0 NOiE 1 \ -, , ------------------------------------------------- --i ,11 I, II \ ~I~~U~D 'Z II!; I" l \1 1 Jl J 1 11:' ::E! J r. ' :~~_. V V -~/ V -= 1 ff IT Tr~ -;; ----- ,~~ I ~ I ,~, _,J) FEe 01, 97 PRESSURE VACUUM BREAKER ASSEMBLY o WD6-6.4000 1 EWEB ENGINEERING REVIEW M46' STANDARDS COMMITTEE APP~ ~ ,.- PAGE 1 OF 2 SUB ENGINEERING REVIEW@ .' NOTES: 1, Pressure vacuum breaker asserrAPVB) shall be installed a minimum of 12awe the highest piping, that it serves, 12" clearance abov~~ device for maintenance and 6" c1earan_ the tBst-cock side for testing, 2. For testing and maintenance purposes, PVB assembly shall not be installed more than 5' above ground or floor level, unless accompanied by a permanent OSHA approved platform. 3, All clearances apply to outside or in-building installations, When installed inside a building, there must be a drainage system capable of handling the volume of water which could discharge from the assembly. 4. PVS assembly shall not be installed in an area where it is possible to flood the assembly, 5, PV8's shall not be installed where dusty, corrosive, or toxic atmospheres are present. No chemical or fertilizer may be introduced through an irrigation system equipp~~ with PVS's. ITEM 1 = Approved pressure vacuum breaker assembly REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE. OREGON SPRINGFIELD UTILITY BOARO - SPRINGFIELD, OREGON , FEB 01, 97 REV, WD6-6.4000 1 . PRESSURE VACUUM BREAKER ASSEMBLY FES 01, 97 FF11DE44 REV. o PAGE20F2 < . ~ 4 " ~ -, j . . h ~ 4 4." . < ." "J/ PLAN h /" NOTE 7 ~. r / .f <%%~"{ ~o/,0" . ~. 0->>->'J/~ 3" . ::<<<<<<" --- ~").'/ I MIN ' ,0 [lJ~ ..c- ~ / NOTE 6 , Z '" - ::; 4 rNOTE 5 :~~ ELEVA TION REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON I FEe 01, 97 REV. WD6-6.51 001 DOUBLE CHECK VALVE ASSEMBLY, FEB 01, 97 REV. 1/2-2", BELOW GROUND FF11DE45 0 EWES ENGINEERING REVIEW ~""...1 .... STANDARDS COMMITTEE APPRaVA'C / ~ ., SUB ENGINEERING REVIEW e PAGE 1 OF 2 NOTES:. . 1, DoublB check valve asse shall be installed in a location approved ewEB or SUB for their' respective service arBa. 2, Double check valve assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4" or smaller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3, All clearances apply to outside, in-building, and vertical installations. 4. Insulation _ freeze protection to be insulation and/or heat source to keep enclosure at a minimum temperature of 40. F (NFPA 13-4-5,4.1.1). 5. Bore-sighted drain to daylight is required in all Springfield installations. Alternate methods may be approved by EWEB for devices in its service area. Allowable alternatives to daylight may include: A) dry well 6, Compacted gravel or undisturbed base. 7, A door or other access shall be provided. 8, Assemblies installed below ground level shall have watertight plugs or caps installed on the test cocks. FOR FIRE SERVICES: 9, Fire service assemblies shall be installed within 100' of EWEB's or SUB's point of service. 10. All piping preceding the double check valve shall be constructed of potable approved material, (E.G., PVC; lined cast iron, or ductile iron), 11. No outlets or connections 0ncluding hydrants) will be permitted on fire service lines prior to the couble check valve. ITEM 1 = Approved double check valve assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD, OREGON . FEB01.97 REV. DOUBLE CHECK VALVE ASSEMBLY, 1/2-2", BELOW GROUND FEe 01, 97 FF11 DE45 REV. o WD6-6.51 001 PAGE 2 OF 2 . . - J" -- MIN , Z <0 ~ L- 2~~~~~ ~~~J (') (~" \; U/ / ~ ( ) --. -----... , .\ __< _____\.1 ~ ~ ,r NOTE 4 a]OOOOO\ . Z <0 ~ :== ~NOTE 5 PLAN / ;3(jlSlilJl50 -u- 25 ~ / /, \' g l ",:~~ I I' ()QII ~. t z'x :E ~ lo U, , I V ::: ~"" , ~%%%%%~ ~%%%%%%%~%~~~~%~'%~~~ ~~%%%~ ~}:)..>>)::;..' .//%'::)..)~;..~/jY':-':." v.' \ ,~, _,' \ ,<,''''<{0~,''~~~ . h" I / /\~',(,:,,/..(..//' \... NOTE 6 \ "- ......./"'., REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE OREGON SPRINGFIEl flllTII.ITY !'OARD. SPRINGFIELD, OREGON II I II I' _I . FEe 01, 97 REV. DOUBLE CHECK VALVE ASSEMBLY, 1/2-2", ABOVE GROUND FEB 01. 97 REV. FF11DE46 0 WD6-6.5200 1 EWEB ENGINEERING REVIEW ~ STANDARDS COMMITTEE APPROVAL~ '" SUB ENGINEERING REVIEW ~ PAGE 1 OF 2 NOTES:. .' 1. DoublB check valve as Iy shall be installed in a location approv EWEB or SUB for their respective service area, 2. Double check valve assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4" or smaller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3. All clearances apply to outside, in-building, and vertical installations. 4. Insulation - freeze protection to be insulation and/or heat source to keep enclosure at a minimum temperature of 40. (NFPA 13-4-5.4,1.1.). 5. Bore-sighted drain to daylight is required in all Springfield installations. Alternate methods may be approved by EWEB for devices in its service area. Allowable alternatives to daylight may include: A) dry well 6. Compacted gravel or undisturbed base. 7. A door or other access shall be provided. FOR FIRE SERVICES: 9. Fire service assemblies shall be installed within 100' of EWEB's or SUB's point of service. 10. All piping preceding the double check valve shall be constructed of potable approved material, (E.G., PVC, lined cast iron, or ductile iron). _ 11. No outle~ or connections Oncluding hydrants) will be permitted on fire service lines prior to the double check valve. ITEM 1 = Approved double check valve assembly including factory supplied shutoff valves. \~ " ~ ,~~ ~') .Q ~\t\ ~",\. ",""'~~\ '., ..,,,,,a ""~.\~ REGIONAL DESIGN STANDARD I I EUGENE WATER & ELECTRIC BOARD. EUGENE OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD, OREGON FEB 01, 97 REV. DOUBLE CHECK VALVE ASSEMBLY, FEB 01, 97 REV. WD6-6.5200 1 1/2-2", ABOVE GROUND FF11DE46 0 PAGE20F2 J . r f"Ult Ii r NOTE 7 . / 4 / " ., " ------~- , , , I I I ^"CO z " I '" I .. I N " I / NOTE 10 I h - ~ , z :=J N _ I \ - ::; ~ ., --] '-NOTE 5 " .,. <1 ^ . PLAN .r NOTE 11 "-11'-ll'_II'_III_III_Ll R ~IIEIIEIIr=!II=:I' '=:111- i=.1 I CII Ell I.' ~,o 'IUIUld "-:Ii i=11.!1 e,f]"O ., I, (Ju(Jl't // / CO ,0, ! I NOTE 4 J ~ _1~~C~N_:B A END ," 1 A" ~~ - i"ill rro\:~IO~1 J ~l l \~ J~ J It ~~--! T " /4 NOTE 8 ~ /NOTE 7 I I ~ Il'..d.',..llI II 1.-1 I I-Ii I III 111 II. H,_",_ .III=:, , ,-, , ,-='II=:"I=:: 1 '=:11'=:"1 !IF-!lF-1l.F,' " . :11 1=1 Il=:l II=- CilCl11=- - :111=". , iz '..,;~ NOTE 12 ~ ..::...,INOTE 10 ~ q '-NOTE 5 -:111-1I1-III'm~r -'1'=111=:1,-'. .'-. NOTE 6 ELEVA TION ,: , REGIONAL DESIGN STANDARD EUGENE WATF,~ S E ECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON III. .. FEe 01, 97 REV. WD6-6.5400 1 EWEB ENGINEERING REVIEW ~ ~ STANDARDS COMMITTEE APPROVAL ~ DOUBLE CHECK VALVE ASSEMBLY, 21/2-10", BELOW GROUND PAGE 1 OF 2 FEB 01, 97 REV. FF11DE47 0 SUB ENGINEERING REVlEW@ . NOTES: 1, Double check valve assemblY. be installed in a location approved by Eva or SUB for their respective service area, · 2. Double check valve assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4" or ~maller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3. All clearances apply to outside, in-building, and vertical installations. 4, Insulation _ freeze protection to be insulation and/or heat source to keep enclosure at a minimum temperature of 400F (NFPA 13-4-5,4.1.1). 5, Bore-sighted drain to daylight is required in all Springfield installations. Alternate methods may be approved by EWEB for devices in its service area. Allowable alternatives may include: A) dry well (2 cubic yard minimum) B) sump pump 6, Compacted gravel or undisturbed base. 7. Hatch, minimum 3' x 3', spring assisted, galvanized or aluminum diamond plate, 8, All assemblies 2112" and larger shall have flange supports. 9, Assemblies installed below ground level shall have watertight plugs or caps installed on the lest cocks. 10, Watertight grout shall be used to seal openings, 11. If vault depth exceeds 4', use OSHA approved ladder (OAR Chapter 437, DMsion 2,1910.27). 12, Reinforced concrete vault (ASTM C-875). FOR FIRE SERVICES~ 13, Fire service assemblies shall be installed within 100' of EWEB's or SUB's point of service. 14, All piping preceding the double check valve shall be constructed of potable approved material (E.G., PVC, lined cast iron, or ductile iron). 15, No outlets or connections Oncluding hydrants) will be permitted on fire service lines prior to the double check. ITEM 1 = Approved double check valve assembly including factory suppli"ed shutoff valves. . 1 REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON FEB 01. 97 REV. DOUBLE CHECK VALVE ASSEMBLY, 21/2-10", BELOW GROUND FEe 01, 97 FF11DE47 REV. o 1 WD6-6.5400 1 PAGE20F2 NOTE 11 . ~ " ,,' " z ~ , " '" " JNOTE 10 h q . Z N _ - " " " ^ . \ "-- NOTE 5 " '"' " PLAN ~m.:..!..lm" 'm" 'fTi~mll'm~ '=IIUIUII: " '1r=!IUIU , '-:J 11-:111; M ~JU IJlSli( .....S / :::J NOTE 4 / :::J / NOTE 7 I I ~m~m'l 'm~m~iTi:=m~m~f""r.lm~aT~. " :IIUI=Ir==' C111=iTF :111='" . 1= ",1- ,::; r NOTE '1 ".d J oJ! ~ , ~ 12'M1Ni,n ~ n 't,,' Inr. ~~~u , H 1t .. -- ~ l[ NO TE 12 h " jNOTE 10 -, ~ I r- " / <l NOTE 8 ~ \ "-- NOTE 5 ~rr1=m m:=m" r -"1=111=111-'. -~ NOTE 6 ELEVA TIOf\1 , , REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD _ SPRINGFIELD, OREGON APR 25, 97 REV. WD6-6.5430 0 DOUBLE CHECK VALVE ASSEMBLY, 21/2-10", BELOW GROUND AMES SS/SE PATTERN APR 25. 97 REV. FF11DE55 0 EWEB ENGINEERING REVIEW -emc Au.L ___ STANDARDS COMMITTEE APPROVAL ~ PAGE 1 OF 2 SUB ENGINEERING REVIEW @ NOTES: . 1. Double ,check ~alve asSemblY. be installed in a location approved by Ee or SUB for their respective service area, 2. Double check valve assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4" or smaller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3, All clearances apply to outside, in-building, and vertical installations. 4, Insulation _ freeze protection to be insulation and/or heat source to keep enclosure at a minimum temperature of 40'F (NFPA 13-4-S.4,l.1), S, Bore-sighted drain to daylight is required in all Springfield installations. Alternate methods may be approved by EW~B for devices in its service area. Allowable alternatives may include: A) dry well (2 cubic yard minimum) B) sump pump 6, Compacted gravel or undisturbed base. 7, Hatch, minimum 3' x 3', spring assisted, galvanized or aluminum diamond plate. 8, All assemblies 2112" and larger shall have flange supports. 9. Assemblies installed below ground level shall have watertight plugs or caps installed on the test cocks. 10. Watertight grout shall be used to seal openings. 11. If vault depth exceeds 4', use OSHA approved ladder (OAR Chapter 437, Division 2,1910.27). 12. Reinforced concrete vault (ASTM C-87S). FOR FIRE SERVICES: 13, Fire service assemblies shall be installed within 100' of EWEB's or SUB's point of service. 14. All piping preceding the double check valve shall be constructed of potable approved material (E.G., PVC, lined cast iron, or ductile iron), lS. No outlets or connec~ons (including hydrants) will be permitted on fire service lines prior to the double check, ITEM 1 = Approved double check valve assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD, OREGON APR 25. 97 REV. DOUBLE CHECK VALVE ASSEMBLY, 21/2-10", BELOW GROUND AMES SS/SE PATTERN APR 25, 97 REV. FF11 CE55 0 WD6-6.5430 0 PAGE 2 OF 2 . ~.,;. rNOTE 5 ....:ii_.:.~ ,-NOiE 7 I- ~~ IFiTc:'ITi=Tii=iii~m=D1=ij~iTi3TETn? I . . . .. 3IEIIElIE=' , '. l=JII~IF . '= ,. 311=" _ ."'t'" --r; NOTE 9 .. ..:f:-- r0) _ '. -NOTE 12 In", / ~- 'li[~CO ~I i I'~. ~ 11>= ,J) ~ m' 'kt,F r:---... ~ r--; ;..L1 rr~) ~ i!J, ~ \~q ~ d=_ IT ~... n , . , , '.' p . I h I '.~ NOT[ 7-'/' I . I .4 17" I I ________~ z :; , IT .. . N , ';"Tz . ~, - ," , , . . , r .. NOTE 11.J PLAN rNQTE 11 ~ill~iTEjTI~['i~)T<'!,!T1i: '. ~O ~IElI1311: .. . II 1,=1113113.. . -o'~I~ /~tltlllffij~ /.i2 10 NOTE 4..../ . " , LC P II ~l. , . . t-I ;; - :; '. ;. / / NOTE a _/ .' '0 _ -:;1 ~111=lli=m~i' NOIt. 0 ~=1l1=-'1I . ELEv,,^, TION =~ .:- '\.. NOTE 10 yNOTE 10. ~ . 4 '::j~ NOTE 5 REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD - EUGENE, OREGON SPRINGFIELD UTILITY BOARO. SPRINGFIELD, OREGON I Apr 25, 97 REV. WD6-6.5440 0 DOUBLE CHECK VALVE ASSEMBLY, 2 1/2- APR 25. 97 10", BELOW GROUND FF11DE56 FEBCO N PATTERN REV. o EWEB ENGINEERING REVIEW ~ STANDARDS COMMITTEE APPROVAL ~ PAGE 1 OF 2 SUB ENGINEERING REVlEWe.. NOTES: 1. Double check valve assem.all be installed in a location approved by.B or SUB for thei; respective service area, 2. Double check valve assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4" cr smaller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3. All clearances apply to outside, in-building, and vertical installations. 4, Insulation - freeze protection to be insulation and/or heat source to keep enclosure at a minimum temperature of 400F (NFPA 13-4-5.4,1,1). . 5. Bore-sighted drain to daylight is required in all Springfield installations, Alternate methods may be approved by EWEB for devices in its service area, Allowable alternatives may include: A) dry well (2 cubic yard minimum) B) sump pump 6. Compacted gravel or undisturbed base. 7. Hatch, minimum 3' x 3', spring assisted, galvanized or aluminum diamond plate, 8, All assemblies 2 1/2" and larger shall have flange supports. 9. Assemblies installed below ground level shall have watertight plugs or caps installed on the test cocks. 10. Watertight grout shall be used to seal openings. 11, If vault depth exceeds 4', use OSHA approved ladder (OAR Chapter 437, Division 2, 1910.27). 12. Reinforced concrete vault (ASTM C-875). FOR FIRE SERVICES: 13, Fire service assemblies shall be installed within 100' of EWEB's or SUB's point of service. 14. All piping preceding the double check valve shall be constructed of potable approved material (E.G., PVC, lined cast iron, or ductile iron). 15, No outlets or connections Dncluding hydrants) will be permitted on fire service lines prior to the double check. ' ITEM 1 = Approved double check valve assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD I EUGENE WATER & ELECTRIC BOARD. EUGENE OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD. OREGON' APR 25, 97 REV. DOUBLE CHECK VALVE ASSEMBLY, 21/2-10", BEL,OW GROUND FEBCO N PATTERN APR 25, 97 FF11DE56 REV. o WD 6-6.5440 0 PAGE20F2 . (NOTE 7 !,OTE 4 .:~'1--{"" , '" e::- -. )= = ==3 PLAN if II IUJ-' I II i / II II T UJJllU I II i I I i\ / NOTE 9 _ II) IJ itll /.1 ilLUUI.IIIUl11IJ un /.I I 111/IIILiIIIIlIIIIIIIIIIIl II II i [I j /.I i 111 II i III II i I (/ I i I I I I /I l 'I't " "'j " . f II 11, f'l " 'I II Z/ ,m-." ,g ,~ "-- NOTE 4 ~ @ --...::'1 i'5 J 1 1f o:O!~t I ~~j"'~ 1J ~m3lFTiu.,; I 'SII:=:JIEIjj! ';;"'=il'~ \ \. NOTE 6 \, \..Nor::: 8 'I, r NOTe: 5 , ELEVA TION l'II:3Ti3Ti~~ ~ =;/1311::'311= -";-1"_' ~ REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON I II FEe 01, 97 REV. WD6-6.5500 1 DOUBLE CHECK VALVE ASSEMBLY, 21/2-10", ABOVE GROUND FEB 01, 97 REV. FF11DE48 0 EWEB ENGINEERING REVIEW I'!I'\~ STANDARDS COMMITTEE APPRavAt'~ PAGE 1 OF2 SUB ENGINEERING REVIEW ~ .. NOTES: 1. Do~ble check valve assemblY. be installed in a location approved by E~ or SUB for their respective selVlce area. · 2. Double check valve assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4" or smaller C) is recommended by the manufacturer for vertical installations 0) has the normal flow upward 3. All clearances apply to outside, in-building, and vertical installations. 4, Insulation _ freeze protection to be insulation and/or heat source to keep enclosure at a minimum temperature of 400F (NFPA 13-4-5.4.1.1), 5. Bore-sighted drain to daylight. 6, Compacted gravel or undisturbed base, 7, A door or other access shall be provided. 8, All assemblies 2 112" and larger shall have flange supports. 9. All structures to comply with local codes. FOR FIRE SERVICES:. 10. Fire service assemblies shall be installed within 100' of EWEB's or SUB's point of service. 11. All piping preceding the double check valve shall be constructed of potable approved material, (E.G., PVC, lined cast iron, or ductile iron), 12. No outlets or connections 0ncluding hydrants) will be permitted on fire service lines prior to the double check valve. ITEM 1 = Approved double check valve assembly including factory supplied shutoff valves REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD _ EUGENE. OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD. OREGON REV. o ] ~ FEB 01.97 REV. DOUBLE CHECK VALVE ASSEMBLY, 21/2-10", ABOVE GROUND WD6-6.5500 1 PAGE 2 OF 2 I FEB 01,97 FF11DE48 . / "V'L . . f NOTE 4 , I ~ 1 'nunnu'_L"" , '" N c:c ~'f!~: ~ ~ - :;; )====2 PLAN .. -rr 1/ ITlT I I n TI-OJI n I urTTl1 I I II II UJ1JI II II II. II /.1 1111 II II. I I II ill) 1111. I) II /111 /1 ///1 _ 1/ [II/II IJ IULII 1111 II illl II/III 111/. I) I 1: 1111 I, I II 11 r II I' ! I , I I II ., ! 111 II I I II /, "'- ,~OTE 4 ------ ~ " i=5 L "",~I t EACH I _ ~ I END cl~'.'o cl ' .. r;=Jqjjvr~ll_1 . > r J[ JL~~ t~ / NOTE 9 , z "'- '" "~iTi311~iTi""' '-::IIClldill '~rl=JII=1/ r NOTE 5 , \ ~NOTE e '- NOTE 6 ELEV,.!l,TION I . ~ rl8li~m3TE =IICIIUIC' -'I:--tll_' ~ REGIONAL DESIGN STANDARD EUGENl; WATER & ELECTRIC BOARD. EUGENF '~REGON SPRINCFIELD UTILITY BOARD. SPRINGFIELD, OREGON . I II . . . APR 25, 97 REV. WD6-6.5530 0 DOUBLE CHECK VALVE ASSEMBLY, APR 25. 97 REV. 21/2-10", ABOVE GROUND FF11 DE57 0 AMES SS/SE PATTERN EWES ENGINEERING REVIEW ~ STANDARDS COMMITTEE APPROVAL:::1!#r' . I- PAGE 1 OF 2 S~B ENGINEERING REVIEW yp NOTES: 1. Double check ~alve assembly.1 be installed in a location approved by EW or SUB for their respective seMce area. · 2, Double check valve assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4" or smaller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3. All clearances apply to outside, in-building, and vertical installations. 4, Insulation _ freeze protection to be insulation and/or heat source to keep enclosure at a minimum temperature of 400F (NFPA 13-4-5.4.1.1). 5. Bore-sighted drain to daylight. 6. Compacted gravel or undisturbed base, 7. A door or other access shall be provided. 8. All assemblies 21/2" and larger shall have flange supports. 9. All structures to comply with local codes. FOR FIRE SERV1CE~ 10. Fire service assemblies shall be installed within 100' of EWEB's or SUB's point of service. 11. All piping preceding the double check valve shall be constructed of potable approved material, (E.G., PVC, lined cast iron, or ductile iron), 12, No outlets or connections ~ncluding hydrants) will be permitted on fire service lines prior to the double check valve, ITEM 1 = Approved double check valve assembly including factory supplied shutoff valves I I REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD, OREGON APR 25. 97 REV, DOUBLE CHECK VALVE ASSEMBLY, 21/2-10", ABOVE GROUND AMES SS/SE PATTERN WD6-6.5530 0 PAGE20F2 APR 25, 97 FF11DE57 REV. o i . __ NOTE 7 -=-- s== ~:( , Z N - - " )= = = = ~ z :; . ~ \ . . . \l\l\7\l\l~ '- NOTE 5 , ."'-- NOTE 4 ~ v N PLAN / NOTE 9 , , ~ . , ,\ I 1 I ~~IiJ1~ -" " I r NOTE 5 --1, ~l ijj':3TEiTEiTi~ =J11311311:? ""I~II-' ~ ~.I~iTi':3ITITD" I -=111311311) ,-,tl=:jtl,",,?, p \ \.. NOTE 6 " ~NOTE 8 ELEVATION REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD - EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD. OREGON APR 25, 97 REV. WD6-6.5540 0 DOUBLE CHECK VALVE ASSEMBLY, 21/2-10", ABOVE GROUND FEBCO N PATTERN APR 25, 97 REV. FF11 DE58 0 EWEB ENGINEERING REVIEW ~W STANDARDS COMMITTEE APPROVAL ~ SUB ENGINEERING REVIEW @ PAGE 1 OF 2 ~: . . 1. Double check valve assBm.all be installed in a location approved by B or SUB for thBir respective service area, . 2. Double check valve assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4" or smaller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3. All clearances apply to outside, in-building, and vertical installations, 4. Insulation - freeze protection to be insulation and/or heat source to keep enclosure at a minimum temperature of 400F (NFPA 13-4-5,4.1.1). 5, Bore-sighted drain to daylight. 6, Compacted gravel or undisturbed base. 7, A door or other access shall be provided. a, All assemblies 2112" and larger shall have flange supports. 9. All structures to comply with local codes. FOR FIRE SERVICES: 10. Fire service assemblies shall be installed within 100' of EWES's or SUB's point of service. 11. All piping preceding the double check valve shall be constructed of potable approved material, (E.G., PVC, lined cast iron, or ductile iron), 12. No outlets or connections 0ncluding hydrants) will be permitted on fire $.ervice lines prior to the double check valve, ITEM 1 = Approved double check valve assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIEl!1 In' P' a()~RD. SP ~INGF1ElD, OREGON I_ 111_'1 I . I II I APR 25. 97 REV, WD6-6.5540 0 DOUBLE CHECK VALVE ASSEMBLY, 21/2-10", ABOVE GROUND FEBCO N PATTERN APR 25, 97 REV. FF11DE58 0 PAGE20F2 J \'" g) . o . ~ o --- cl o ~/ NOTE 10 h ~ .~ o O' ~, :== ~ NOTE 5 ~ NOTE u", PLAN ~ NOTE 7 \ - ~ V""' 'fI:':''''''''"'~'''''',""_:m-~gf,J1i'' ~ OJ'lSl5lSlSUt L I IF 118' ;"~l' ,"'!! =1" "'" - ~~,~,: i'l~ ~ .. -"," " ,'J~.~t)G -' _ r)ll, 110 0,,0_ 0 ! cl ~!~ I ~ l[ ...:...- iNOTE 10 ~ h ~ cl/' NOTE 8 ~ ~=~NOTE 5 NOTE 6------.... IIE=ill=li'='iIEil~~ -, I H I '=ill=ill=.llE11 F "'-=IIE;:n:IfTJhIr,.!l~ ELEVA TION REFERENCE STANDARDS: o = EWES remote reader and touch pad (provided by EWES), = SUS standard for remote register (provided by contractor). REGIONAL DESIGN STANDARD EUGENE WATER 8. ELECTRIC BOARD. EUGENE. OREGON SPRINGFIEI 1 liT L1~~' a(,)A:~'1. SPRINGFIELD, OREGON .1 I III I I . I III I FEe 01, 97 REV. DETECTOR DOUBLE CHECK ASSEMBLY , WD6-6.5700 1 21/2-10", BELOW GROUND EWEB ENGINEERING REVIEW~ AI..l ./ STANDARDS COMMITTEE APPROVAL ~ FEB 01. 97 FF11 DE49 REV. o PAGE 1 OF 2 SUB ENGINEERING REVIEW ~ I NOTES: . . 1. Detector double check vaulenclosurB shall be installed at point of se , or in an alternate loc~tion approved by EWEB or SUB for their respective service area, but no more than 10 fBet from point of service. 2. Detector double check assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4. or smaller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3. All clearances apply to outside and ir.-building installations. 4. Insulation - freeze protection to be insulation and/or heat source!o keep enclosure at a minimum temperature of 400F (NFPA 13-4-5,4.1,1). 5, Bore-sighted drain to daylight is required for all Springfield installations. Alternate methods may be approved by EWEB for devices in its service area. Allowable alternatives may include: A) dry well B) sump pump 6, Compacted gravel or undisturbed base. 7. Hatch, minimum 3' x 3', spring assisted, galvanized or aluminum diamond plate. 8. All assemblies 2112. and larger shall have flange supports. 9. Assemblies installed below ground level shall have watertight plugs or caps installed on the test cocks. 10, Watertight grout will be used to seal openings, 11, If vault depth exceeds 4', use OSHA approved ladder (OAR CH 437, Division 2, 1910.27). 12, Reinforced concrete vault (ASTM C-875). 13, Fire department pumper connection per local fire code. ITEM 1 = Approved detector double check assembly including factory supplied shutoff valves. - , REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON FEB 01, 97 REV. DETECTOR DOUBLE CHECK ASSEMBLY, 21/2-10", BELOW GROUND FEe 01, 97 FF11 DE49 REV. o. WD6-6.5700 1 PAGE20F2 J . . ---- \" g) <I o . <l " ;; , ~ N <I .0 . J NOTE 10 ~ ,$-'~ .: "'- NOTE 5 o h , " N _ - " c NOTE 13 ~ or:- ~ o 1 I~ 1~" MIN 1.0 EACH ~ IE:~O:;lla: , ,I l:t I '* I <l , PLAN NOTE 7 \ \ JNOTE '~ iR I I r::,m~;;;=m:=!m=m"'m!!:if~~~' L n~1 ' _E,,~ "L '- 1 -NOTE 12 j\NOTE 9~ _ I. \ :) /NOTE 10 I U-1~- ~ ,,--d-W I ][ "-0 I := ~ NOTE 5 ,j / o IEII Frrem=l =118 . . I Ell ::11 E 51UUlSUliL '1<=" ;0 , 0'1' '9 / CO/NOTE" , h <I NOTE 6------.... NOTE 3~' 11I=:111=:111=:IIE(Ie:::IT~ -"1=:111=:111=:11 Ell Ell F "-=;II=:IIF!IEIIE' "~rr=llr- ELEVA TION REFERENCE STANDARDS: [A] = EWEB remote reader and touch pad (provided by EWES), = SUB standard for remote register (provided by contractor). REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE. OREGON SPRINGFIEl.D UTILITY 1~(1A'lI1- SPRINGFIELD, OREGON I I . I IlL I APR 25, 97 REV. WD6-6.5730 0 DETECTOR DOUBLE CHECK ASSEMBLY, 21/2-10", BELOW GROUND AMES SS/SE PATTERN APR 25. 97 REV. FF11DE59 _ 0 EWEB ENGINEERING REVIEW 11\ ~ STANDARDS COMMITTEE APPROVAL ~ PAGE 1 OF2 SUB ENGINEERING REVIEW ~ NOTES: 1, Detector double check vaulenc10sure shall be installed at point of see or in an alternate I~cation' approved by EWEB or SUB for their respective service area, but no more than 10 feBt from point of service. 2. Detector double check assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4" or smaller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3. All clearances apply to outside and in-building installations. 4. Insulation _ freeze protection to be insulation and/or heat source ~o keep enclosure at a minimum temperature of 400F (NFPA 13-4-5.4.1,1). 5. Bore-sighted drain to daylight is required for all Springfield installations. Alternate methods may be approved by EWEB for devices in its service area. Allowable alternatives may include: A) dry well B) sump pump 6. Compacted gravel or undisturbed base. 7. Hatch, minimum 3' x 3', spring assisted, galvanized or aluminum diamond plate. 8. All assemblies 2 112" and larger shall have flange supports. 9. Assemblies installed below ground level shall have watertight plugs or caps installed on the test cocks. 10, Watertight grout will be used to seal openings. 11. If vault depth exceeds 4', use OSHA approved ladder (OAR CH 437, Division 2, 1910.27). 12. Reinforced concrete vault (ASTM C-875), 13, Fire department pumper connection per local fire code. ITEM 1 = Approved detector double check assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD, OREGON APR 25. 97 REV. DETECTOR DOUBLE CHECK ASSEMBLY, 21/2-10", BELOW GROUND AMES SS/SE PATTERN APR 25, 97 FF11 DE59 REV. o WD6-6.5730 0 I PAGE 20'? I . ~ I b I i/ ~.~ ~ ~ ~t---y,,-.-~~:~ . . '" .". NCTE 11 ~NC1E 7 NOTE U ~ PLA~I NOTE 7 \ _~ rNOTE1~ IEil6~l1=1" 4.f: I II ~='1T='1T:;iTi=iTi=Tii='iTi=lT':;ifF'::" i!!:'iTf' '1!ii'l'1 . . ." ..~ 'fT" 11g!'.':2IUUIlISUL ::l .i:: ','=r!Mm IlEI' ~ NOTE 9 ~ ""l,I3; 1 ," :llr- _I' ~'- NOTE 4 'if . " l-i- f~1 NOTE 9'. . ~-~~ . -NOTE12 , ", I . 0 ~__~ I ~\ ~;tA~'~ \l(~~ I !II.~ ~~ 112" MIN ~. -~ '-'''~ :~~,1 I' E-l.CH h .A !::""-- -~ END n7}~ ~Il:\-tjt W !d ~.> II n :e., 1 e. N~ -:0 " p I I J] g) l" D . , c '- ~ I:: ':1 'll - N " - :0 o '. . . " ..../ ..J NO IE 6----........ N01[ a~ ELEV,~ liON REFERENCE STANDARDS: GJ = EWES remote reader and touch pad (provided by EWES), = SUS standard for remote register (provided by contractor), . 4- ," . == ~NOTE 5 ~ Ii ~ ~NOTE 10 z :; , ~ '" " . ."", . ~ INOTE '0 ~ ~ :~.= ~ NOTE 5 111=!IEIII=!II=III~i1~ji -"I=III=III=III=III=IIF "-=111=111=111='11:" "-::IIt:..LII~ REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON APR 25, 97 REV. WD6-6.5740 0 DETECTOR DOUBLE CHECK ASSEMBLY, 21/2-10", BELOW GROUND FEBCO N PATTERN EWEB ENGINEERING REVIEW~ STANDARDS COMMITTEE APPROVAL ~ PAGE 1 OF 2 APR 25. 97 REV. FF11DE60 0 SUB ENGINEERING REVIEe I ! ! 1- NOTES: . . 1. Detector double check vaulenclosure shall be installed at point of se , or in an alternate loc~tion' approved by EWES or SUB for their respective service area, but no more than 10 feet from point of service. 2. Detector double check assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4" or smaller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3, All clearances apply to outside and in-building installations. 4. Insulation - freeze protection to be insulation and/or heat source.~o keep enclosure at a minimum temperature of40oF (NFPA 13-4-5,4,1.1). . 5. Bore-sighted drain to daylight is required for all Springfield installations. Alternate methods may be approved by EWEB for devices in its service area. Allowable alternatives may include: A) dry well B) sump pump 6. Compacted gravel or undisturbed base. 7. Hatch, minimum 3' x 3', spring assisted, galvanized or aluminum diamond platB. 8, All assemblies 2 112" and larger shall have flange supports. 9. Assemblies installed below ground level shall have watertight plugs or caps installed on the test cocks. 10. Watertight grout will be used to seal openings. 11. If vault depth exceeds 4', use OSHA approved ladder (OAR CH 437, Division 2, 1910.27). 12. Reinforced concrete vault (ASTM C-875). 13, Fire department pumper connection per local fire code, ITEM 1 = Approved detector double check assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD I EUGENE WATER & ELECTRIC BOARD. EUGENE OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON' I I APR 25, 97 REV, WD6-6.5740 0 DECTECTOR DOUBLE CHECK ASSEMBLY, 21/2-10", BELOW GROUND FEBCO N PATTERN APR 25, 97 FF11 DE60 REV. o PAGE20F2 . . Y NOTE 4 NOTE 7 . NOTE 5 / I I glOOOOO . t) ~ } )::: =J , Z N - - '" PLAN ;fIJlII JIJlU JIJlII jll[lllllllllll- ;f IJ III i 1.1 'I J UJ 1111 1.1 II Jill I11I II j I J 1 1]1 J 11.1 II J 11.1 ) I J I U ) I J I 1.1 Illi 1.1 11)1 II j I J I ,J,I.,I !I ,1,1,1) ,)1,1,1,1) ,11,1,1,1.,1,)1,1,1.1.1 "II ,1,1.1.1 "II ),i,U ,)11,1" ~ ~ ' /~... - z ...-/ " NOTE J ~ NOTE 9 =:J =:J -:> "'. 12' MIN NOTE 10 ~_) I EACH ENO X' /:, '; NOTE 5 \ II' r ~m~m~ITI~fii-)' ''=111=:111=:111= '-"I--:I'~ " ~ 1 ~ I 0-0 0-011 JJt\ I ~~l~~ _ Jt I /' ~~IT~m~m~r NOTE 8 ~ ~ 1111=:111=:111:;:' NOTE 6J ~"r-I"~' 1-' ~ ELEV A TION REFERENCE STANDARDS: ~ = EWEB remote reader and touch pad (provided by EWEB). = SUB standard for remote register (provided by contractor). REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON FEe 01, 97 REV. DETECTOR DOUBLE CHECK ASSEMBLY, FEB 01, 97 WD6-6.5800 1 21/2-10", ABOVE GROUND FF11 DE50 REV. o EWEB ENGINEERING REVIE~./1AI.L--- STANDARDS COMMITTEE APPROVAL___~ PAGE 1 OF 2 SUB ENGINEERING REVIEW~ .I .' NOTES:. ..., . 1. DBtBctor double check vau enclosure shall be installed at point of se., or in an altBrnatB location approved by EWES or SUB for their respective service area, but no more than 10 feet from point of sBrvice. 2. Detector double check assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4" or smaller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3. All clearances apply to outside and in-building installations. 4. Insulation - freeze protection to be insulation and/or heat sourceJo keep enclosure at a minimum temperature of 40'F (NFPA 13-4-5.4.1,1). 5, Bore-sighted drain to daylight. 6. Compacted gravel or undisturbed base. 7. A door or other access shall be provided. 8. All assemblies 2 112' and larger shall have flange supports. 9. All structures to comply with local codes. 10. Fire department pumper connection per local fire code. ITEM 1 = Approved detector double check assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTIIIITY BOA.RD- SPRINGFIELD, OREGON I iJ .1_ 1111 I. FED 01, 97 REV. DETECTOR DOUBLE CHECK ASSEMBLY, 21/2-10", ABOVE GROUND FEe 01, 97 FF11 DE50 REV, o WD6-6.5800 1 PAGE 2 OF 2 1 .' """ ~/""" /""e \ gJbOOOO' Ivl NOTE 9 \~ \ g Z ,-:J ::€ I " ~=~ = =rM- ~ )I -flJ ,m ):::=] . Z N - - '" PLAN NOTE 9 '"""'" \~ .\ ) NOTE 5~.. I /II U IJ 11.1 T 1.1 II JT IJ lilT 1.1 Ii jT 1,1 II IT ~ 11 1.1 II J I 1.1 Jill II 11.11 II till It 11.11 II j I Ji 11 t II 1.1 II J I II I111 II 11,11 II 11.11 II II Jill I1I1 /,~ ,I,I! 1,1.,1,1,1 ,! I ,l,L,JJ,11 ,1,1.i..1 ,j 1,.1,1,1,1 ,! 1,1,1,1,1,) 1,.1,i, 1,1, I !,i, 1)\ ~, ....z! NOTE "------ ; I 1 I-I. ,;~""~~o ~Ar . -~ F1 ~/ U l'Ulb I ~~~"'~ J[ ;> I' ;::, :0 ='5 ~m"m'm:::::TTi '-::IIDIDII= "-1'1--:1". p /./ NOTE 8~ /' NOTt: 6 J ~rr~rrEm:-,r 'I "=11 EWI::-' ~1I1=1l1 . "'-- ~ ELEV,,,- TION REFERENCE STANDARDS: GJ = EWEB remote reader and touch pad (provided by EWES). = SUB standard for remote register (provided by contractor). , , REGIONAL DESIGN STANDARD F.UGENE WATER & ELECTRIC BOARD. EUGENE OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD, OREGON I APR 25, 97 REV. DETECTOR DOUBLE CHECK ASSEMBLY, APR 25. 97 WD6-6 58300 21/2-10", ABOVE GROUND FF11 DE61 . AMES SS/SE PATTERN REV. o EWEB ENGINEERING REVIEW~A....L/ STANDARDS COMMITTEE APPROVAL ~ PAGE 1 OF 2 SUB ENGINEERIN~ REVIEW ~ .. NOTES:. .... 1. Detector double check vault closure shall be installed at point of se~r in an altern~te location' approvBd by EWEB or SUB for their respective service area, but no morB than 10 feBt from point of servicB. 2. Detector double check assembly may be installed vertically, provided that the assembly: A) is internally spring loaded (not weighted checks) B) is 4. or smaller C) is recommended by the manufacturer for vertical installations D) has the normal flow upward 3. All clearances apply to outside and in-building installations. 4. Insulation _ freeze protection to be insulation and/or heat source,t.o keep enclosure at a minimum temperature of40oF (NFPA 13-4-5,4.1.1). . 5. Bore-sighted drain to daylight is required. 6, Compacted gravel or undisturbed base. 7. A door or other access shall be provided. 8. All assBmblies 2 112. and larger shall have flange supports, 9, Fire department pumper connection per local fire code. ITEM 1 = Approved detector double check assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD. OREGON I APR 25, 97 REV. DETECTOR DOUBLE CHECK ASSEMBLY, 21/2-10", ABOVE GROUND AMES SS/SE PATTERN APR 25, 97 FF11DE61 - REV. o WD6-6.5830 0 PAGE 2 OF 2 I -e . !z " - - ::> [i~=:,~ Jv II :; . , '....) "It" NOTE 9 j g " "" ,2J~()()()(), i NOTE 5 ~ NOTE . . , 0 ~ )::::=] ~ I "'- NOTE 7 PLAN J] I n 11_11111J In II II IT IIIII n I J II T ~ Lf I.IIIJU jl.li 1111.1'1 II jl,llllllJlU !I~,i,~ /f1,IIIIIIJiIIJlnIlIIIIIIJIIIIIJIIII~ ;1, I,) ) I ,I,i, I) ,) I ;',i,I,1 "II ,I,i, 1,1,) 1,1,1,1,1 ,! I ,IJ, 1,1,11 ,I,i, I) ,) I J,I,; " . g _./'~' r0 g ~ NOTE · ~ 1:- / j' -, 1;--r ~ ~ ~"lJ1t ,1-:~~1 r=~1 +t"~~ I W (ft~\ (&~! 12' MIN \~ &. \\~ I EACH END . p~~J,~J-__ '\ C'~r:\ _-.lL I I /'" ~ij'm"'iTi"m::" NOT" 8 ~, ICIICIII=-' c / 111=11'-' ,~O TE 6 - ~ NOTE 9" "" ,~) II 'r" ~m"m;"m"'ii' 'J '::11 t=l1 CI 11= ''-''1--:11'- , p }~ ELEV,uTIOI\j REFERENCE STANDARDS: ~ = EWEB remote reader and touch pad (provided by EWES). = SUB standard for remote register (provided by contractor), REGIONAL DESIGN STANDARD , EUGENE WATER & ELECTRIC BOARD. EUGENE OREGON SPRINGFIt=' n \I-rll,',~r l~OARD. SPRINGFIELD, OREGON ... ll_111 I I I APR 25, 97 REV. DETECTOR DOUBLE CHECK ASSEMBLY, APR 25. 97 REV. WD6-6 58400 21/2-10", ABOVE GROUND FF11 DE62 0 . FEBCO N PATTERN EWEB ENGINEERING REVIEW ~ SUB ENGINEERING REVIEw@.. STANDARDS COMMITTEE APPROVAL ~ PAGE 1 OF 2 . NOTES:. ..' . . 1. Detector double check vault closure shall be installed at point of se~or in an alternate location approved by EWEB or SUB for their respective service area, but no more than 10 feet from point of service. 2, Detector double check assembly may be installed vertically, provided that the assembly: A) is intBrnally spring loaded (not weighted checks) B) is 4" or smaller C) is recommended by the manufacturer for vertical installations 0) has the normal flow upward 3. All clearances apply to outside and in-building installations. 4, Insulation - freeze protection to be insulation and/or heat source ~o keep enclosure at a minimum temperature of40DF (NFPA 13-4-5.4.1,1). . 5. Bore-sighted drain to daylight is required. 6. Compacted gravel or undisturbed base. 7, A door or other access shall be provided. 8. All assemblies 2112" and larger shall have flange supports. 9. Fire department pumper connection per local fire code, ITEM 1 = Approved detector double check assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BO- ~D - SPRINGFIELD. OREGON " APR 25. 97 REV. DETECTOR DOUBLE CHECK ASSEMBLY, 21/2-10", ABOVE GROUND _ FEBCO N PATTERN APR 25, 97 FF11 DE62 REV. o WD6-6.5840 0 PAGE20F2 .. . . . . ., . . . " .. Z N :1 . ,- .. ~ -, ., I I '.0 .0 ~Z .0 - :1 "0 '.0 .'. :3)OOnnn, J '. , .. . , " . NOTE PLAN 4 ,/ NOTE 7 ~" . , ri . . ". ,/NOTE 5 -~=a ~ r GROUND LEVEL )),,~~~IS;. ~ /"'<<~~ ,/ , / NOTE 7 , .. r I. , ,m.i(fIS[fL ~ NOTE 4 J ..J' Rv\V<,,f.': I . /''/)>:1/" , . /,~~, .~~ .'W~' ~'<<'/ ., ~ , 6" MIN 24" MAX - 3", i""' I II " 0' . I ::;/"" , z :1 N - , . , ELEVA TION NOTE 6/ ~ REGIONAL DESIGN STANDARD EUGENE WATER 8. ELECTRIC BOARD - EUGENE, OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON , FEe 01, 97 REV. WD6-6.6100 1 REDUCED PRESSURE BACKFLOW ASSEMBLY. 1/2-2", BELOW GROUND EWEB ENGINEERING REVIEW~ STANDARDS COMMITTEE APPROVAL ~ PAGE 1 OF 2 FEB 01, 97 REV. FF11DE51 0 SUB ENGINEERING REVIEW e.. NOTES: 1. Reduced pressure backflow ass. shall be installed in a location approvB~WEB or SUB for their. respective service area, and shali"lr'~bove the 100-year flood plain. .. 2. Reduced pressure backflow assembly shall be installed horizontal and plumb. 3. All clearances apply to outside, in-building, and vault installation. Minimum clearances for device assemblies 2 inches or smaller may be reduced provided they are accessible for testing and repairing and EWEB or SUB approves the variance for their respective service area. 4. Insulation _ freeze protection to be insulation and/or heat source to keep enclosure at a minimum temperature of40oF (NFPA 13-4-5.4.1.1). 5. Assembly enclosure shall include a core-sighted drain to daylight capable of draining a full relief valve discharge (length of drain to be approved by EWEB or SUB for treir respective service area,) 6. Compacted gravel or undisturbed base, . 7. Device enclosure _ (E.G., meter box, irrigation control vault, or fabricated permanent enclosure). ITEM 1 = Approved reduced pressure backflow assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE. OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD, OREGON FEB 01. 97 REV. REDUCED PRESSURE BACKFLOW ASSEMBLY, 1/2-2", BELOW GROUND FEB 01,97 FF11DE51 WD6-6.61001 PAGE 2 OF 2 REV. o z :i ~. .!;/;':~:'~, Ft-----;#J r ' / I , / I I ,/ I I /, / , I 6u/ 'I -i~ _~O l@Bl ~ . ~N~TE4 , (J(j U 11< c; c-' Il. , .. N ~ E--- ~=;:(=] . . ~NOTE 9 (TYP) , ' . i \NOTE 5 PLAN NOTE 11 ~ , : (NOTE 10 '. / NOTE 7 / NOTE 4 Il. 0~)'>i~,W-;)); ...'Y')..y)-.yWWW~Y>.J .J( I "~'''}~'.;'''Y'':>.Y~Y'Y''V':V'':Y''''t;.N:-''Y':V:\Y'''~;''Y,,~~ 'I"" '~~~' "''0:'...,' ,0~ . .'. 4 I I . .' ,.. : ,~'" , f<(;(. ~ i{I......~'Xf,~ I(, ~., 'B . '!;(~,7"'..1 ;.,t~ ~ - 0N)(Jl.)t<2l.... '~"''(, o' J[ ~ ~ 12"~IN ~ ~ ~ EtNCt I~. ~ ^ . 5. I') fr~)~6!I'U L'~rL~ ",Ix uJ--lJ _ L\ J[ ~:~ _~ 4-. .. \ ." .. ~ ~ NOTE 8 ~ NOTE 9 _~ (TYP) /~ l ~ NOTE 5 1 . j ....~ NOTE 6 ELEVA TION REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE. OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON I FEe 01, 97 REV. REDUCED PRESSURE BACKFLOW ASSEMBLY, 2 1/2-10", BELOW GROUND EWEB ENGINEERING REVIEW ~""..L/ STANDARDS COMMITTEE APPROVAL ~ PAGE 1 OF 2 FEB 01, 97 REV. FF11DE53 0 SUB ENGINEERING REVI~ WD6-6.6400 1 NOTES: 1. Red'uced pressure backflow emblY shall be Installed in a location appre by EWEB or SUB .for iheir respectivB servicB area, and shall be above the 1 OO-YBar flood plain. 2. Reduced pressure backflow assembly shall be installed horizontal and plumb. 3. All clearances apply to outside, in-building, and vault installations, 4. Insulation _ freeze protection to be insulation and/or heat source to keep enclosure at a minimum temperature of 400F (NFPA 13-4-5.4.1.1). 5, Assembly enclosure shall include a bore-sighted drain to daylight capable of draining a full relief valve discharge (length of drain to be approved by EWEB or SUB for their respective service area). 6. Compacted gravel or undisturbed base. 7. Hatch minimum 3' x 3', spring assisted, galvanized or aluminum ~iamond plate, 8. All assemblies 2 112" and larger shall have flange supports. 9. Watertight grout shall be used to seal openings. 10. If vault depth exceeds 4', use OSHA approved ladder (OAR Ch 437, OMsion 2,1910.27). 11. Reinforced concrete vault (ASTM C-875). ITEM 1 = Approved reduced pressure backflow assembly including factory supplied shut-off valves. REGIONAL DESIGN STANDARD ~ EUGENE WATER & ELECTRIC BOARD _ EUGENE OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD. OREGON " FEB 01.97 REV, REDUCED PRESSURE BACKFLOW ASSEMBLY, 2~1/2-10", BELOW GROUND FEe 01, 97 FF11 DE53 REV. o WD6-6.6400 1 PAGE20F2 .. ., -- r3" MIN . l~ "l ~~ ((L1~ I e- ,,----- ._- t_____ ___ () NOTE 4 .0 =:::J =:::J =:::J =:::J aJliOQliO\ ~ PLAN ~~ ::; - ( ) --- ------. ,\ ___ _____\.1 :::\,,~ , / NOTE 7 zl ,~I <0, ~A ,I I , I I t A I I I~ ~~ - i' I Z x , "iO'" -" , / NOTE 6 ",. -'" %',,%v/.,/ J,Ii ~//'",%v';:;'/,/,v ~ ~,*,,*:~<<<'Y~~%~~%%%~~1<~%-'t~ ~~' >>~~%'%.'%.'*W ,'<<<<<~ /.,\:%,\:/(y..-<V^'//' ?~~~~~ ~~~'V>>'<; ~,/, ,. h 1/ ELEVA TI01\1 ::: 1 "" , 'f;%~:{f;.{f/ <<:~~,v~ "y>>y ~I ~ REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE. OREGON SPRINGFIELD UTILITY BOARD. SPRINGFIELD, OREGON I FEe 01, 97 REV. REDUCED PRESSURE BACKFLOW ASSEMBLY, 1/2-2", ABOVE GROUND WD6-6.62001 EWEB ENGINEERING REVIEW~ STANDARDS COMMITTEE APPROVAL~ PAGE 1 OF 2 FEB 01, 97 REV. FF11DE52 0 SUB ENGINEERING REVIEW e.. NOTES: . 1. Red'uced prBssure backflow .blY shall be installed in a location appr.bY EWEB or SUB for ihei; respective service area, and shall be above the 1 OO-year flood plain, 2. Reduced pressure backflow assembly shall be installed horizontal and plumb. 3. All clearancBs apply to outside, in-building, and vault installations. Minimum clBarances for device assemblies 2 inches or smaller may be reduced provided that they are accessible for testing and repairing and EWEB or SUB approves the variance for their respective service area. 4, Insulation - freeze protection to be insulation and/or heat source to keep enclosure at a minimum temperature of40oF (NFPA 13-4-5.4.1.1), 5. Assembly enclosure shall include a bore-sighted drain to daylight capable of draining a full relief valve discharge (length of drain to be approved by EWEB or SUB for t~eir respective service area). 6. Compacted gravel or undisturbed base, ' 7, Device enclosure - (E.G" meter box, irrigation control vault, or fabricated permanent enclosure), ITEM 1 = Approved reduced pressure backflow assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD. OREGON I FEB 01, 97 REV, REDUCED PRESSURE BACKFLOW ASSEMBLY, 1/2-2", ABOVE GROUND FEe 01, 97 FF11 DE52 REV. o WD6-6.6200 1 PAGE 2 OF 2 .. , NOTE 5 -./ e( NOTE 4 , ~OOOlJdL '0 o::J o::J z :> ~ NOTE 7 , .. N ~=:~I ( PLAN . ) --J /IIJlIIIIJTlIIIITlI1IlTIIIITTTI\ !1 I J II I i IJ 11.1 i I j II J1 II i I II II III i Ii ~ NOTE 9 /U U 111IIII1111111 IIIII1 Illi II Illi II \ ;1l]11Ti11 Illilllllll.llllllllllilllllili, /1 I l I " !! I , " . I I I " I I I , " I I I I " I I I I " . I I.... " \ I "" '-... .f7o+, 2 "'-NOTE ~ ~ =:> _I ,~I '" ~ ~~ ';t,~~'l~ ~ R. (]~~b (J[ .~~ ~~ JC 'J: 1 '~:!!~~~~~I \ " ~l '-'11=;11-::- "- NOTE 8 '\. h '- "OTE 6 NOTE 5 ~ , ELEVA TION ~ i;; i i;;;ii"Eii"E =J11311311:? "'1;:--11'-" y REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD. EUGENE, OREGON SPRINGFIELD UTILITY BOARD - SPRINGFIELD, OREGON FEe 01, 97 REV. WD6-6.6500 1 REDUCED PRESSURE BACKFLOW ASSEMBLY, 21/2-10", ABOVE GROUND FEB 01, 97 REV. FF11DE54 0 SUB ENGINEERING REVlEW@ EWEB ENGINEERING REVIEW ~~ /U,..L-- STANDARDS COMMITTEE APPROVAl:'...l!"":. PAGE 1 OF 2 . NOTES'. .. 1. Reduced pressure backflow mbly shall be installed in a location appr by EWEB or SUB for their respective service area, and shall be above the 1 OO-year flood plain. 2. Reduced pressure backflow assBmbly shall be installed horizontal and plumb. 3. All clearances apply to outside, in-building, and vau~ installations. 4. Insulation _ frBeze protBction to be insulation and/or heat source to keep enclosure at a minimum tBmperature of 400F (NFPA 13-4-5.4.1.1). 5. Assembly enclosure shall include a bore-sighted drain to daylight capable of draining a full relief valve discharge (length of drain to be approved by EWEB or SUB for their respective service area). 6. Compacted gravel or undisturbed base. 7. A door or other access shall be provided. 8. All assemblies 2 112" and larger shall have flange supports. 9. All structures to comply with local codes. ITEM 1 = Approved reduced pressure backflow assembly including factory supplied shutoff valves. REGIONAL DESIGN STANDARD EUGENE WATER & ELECTRIC BOARD _ EUGENE, OREGON SPRINGFIELD UTILITY BOAR[' - SPRINGFIELD, OREGON FEB 01. 97 REV. WD6-6.6500 1 REDUCED PRESSURE BACKFLOW ASSEMBLY, 2 1/2-10", BELOW GROUND FEe 01, 97 FF11 DE54 REV. o PAGE20F2 . ,. . WATER DESIGN STANDARDS SERVICES SECTION TITLE NAME AIRGAP BACKFLOW PROTECTION ATMOSPHERIC VACUUM BREAKER PRESSURE VACUUM BREAKER ASSEMBLY DOUBLE CHECK VALVE ASSEMBLY, 1/2-2", BELOW GROUND DOUBLE CHECK VALVE ASSEMBLY, 1/2-2", ABOVE GROUND DOUBLE CHECK VALVE ASS~XBLY, 2 1/2-10", BELOW GROUND DOUBLE CHECK VALVE ASSEMBLY, 2 1/2-10", BELOW GROUND ~~ES SS/SE PATTE~~ DOUBLE CHECK VALVE ASSEMBLY, 2 112-10", BELOW GROUND FEBCO N PATTER.."l DOUBLE CHECK VALVE ASSEMBLY, 2 1/2-10", ABOVE GROUND DOUBLE CHECK VALVE ASSEMBLY, 2 1/2-10", ABOVE GROUND AMES 55/SB PATTE~l DCUBLE CHECK VALVE ASSEMBLY, 2 1/2-10", ABOVE GROUND FEBCO N PATTERN DETEC70R DOUBLE CHECK ASSEMBLY, 2 1/2-10", BELOW GROUND AMES SSISE PATTERN DETECTOR DOUBLE CHECK ASSEMBLY, 2 1/2-10", BELCW GROUND ~~S SSISE PATTE~~ DETECTOR DOUBLE CHECK ASSEMBLl, 2 1/2-10", BELOW GROUND FEBCO N P.'-.TTERN DETECTOR DOUBLE CHECK ASSEMBLY, 2 1/2-10", ABOVE GROUND DETECTOR DOUBLE CHECK ASSEMBLY, 2 1/2-10", ABOVE GROUND AMES 55/sE PATTE~"l DETECTOR DOUBLE CHECK ASSEMBLY, 2 112-10", ABOVE GROUND FEBCO N PATTERN REDUCED PRESSURE REDUCED PRESSURE REDUCED PRESSURE REDUCED PRESSURE BACKFLOW ASSE}ffiL'{, Bi\CKF'!.OW ASSEMBLY l BAC:<FLOW ASSEMBLY, BACKFLOW ASSEMBLY, 1/2-2", BELOW GROUND 1/Z-2", ABOVE GROUND 2 1/2-10", BELOW GROUND 2 1/2-10", ABOVE GROUND . STANDARD NUMBER APPROVAL REV DATE W06-6.2000 FEB 01, 97 1 W06-6.JOOO FEB 01, 97 1 W06-6.4000 FEB 01, 97 1 W06-6.5100 FEB 01, 97 1 W06-6.5200 FEB 01, 97 1 W06-6.5400 FEB 01, 97 1- W06-6.54JO APR 25, 97 0 W06-6.5440 APR 25, 97 0 W06-6.SS00 FEB 01, 97 1 W06-6.55JO APR 25, 97 0 W06-6.5540 APR 25, 97 0 W06-6.5700 APR 25, 97 0 W06-o.57JO APR 25, 97 0 W06-6.5740 APR 25, 97 0 W06-6.5800 FEB 01, 97 1 W06-6.58JO APR 25, 97 0 W06-6.5840 APR 25, 97 0 W06-6.6100 FEB 01, 97 1 W06-6.6200 FEB 01, 97 1 W06-6.6400 FEB 01, 97 1 WOO-6.6500 FEB 01, 97 1 , . . THIS PAGE LEFT INTENTIONALLY BLANK