Loading...
HomeMy WebLinkAboutBuilding Field Test & Inspection Report 2009-8-28 I. rtl~;lInformation ,.,..,. .To Build On Engineering . Consulting. Testing ~ -, DAILY FIELD REPORT Date Performed: August 28, 2009 Report Number: 722-90125-1 Client: Derek Verdoorn Project Name: 30Ton Co. Tank Replacement Carbonic Systems Incorporated 2187 South F. SI #M Project Location: 2187 South F, Street A Springfield, OR 97477 Springfield, Oregon Contractor: Ordell Construction Building Permit No.: COM2009-00985 Fabricator: Ordell Construction Shopl Field: Shop Type of Inspection: Welding Weather: Partly Cloudy' Field Observations and Comments Performed weld inspection on #8 rebar to embed plates (4 total) as noted on sheet S2, Fit~up of weld joints were inspected for workmanship, In Progress welding was monitored to the fabrications FCAW welding procedure specifications, Weldments were inspected for size, length, profile and locations, To the best of our knowledge, the work inspected is in conformance with design drawings dated 9/25/09, specifications letter from engineer and applicable D1.4 codes, Contractor was asked to notify our office when additional services are needed, Inspector: David F. Smith, Certification No.: 0877340-85 CBB #176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649, Respectfully SUbm~~~dlf L fess/anal se~!-~ Inc. cc: City of Springfield THIS REPORT IS PROVIDED FOR THE INFORMA TION OF THE CLIENT ONLY. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY RY ANY MFANc; r=}(r.FPT IN FI III WITI-/O/ITTHF WRITTF.N P!=RMISSION OF PROFESS/ONAL S~DVIr.F INrJUSTRIF."'I IS PROHIBITED Professional Service Industries, Inc.. 1040-A Shelley Street. Springfield, OR 97477. Phone 541/746*9649. Fax 541/746-7163