HomeMy WebLinkAboutPermit Electrical 1990-3-13
Rece-:.pt #
!-.(/l tJ. <) '"
.. RESlDalTlAL"
APPLICATW/PERMIT
225 North 5th Street
SpringfieZd, Oregon 97477
BuiZding Division
726-3753 .
Job Location, Ff\- ~ \J \ly-tD\\ tcUR .'
A.a...o,s Map # \ "~'=)A 1_C) \ 8 T= rk\ # 0 \ \ \C1
Subdivision:
.
c;~
I .
I>>n", \\')\ \"\ ~r'l\ ~ nf)~,- ~~ \ 01\'(l+\ \) Q W
Addr..s:4?, \\ n S FA lAJ\. \\{\Pr~e: l o~4 -\('fll
City: \\\ \ ~ \.01 \ Q Y ~ 0_ \ ' ~. . / Zip: C\ f\ Q Jj 9,
n
n
n
n
NI"'I.l
Describe ll'ork:
Addi tian
~Q~
Remodel
:.!obila Homa
~~~ lR-<=10
Valua
1\ 1(1)
~te of Application
Contractors
General
;Plumbing
i Hechanical _ _ . ~
I :~::~~:~g~l~:~~~1 ~~~~ ~1.);~()~~44 ~~b
It i. tho ,..ponoibility of tht/ ;e'rnn.t ~.,. to .'} that alt insp.ctio718 are mads at thB propBl' tim~, that each ::Mrs.. i. ,sadab,.
11'OIT/ ths street, and that the perrrrit card is locat'la at the front of th8 prt:perty.
ABuilding o-;vicion approt:ed plan shall remain on tha Buildirlfl Sit:; at aU timBS.
,PROCEDURE FOR TNSPECTION R~QUEST:CALL 726-3769 (rccorder) state your City designated job numbero, job addrcss, type of in3pBc~icn
requested ar.d when you win be ready for inspection, Contractors or OI.mers ncme and Fhone number. Requests received befere 7:00 a:':1
:.nIl bB made thG samB day, requests made a~ter 7~OO am r.riU be made th.e nczt :.JOrking day. 01 Q 1\/1.
. Your City Desigr.ated Job Number Is: C ~I /, - nr-t
Reoui1"P-d Tns'tMctions
O SITE INSPECTION: To be l1Klde aft"
excavation, but prior to set up of
form.. - -1....
rn UNDERSLAB PLUMBING.!riECTRICAL J
~CHANICAL: To be lMzde_befozoe- any
worole is OJOlJcrod.
o
FOOTING ~ FOUNDATION: To be ""ds
aftor trenches are excavated and
forms are eroected, but prior to
pouring cencreto.
0, . UNDeRGROUND PLUMBING. SEWER. W.1TER,
DRAINAGE: To be rrrule prior to fil.-
.1. ir'.g trtmCM8.
O UNDE.~FWOR PLU/.$ING & MECHANICAL:
, To be mad.e prior to insta llation of
floor insulation or decking.
O POST AND BEAM: To be made prior to
instaHation of floor inst.:Zation or
decki,,". -~
rTL IY!UGH PLmmItlG. E~L- 1& MECH-
L.:J"" ANICAL: No :Jerk tis to by/covered
.untiL these inspe~have beer.
made and approved.
O FIREPLACE: Proior to pZacir.g facing
materials and before framing inspec-
tion.
o
FRAJfING: Mu.tJt be requetJted after
approval of rough plwr.bing, electri-
cal <I mechanical. AU roOfing
bracing t chimneys, etc. trr..tst be
. complBtcd. No !.XJrk is to be C011-
... cealed until thia inspection has
. bB~n made and approved.
"
Addre~s
. .Lige. II'
Bldrs Board Rerr.
Phnnp
O lN~'ULA'1'10NIVAPOR BARRIER INSPECTION:
To be m:zde after all insuk:.ti:m a:".d
. .' required vapor barriers are in place
'.:' ': but before any lath, gypsum boaJ'd or
wlZ cove1"ing is applied, and bsforos
. any inauZation is concealed.
o
DRYWALL INSPECTION: Te be made
aft8r aLl d:rytJall is in place,
but prior to any taping.
O MASONRY: Steel location, bo1u1
beamtJ, grou ting or vertica ls in
accordancB with U.B.C. Section
2415.
O WOODSTO'IE: Aft" inotalZation i.
ccmplet€d.
o
CURS & APPROACH APRON: After' forms
are erected but prior to pooPing
con.zrete.
jl'-P. ~
Siqr.ed: N)?ZD ).
Dat., . ~. I~ -Yf )
Expires
G{ !J5/QO
I DE/!OLITION OR gOVE!; S!JILDIi/CS
~ Sani:ary Se'..J6l' ::apped at p~op;;rt"~ lir.B
:=l Septie tank p-.c::ped and fiZZ~ vith gra~B"L
---, Final - rlhen above ite:ns arB completed
~ and when demolition is complete or struOJ-
ture moved and pr::r.naes OJlBaned up.
o
SIDF:WALK & DRlI'E:WAY: For all con-
crete paving within street Pight-
of-lX.y, to be made after all exca-
vating complete & form work & sub-
base material in pla::e.
I Nobi l.e Bem8S
:=J Blocking and Set-.p
:=J Plumbing connections -- s~er and ~~er
---, Electrical Connection - Slocking, Bat-up
~ and plumbing connections nr~st be approv8d
before requesting e!ec:rical inspec:io:,:
:J Accessol".:i Building
---, Final - Aft~r p:Jrcr.es, skirting, decks,
~ etc. are comple:~d.
o
All project conditions, such as the instaLlation of street trees, c~~lati~n of the
required landsccpir'.g, etc., must be satisfied before the SUILDIl.'C FINAL can be rsqusstad.
o FIlIAL PLUMBIIIG
~
: t~ilAL 11ECHANICAL
FINAL ELECTRICAL
o
FINAL BUILDING: The Final Building Inspection must be requ83ted alter tho Pinal Plumbing
Electroical, and Mechar.ical InspectiontJ have been made and approvad.
o
o
FENCE: When compl;;te -- Provide
gat8s or movable sections through
P.U.E. .
*ALL MANHOLES AND CLEANOUTS ~fUST BE ACCESSIBl.E, ADJUST:fE!~T TO BE t.~"DE AT NO COST TO CITY I Page 1 of 2
o
I
I JOB NO.
Ize"'.:
t'c:.gc "
SOLAR ACCESS REQ.- L-COG*
Occupancl/ Gr. Type/Cor.st: . Bedrooms:
WT TYPE I wt Paces - I I Enera.,u SOUI'CeB Tzroe
Interior I Setbacks I I Heat
I P.G. House l CCU'aqe l Access. I I Watel' Yf?atp.l'
Comer INorth I Range
Panhandle ,lEast i i : I FireD lace
Cut-de-sac ISouth I I Wood:J tave
IWest I I II
Lat Sq. Ftg.
:: >;[ lot CJfJel'ag;:
.II vf Stories
Total Height
I
I Topography
I
IITEN
lM1in
I Gc:raae
I Carvort
I Accessoru
-- Fees
.Bi~rl 0 I
, I
I
I
I
x
Value
Building Value & Permit
This permit io granted on the express condition that the said construction
shaU, in all. respects, conform to the Ordinance adopted by the City of
Springfield, including the Zoning Ordinance, regulating the construction
and UDe of buildings, and ma.y be Bucpended 01' revoked at c:ny time upon vio-
lation of any provisions of said Ordinances.
TOTAG VAWE
Is.D.c.
lvct.uc)
1.5 :r
*
Tota! r:ha..-ges
1*
!Plan Check Fee:
IDate Paid,
IRecdpt #:
I Signed:
Bui1.ding Pernrit
State Surcha:rge
lITEM
I Fi:z:tu:J.es
IResidentiaZ (1 bath)
I Sanitary Sewer
I Wate1'
I
I NO.
FEE
CHARGE
Plumbing
Pe r m i t
.
No person ahall construct, install, alter or change any new ar e=isting
plumbing or drainage system in ~hole or in part, unless such person is the
legal possessor of a valid plumber's license, except that a person may do
plumbing work to property which is owned, leased or operated by the appli-
cant.
lITEM
I Res. Sa.
J NO. I
FEE
I
I
I
I *
CHARGE I
ffi ~) I
I
.1
?)1).rorJ
L{() .CO
4,~
Y4.~*
Electrical Permit
Plumbing Pem t
State Surcr.apge
Total Charaes
fta.
New/Extend Circuits
Temporary Service I
QfD ,oM\'\~~. J
Ele:Jtrical Permit
Where State Law requires tr.at the electrical work be done by an Electrical
Contractor, the electrical portion of this pennit shall not be valid until
the label has been signed by the Elecmcal ~ontractor.
State Surcharae
Total Charaes
ITEM
I NO.
FEE
CHARGE
Mechanical Permit
Furnace ETU'S
Exhaust Hood
Vent Fan
I .
I iloodstOiJB
I
I
1
I.
I -- ENCROACHMENT -- I
I SeC".lrittl Deoo3it
I Storage I
I Maint~e f
lfu~t I
I Total Charoaes ~ ...
I Curbcu; I
I Sidew Zk I
I Fe~e ~ _______
I Electrical Label ~
1"",,"'- 1 _ "-- _
~~~~f\~~-\\.t\~t~-~-----~ I ~---~-Qc)
I_~_._ ^ ~I Signgd
~~!OUNT DUE,' --- \ ~<-\ Sf ~
Permit Issuance
Me::hanic:zl Permi t
State Surchcrae
Tnti'll CNz7or:JRR
Ptan Exam1..nel"
""ce
I HAVE CAREFULLY EXAN.INED the cOrtrpteted application for peromit, and do
hereby certify that a'Ll inforomation hereon is tl'Ue and correct, and I
f~rther certify that any ar.d aU work perlorn1ed shatz be do~e in accor-
dance ~th the Ordin:znces of the City of Springfield, and th~ Ur~B of tha
State of Oreg~n p~rtaining to the work described herein, and that NO OCCU-
PANCY will be rn::zde of any structure witho:J.t pamission of the Building Di.
vision. I further certify that o~ly cont1'Q::tors and e:rrpl"yees who are in
~pliance with ORS 701.055 will be used on this project
Date