Loading...
HomeMy WebLinkAboutSpecial Inspection Correspondence 1987-9-24 - ---,,-- - --- '. 'PRINGFIELD ~,.awaJ&, !. ~ r " CITY OF SPRINGFIELD g~nM,~ ~~iIol.lJ""IIlJll1::t1.'~ "-""\JI..u.t1l~ "';1, '; l_~lhl;".":"~~ ~ l:'~-~-"':"';::~ - .::.. ~ .~_.~.t;'~~i1"'" -'I . ArllJ.l~~-~ . ....a~,,~ .......:.:o.b~....J..... ,~ Office of Community and Economic Development CERTIFIED LETTER . September 24, 1987 Mr. Davi d Tanton 88329 Little Deerhorn Road Sprin9field, OR 97478 Subject: Courtesy Inspection #870697 performed at 1448 Main Street, #12, Sprin9field, Oregon 97477 On September 19, 1987, this office performed a inspection revealed the Code: at the request of your tenant, Barbara Kubacki, Courtesy Inspection at the above address. This following violations of the Springfield Housing I. Electrical Violations A. Existing ungrounded three prong (grounded type) receptacles must be grounded or replaced with two prong (ungrounded) receptacles. B. The polarity on several receptacles in the apartment is I reversed. Reverse polarity occurs when the neutral conductor is connected in error to the energized pole of the receptacle. Many electrical appliances require regular polarity at the receptacles which serve them. When an appliance which requires regular polarity at its supply is connected to a receptacle with reverse polarity the appliance may be damaged creating a potential electrical hazard. C. The ceiling light fixture in the south bedroom does not have a switch. A ceiling fixture with a pull chain with an insulated link or a wall switch controlling the existing ceiling fixture must be installed. - D. All habitable rooms must contain at least two supplied electrical convenience outlets or one such convenience outlet and one supplied light fixture. The south bedroom must have an additional .convenience outlet installed in order to meet this requi rement. II. Inadequate Comfort Heating A. The fan on the natural-gas fired room heater in the living room is inoperable and must be repaired. B. The north bedroom is not provided with a heating source. A heat source capable of maintaining a temperature of 68 degrees F. measured at a point three feet above the floor must be provided. ~'11~\,~~~~1~~~"'.u....~'llJI~~ 225 North 5th Street Springfield, Oregon 97477 503/726-3753 , . An electrical permit is required for the above repairs and must be obtained at this office no later than October 7, 1987. The above repairs must be completed no later than October 23, 1987. The City wishes to thank you in advance for your anticipated courtesy and cooperation in this matter. If you have questions regarding the noted violations or required repairs, please contact me at 726-3753. Si ncerely, ~I' B i 11 Schaub Housing Programs Specialist Copy to: David J. Puent, Building Official .. Barbara Kubacki, Tenant #1488 , ~