Loading...
HomeMy WebLinkAboutPermit Building 2002-9-12 , , . I Job# 02-01099-01 I .~ Page 1 of 2 SEP 12 2002/1:39 PM/$ 6.97 ACCT#:821-00000-215004 ..v. 'IT' 01-0010589/WILLAMETTE ROOFING J08# : 02-01099-01 CITY OF SPRINGFIELD, OREGON COMMERCIAL PERMIT City Of Springfield Community Services Division Building Safety Job Number: 02-01099-01 225 Fifth Street Springfield. OR 97477 Office: 726-3759 Inspection Line: 726-3769 Location Of Proposed Site: 1147 Main St Spr Assessors Map#: 17033541 Lot: Block: Addition: Tax Lot #: 07300 Subdivision: Owner: Bernie Hyatt 1147 Main St Phone Number: Address: Scope Of Work: Reroof City/State/Zip: Springfield. OR 97477 Repair Value: $8.275 This is a copy wilh a new Application Numberl Contractor Type General Contr Contractor Willamette Roofing and Construction 3991 Cross St, Eugene. OR 97402 Registration # 63512 Expiration Date 1/9/2004 Phone 541.688-5000 Quad Area: # Of Units: Constr. Type: Water Heater: Office Use Land Use: Zoning Code: Bedrooms: Range: # Of Buildings: Occupancy Group: Heat Source: Sq. Footage: To request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7:00 a.m, will be made the same working day, inspections requesled after 7:00 a,m, will be made the following working day. Construction Types: Occupancy Groups: # Of Buildings: # Of Bedrooms: Handicap Access? D iArea (Sq. Feet) I Main: Accessory: Required Inspections I Building - Prior to installing any roof covering, -When all required inspections have been approved and the building is complete. , . ," Jregon law reqUireS you to . ,\ \ -" '.' ",0 t d b"theOregon Utility !oIlG" rulSR adop e , I re set forti \I'J~iljcation ~en\er. Those ru he~:R 952-001- 0/\8 S32-tJO" -001 0 thro~9 rules by # Of Stories: Heighf(feet):\' ,')btain copies of the . . ~-' " , "'''1ter. (Note: thetelepho~e Current Units. Proposed Units. Ut'l'ty Notification . '.>' 'r" Jregon II Census Code: Does not apply n',; iiC)~'.:."" , :';,.~12.2344). Roofing Final Building Total: J NnTlCE~ THIS PERMIT SHALL EXPIRE IF THE WUHK AUTHORIZED UNDER THIS PERMIT IS NOT COMMENCED OR IS ABANDONED FOR ANY 180 DAY PERIOD. . . . ,,- ~ Fee Building Permil State Surcharge For Building Permit 8% Building Administralive Fee Total Building Grand Total Job# 02-01099-01 .) Page 2 of 2 r Paid On Receipt# Value/Quantity Building I 09/12/2002 10589 8,275 09/12/2002 10589 09/12/2002 10589 $99.60 $6,97 $7,97 $114.54 $114.54 Fee Amount By signature, I state and agree that I have carefully examined the compleled application and do hereby certify that all information herein is true and correcl, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon. I further state that only conlraclors and employees who are in compliance with ORS 701,055 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that Ihe project address is readable from the slreet, that the permit card is located at Ihe front of the property, and Ihe approved set of plans will remain on the site at all times durin conslruclion, ____ /1 -;/ A/~;:: 4-,. t..L ~turti . cf · - 09-/ d~O_1 )<. Date . 3, Deck: C-15/32 Incline: No Limitations Existing Roof System: A. Class A, B or C mineral or smooth surfaced asphalt telt roofing system, covered with: B. Single-ply (modified bitumen) roof system, covered with: C, Class A, B nr C asphalt organic felt or glass fiber mat shingles, covered with: Slip Sheet: A. One layer Lydall "Manniglas 1151" foil side down, mechanically fastened, B. Two layers Atlas Energy Products "FR-I 0", mechanically fastened, Membrane: "Duro-Last@"(PVC), mechanically fastened, Class A, B or C Mechanically Fastened 1. Deck: C-15/32 Incline: 2 Existing Roof S)'stem: Class A. B or C, Classification to be retained, covered with: Membrane: "Duro-Last@" (PVC), mechanically fastened, Existing roof classification remains the same. 2, Deck: C-15/32 Incline: 2 Existing Roof System: Class A, B or C BUR, smooth surface, cap sheet or gravel smfaced~ gravel must be maintained at 400 Ibs, per sq, and existing Classification will remain. Insulation: Plymouth Foam Products "Ultra-Fold lPM" or Ultra.Guard TPM", mechanically fastened. Membrane: "Duro-Last@"(PVC),mechanically fastened, UL Wind Uplift Resistance 1. Uplift Resistance: ,150 psf ' Deck: Steel, min 22 gauge Insulation: UL Classified polyisocyanurate, any thickness. Membrane: "Duro-Last@" (PVC), mechanically fastened with Duro-Last@ No, 14 steel screws and 2-inch Poly- Plates. Fasteners positioned 12-inches a.c. along fastening tabs in rows spaced 27:inches Q,C, 2, Uplift Resistance: 90 psf Deck: Steel, min 22 gauge Insulation: UL Classified polyisocyanurate, any thickness, Membrane: "Duro-Last@" (PVC), mechanically fastened with Duro-Last@ No, 14 steel screws and 2-inch Poly- Plates. Fasteners positioned 12-inches a.c. along fastening tabs in rows spaced 57.inches a.c. . . 3. Uplift Resistance: 60 psf Deck: Steel, min 22 gauge Insulation: UL Classified polyisocyanurate, any thickness, Membrane: "Duro-Last@" (PVC), mechanically fastened with Duro-Last@ No, 14 steel screws and 2-inch Poly- Plates, Fasteners positioned 18-inches Q,C. along fastening tabs in rows spaced 57-inches Q,C, REV. 11101199 . Canadian Listing ULI@ of Northbrook, IL has signed agreements with the appropriate Canadian code organizations allowing our current UL@ listings to be used in Canada under the CUL@ and ULC program, Single Ply Membrane Systems Class A - Ballasted 1. Deck: NC Maximum Incline: 1:6 Insulation: Any ULC Listed isocyanurale (tapered or uniform thickness), any thickness ULC Listed EPS insulation (tapered or uniform thickness), any thickness covered with Owens-Coming "Roof Deck Board", Membrane: "Duro-Last@"(PVC), Surfacing: River bottom stone (19 to 38 nun diam), 490 kgllO m' Single Ply Membrane Systems Class A - Mechanically Fastened 1. Deck: C-B nun Plywood Maximum Incline: 1:4 Barrier Board: Gypswn, 13 mm min, joint offset 150 rum from joints, Insulation (Optional): A. CeIotex "Star AP" or "Hy-Tec", any thickness B, Atlas Energy Products "AC Foam II", any thickness C, Owens-Coming "Roof Deck Boards", Membrane: "Duro-Last@"(PVC), 2, Deck: NC Maximum Incline: 1:4 Insulation (Optional): A. Celotex "Star'AP" any thickness. B, Atlas Energy Products "AC Foam II", any tliickness C, Owens-Coming "Roof Deck Boards", Membrane: "Duro-Last@" (PVC), 3. Deck: NC Unlimited Incline Membrane: "Duro-Last@" (PVC) 4. Deck: NC Maximum Incline: 1:4 Insulation: Celotex "Star AP", any thickness mechanically fastened or adhered. Membrane: "Duro-Last@"(PVC), 5, Deck: C-B nun Plywood Unlimited Incline Insulation: Any ULC Classified EPS insulation (tapered or inform thickness) or polyisocyanurate. any thickness, mechanically fastened. Barrier Board: Gypsum, 13 mrn, mechanically fastened. Membrane: "Duro-Last@"(PVC),mechanically fastened, 6, Deck: NC Maximum Incline: 1:12 Insulation: Atlas Energy Products "AC Foam II", 25 nun min. Membrane: "Duro-Last@" (PVC), 7. Deck: NC Maximum Incline: 1:6 Insulation: NRG Barriers "E'NRG'Y 25 nun, any thickness, mechanically fastened. Membrane: "Duro-Last@"(PVC) UL-7 UL & ULe Nov 99.doc