HomeMy WebLinkAboutOccupancy Correspondence 1983-3-21 .. . SPRINGFIELD ,CITY OF SPRINGFIELD 'Pepartment of Public Works ' . . , . .'..t " " Ma rch 21, 1983 ,. '.. .' .- " ....,. " Mr. Dale Seese 241 West K Street , Spri ngfi el d, Oregon , 97477 ..~ /, ?.../ RE: Occupancy Inspection at 1072 Main Street, Springfield, Oregon ',\., ',- Dear Mr. Seese. At your request the Building Division of the City of Springfield conducted an Occupancy Inspection of the building located at 1072 t1ain Street, Springfield, Oregon. ,The pro- posed use of the building as 'apartments will cate~orize .its usage as a R-1 Occupancy. The following items include but 'are not limited to a complete list of items that shall be installed, repaired, or replaced in order to confonn to' all applicable codes for that occupancy. STATE STRUCTURAL SPECIALTY CODE AND FIRE AND LIFE SAFETY CODE Is.s.C.) 1. An attic partition dividing the attic area into horizontal areas not exceeding 3000 square feet shall be installed. The partition shall extend from the ceiling to the roof and be constructed of not less than ~" gypsum wal1baord, I" tight-fitting wood, 3/8" plYWOOd, or any approved noncombustible material that is a'dequately sup- ported. S.S.C. 3205 (b) " 2. Adequate lintel suppport shall be provided for the doorways that are to be cut into the existing masonry wall. S.S.C. 2420 3. A wired-in type smoke detector shall be installed in each rental unit~,==S;S.C:_I210 and Springfield City Code 7-5-6 OREGON ELECTRICAL SPECIALTY SAFETY CODE IE.S.S.C.) 1) The change of use from a motel to apartments will require an increase in the main service to meet the demand of additional range/oven ciruits, small applicance cir- cuits and lighting circuits. All wiring shall be installed in accordance with the Oregon Electrical Specialty Safety Code Standards. E.S.S.C. 110-8 OREGON STATE PLUMBING SPECIALTY CODE IP.S.C.) 1) A single control valve shall be installed on 'the water supply line ahead of the water meter. P.S.C. 1401 2) The roof drainage water shall be channeled into approved storm water drainage pipe and discharged into the front catch basin. P.S.C. 1401 225 North 5th Street · Springfield, Oregon 97477 . 503/726-3753 .... . . . Mr. Dale Seese Occupancy Inspection '1072 Main Street' March 21, 1983 Page 2. '.", "All necessary permits shall be obtained and required inspections conducted befor.e a Certificate of Compliance will be issued. Please direct all inquiries to the SpringfieId Building Division at 726-3753. /' SincereIy, ' ~Qj-~ orr-uv ~. David J. Puent :,~. Building Inspector , DJP/Ih