HomeMy WebLinkAboutSpecial Inspection Occupancy 1983-9-30
,
-
SPRINGFIELD
CITY OF SPRINGFIELD
Department of Public Works
September 30, 1983
"
.'
/,
CERTIFIED LETTER '/
Mr. Dale R. Seese
:241 West'K Street
Springfield, Oregon 97477
RE:Occupancy Inspection at 1072 Main Street, Springfield,
, Oregon
.~...
Dear Mr. Seese:
',At your request the Springfield Building Division conducted an
q" Occupancy Inspection at the above referenced address.
;' ,~he proposed use of the lower portion ~f the building as an
assembly area with a potential occupant load of more than 50
people will categorize its usage as an A-3 Occupancy.
The following items shall be installed, replaced or repaired in
order to conform to the applicable code standards for that
occupancy.
...'
,STRUCTURAL SPECIALTY CODE AND FIRE AND LIFE SAFETY CODE (S. S. C. )
1. A minimum of two exit doors are required where the potential
occupant load exceeds 50 people. Exit doorways shall be of a
size as to permit' the installation of a door not'less than 3
feet in width and not less than 6 feet 8 inches in height.
The doors shall be capable of opening so that the clear width
of the exit is not less than 32 inches. S.S.C. 3304 (el
? All exit doors shall swing in the direction of exit travel
and be provided with panic hardware except for a main exit
door. A key locking device may be used in place of panic
hardware, provided there is a readily visible sign adjacent
to the doorway stating THIS DOOR MUST REMAIN UNLOCKED DURING
BUSINESS HOURS.S.S.C. 3318
3. Door openings within the required rated exit corridor shall
be protected by a door assembly having a fire-protection
rating of not less than 20 minutes, and be self-closing.
S.S.C. 3305
4. The enclosed usable space under the stairway shall have the
walls and soffits protected on the enclosed side with 5/8"
type X wallboard. S.S.C. 3306,
225 North 5th Street . Springfield, Oregon 97477 · 503/726-3753
.~
-
r
-
Mr. Dale Seese
Occupancy Inspection
1072 Main Street
September 30, 1938
Page 2.
5. Handrails shall be provided for both stairways. They shall
be not less than 30 inches nor more than 34" above the nosing
of the treads, and extend not less than 6 inches beyond the
top and bottom risers. S.S.C. 3306
~
/
6. The glass panels adjacent to the doorway, located witin 12
inches of the door, shall be of safety glazing materials.
S.S.C. 5406
, .
7. Walls within water closet compartments shall be finished with
a smooth, hard, nonabsorbent surface to a minimum height of
4 feet above the bathroom floor.' S.S.C. 510
'8. The openable window area for natural ventilation shall be,not
less than one twentieth of the total assembly room floor
area. S.S.C. 605
9. The ceiling and wall coverings in the upstairs area that have
been damaged from water contact shall be repaired. S.S.C.
2516 If)
ELECTRICAL SPECIALTY SAFETY CODE (E.S.S.C.)
1. The buildings original electrical wiring intallation is
approved for the A-3 Occupancy. All additional wiring, such
as outlets for the washer, dryer and additional receptacle
outlets shall be removed or rewired in accordance with
applicable Code standards. E.S.S.C. 110-8
2. The electrical equipment located in grounded areas such as
the kitchen, utility room and bathrooms shall be properly
bonded. E.S.S.C. 250-42 .
3. Receptacle and switch cover plates shall be installed on all
outlet boxes. E.S.S.C. 370-15
STATE PLUMBING SPECIALTY CODE CP.S.C.)
1. The downstairs bathroom that was locked at the time of
inspection shall be completed. Water closet bowls for public
use shall be elongated bowls equipped with open front seats.
P.S.C. 901
>
"
~
-
Mr. Dale Seese
Occupancy Inspection
1072 Main Street
September 30, 1938
Page 3.
The above items are requirements only for the existing building.
'Other items such as parking, alley improvements, sidewalks, storm
drainage, exterior lighting, etc., that have been required as
part of the Conditional Use Permit or might be required as part
of Development Coordination Board review, have not been addressed
in this repor t.
Please direct all inquiries to the Springfield Building Division
at 726-3753.
Sincerely,
David J. Puent
Building Inspector/Plans E~aminer
DP/lh
/
f
.'
. ..
~ . SENIit:.R.:
~
~
Complete items I, 2, lUld 3.
Acid yaw adJress ill tlu: "R.ETIJRN TO" Ip-=e on
reverse.
:-
~ 1. The following service 1'1 requested (check one.)
nXhow to whom and d::lte deUVered............_4
o Show to whom, date and addreu of de.live.ry... _ lit
o RESTRICTED DEUVERY
Show to whom and date deUvered............_4
o RESTRICTED DEUVERY,
Show to whom, date, and ad~ress of delivery.$_
~
?
=
~
(CONSULT POSTMASTER FOR FEES)
z. ARTICLE ADDRESSEO TO:
'0"
U
z
"
'"
'"
..
~
..
...
!!
Mr. Dale Seese
241 West K Street
Springfield. Oreqon
3. AiitTtCLE.DESCRIPT10N:
REGISTERED NO. "I .CERTlFIED NO,'
, 329960200
IAlway. obtain sign.eture of addressee or .gen1l
97477
INSURED NO.
~ I hove receIved L'''l.c article described above.
~ SIGNATURE DAddressee OAuthorir.cd apt
i \ ~'Z f;"J..P.'1.a- ~
~ / Ih(TE Of DEUVr;.RV A' R~",
~ /0 L...93 {Ji ':0;=1 g ~ ~
~ 6. AODRESS (C~ on'" 1f....-.\1 ~ 23 ~ -i ~ J
n ,~"
~ '- .Un 1\~'9
in 8. UNABLE TO DELIVER BECAUSE: -C\:ERK"S
o INITIALS
~
;:. ~
'trOPO : 1979-288-348
I
I
I
UNITED STATES POSTAL SERVICE
:OFFICIAL BUSINESS
SENDER INSTRUCTIONS
Print your nam..l.tdress. end ZIP Cod. in the spact below.
. Complete Ibm. 1, 2. end 3 on the r8V1~
. Anatb to front of article if rpac. pmnltJ,
otherWise effix to back of ,nlcle.
. End.... artld. "R"'m Roceip. R,quoae:- f 1 Y
Idlecantto number.
PENALTY FOR PRIVATE
USE TO AVOID PAYMENT
OF POSTAGE. ~
..:..
+~~
U.5.:MAIL I
.
,
RETURN
TO
OF SPRINGFIELD
UC:PARTMENT ,OF PUBLIC WORKS
225 NORTH 5th STREET
SPRINGFIELD, OREGON 97477
(Name ofSerider)
'"
(StIeet or P.O. Ila><)
(Oty, State, and llP Code)
;