Loading...
HomeMy WebLinkAboutPermit Building 1983-6-20 (2) ,.~~ f;j,,~. . f:,\, :::-'~V.".".l~,t.>-'" .;- .. . ui r~d ^ ~,', " . ):"i'ff~~p~'c te, s .. " IT IS THE RESPONSIBILITY OF TilE PER!llT HOLDER TO SEE THAT ALL INSPECTIONS ARE MADE AT THE PROPER TUlE, THAT EACIl ADDRESS IS READABLE FROlI TIlE STREET, AND THAT THE PERHIT CARD IS LOCATED AT TIlE FRONT OF THE PROPERTY, BUILDING DIVISION APPROVED PLANS MUST BE ON JOB SITE AT ALL TIllES, PROCEDURE FOR REQUESTINr, INSPECTIONS, Call 726-3769 (recorder) state you CITY DESIGNATED JOB NUMBER, job address I type of inspection requested ,>.'and \'lhen you will be~ reedy for the inspection. Contractors or o\mers name and phone n~~ber. Requests received before 7:00 am,will be ~~de the same day, requests received after 7:00 am will be ~de the followin~ work day. Your City Designated Job Number Is, B '1/ 702 Job Address, ~~ MAl/AI ~ -=E7'" ~XE.I ~: 0AJlJY P~B~A" Phone:,72~.t::)~S.::c Contracto":~N_'; &.N.D~ tC:e> ~c.,NS Phone, * o IXI FOOTINGS & FOUNDATIONS: To bcrnade . '.after 'trenches -arc "excavated and forms are erected. all steel in p~~~t _priOr~~~ngconcrete. f\7l lNDERGROii€:"" P~rnbing. ,Electrical. ~ Gas. Sanitary Sewer, Storm Sewer, 0 Water and Drainage lines. To be made priort~cover~nB or fill ing ,. trenches, /,..-IN.,. ,~ O UNDERFLOOR:, Plumbing, Electrical, Mechanical. To be made prior to installation of floor ins~lation, decking or floor sheathing. IX I POST 6 BEAM: To be made prior to installation of floor insulation, de~Lnll Jf,/~o~,r 's~~~i: O FLOOR '(NSULATION F, VAPOR BARRIERS, To be made prior to instal12tion of decking or floor sheating. o o D D SYTE INSPECTION: To be ,made after excavation. but prior to setup of forms. UNDERSLAB PLm1BING, ELECTRICAL & ~lECHANICAL: To be made before .any work is covered. CONCRETE SLAB INSPECTIO~: To be made after all ins lab building service equipment, conduit, piping, accessories and other ancillary equipment items are in place but ..before any concrete is.poured. ~~SONRY: Steel location, bond beams grouting or verticals in accordance with U.B.C. Section 2415. o [l] ROOF SHEATHI~G k~D NAILING: to installing any roofing. Prior ROUGH PLUMBING, ELECTRICAL F, MECHANCI^L: No ~ork is to be co\'ered until these inspections have been made and approved. ~ FINAL'PLUMBING 1)<: I FINAL ELECTRICAL o FINAL MECHANICAL o FINAL FIRE DEPARTMENT J~ o o o INSULATION F, VAPOR BARRIER: 'To be made after all insulation and required vapor barriers are in place but before any lath or gypsum board inJ~~,;;~cOvering is applied. FRA}lINGr: To be made after the roof, all framing, fire blocking and bracing are in place and all pipes, -chimneys'~nd'\'ents -aTe complete 'and the rough electrical, plumbing and heating _wires. pipes and ducts aTe appro\'ed. FIRE 6 SEPARATION I~ALL: Located & '---, constructed according to plans. ~ LATH AND/OR GYPSUM BOARD INSPECTION: ~ To be made after all lathing and ~ g)~sum board, interior and exterior, is in place but before any plasterill8 ---, GLU-LAM BEN-IS: Inspection Certificate, ~s.applied or before gypsum board ---3 by an approved agency, furnished to Jo~nts and fasteners are taped and the City's Building Division before 'finished, IF A-#Y 'beams are placed, '(2501-U,B,C,"STOS, WOODSTOVES: After installation is 25-10,11). completed. . ~ SIDEWALK & DRIVEWAY: Required for all concrete paving within street right-of-way, to be made after all excavating complete & form work & sub-base material in place. CURB AND APPROACH APRON: After forms are erected but prior to pouring concrete. D o ATTIC DRAFT STOPS & CURTAIN WALLS. FIREPLACE: Prior to placing facing materials and before framing inspection. SPECIAL INSPECTIONS: In accordance with Section 306 of the Building Code a special inspector shall be employed by the O\\~erl Contractor during construction of the following work. A cqpy of the special testing reports -shall be furnished to the Building Division. =:J =:J =:J STRUCTURAL 'CO~CRETE: In excess of 3000 P,S,I. (306 a,I) D PARKING LOT: After gravel place but prior to placing or concrete. is in asphalt STRUCTUR~L WELDS: Preformed on the job, (2722 f) HIGH STRENGTH BOLTINQ.: During all bolt installation and tighting operations (306 a.5) .' SPRAYED ON FIREPROOFING: Standards 43~8) SPECIAL GRAOING, FILLING: ~Jring & Chapter 29) .(U,B:C, EXCAVATION AND earth~ork. (306 a.ll *In addition to the inspections specified hereon, the B~ilding Official may make or require other inspections of any construction work to ascertain compliance with the Building, City or Zoning Codes. o CITY'S SITE rLA~ REVIEW BOARD INSPECTION: Must be requested 2 days in advance of the date you wish inspectio~. All project conditions such as landscaping. parkin& lot striping etc. must be com~leted hefore re~uesting this inspection. lXJ FINAL BU!I.DING: Must he requested after the final Plumbing, Electrical. ?-Iechanical and Fire Department inspections are m~de ~nd approved. No Occupancy of the premises can be made until a Certificate of Occupancy has been issued by the Building Division ar.d posted on the premises SICNAY~~ jj _u d .0 OATE c: /,.? n /~-. r / * Al.L MANHOLES AND CLEANOUTS MUST BE .\CCESSIBLE, AIlJUSTMENT TO BE MADE AT NO COST TO: ruE CIn'.