HomeMy WebLinkAboutSpecial Inspection Occupancy 1988-2-1 .-" '''" M()... - - <:' .. CITY OF SPRINGFIELD Office of Community & Economic Development Planning and Development Department CERTIFIED LETTER . February I, 1988 . \':. .... ", ::;~':. ;~~:;:;?~/i.';:\,'i' Jack Heacock 6893 Main Street Springfield, OR 97478 -.k Subject: Occupancy Inspection at'22ll Main Street Springfield, ~..~. * 1..... " P._.._~ed Use: Sheet Metal Shop City Job #880011 At your request, the Springfield Building Safety Division recently conducted an inspection of..the building(s) at the above address, The purpose of the inspection was to determine the suitability of the. building(s) for the proposed use as indicated. Based on the proposed occupancy, the existing conditions which are mentioned below do not meet the minimum Building Safety Code requirements. C_..~_tive measures must be taken prior to occupancy to install, repair, replace or modify the following items in order for the building to conform to applicable safety codes: Structural 1. Exit doors requiring a key or special knowledge or ~!L. ~ to open from the . inside shall be provided with a sign stating "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" in one inch high letters on a contrasting background. Electrical I. 2. The electrical service panel contains unused openings in its protective face plate which must be closed with circuit breakers or blank fillers, 3. Romex wiring shall be removed or protected up to a height of eight feet. 4. Secure electrical conduit within three feet of every termination box and fitting. .!:. . .' 225 Fifth Street . Springfield, OR 97477 '. .503/726-3753 ,... . ~.. ..",' " Jack Heacock February I, 1988 Page 2 ~ - 5. In areas where combustible paneling has been added to the walls the electrical boxes shall be brought to within 1/8" of the finished surface of the wall or extension rings shall be used. 6. Light fixtures shall be adequately secured to the ceiling. ',' 7. The electrical system shall be checked for proper grounding after it is energized. Plumbing }' , ,. 8, Install open front seats on all toilets when they are in a public restroom. , 9, Install an exhaust fan in the toilet room capable of providing a complete air change every 15 minutes. 10. Install an atmospheric vacuum breaker on the laundry tray faucet. A permit shall be obtained prior to installing the exhaust fan. A licensed electrical contractor is required for all new work and substantial alterations to existing structures which are for sale, lease or rent". However, work on alterations to and repla_~~..t of parts for electrical devices which is necessary for maintenance of existing electrical installations may be done by the owner of the property. Please also note that the above items which effect 'the health and safety of the occupants must be corrected and verified by the appropriate City inspectors prior to using the building for the proposed purpose, If we can be of assistance in clarifying the requirements, or the options available to bring the building into compliance, please call us at 726-3759. Sincerely, k7'l~ Don Moore Structural Inspector )J~_C1J-o Electrical Inspector ~~t~ Plumb./Mech. Inspector' CC: Dave Puent, Building Official , . .' , ./...;. .....:.