HomeMy WebLinkAboutSpecial Inspection Correspondence 1990-12-19 . . Civil . Structural-Architectural . Fire Protection P.O. 80X 139 . 474 WILLAMETTE STREET Code Consultant. Plan Checking. Construction Inspection EUGENE, OREGON 97440 . (S03) 484-9080 Attention: John Almenherst Spectra Systems 587 Shelly sprinqfield, OR 97477 December 19, 1990 RE: 1999 Main St.. SDrinafield - ~tructural Damaae As you requested, I have made an inspection of this building to determine the extent of damage due to vehicle impact at the southeast corner adjacent to the street and alley. I also have discussed with you and received information with regard to the proposed methods of repair by your firm and the masonry sub-contractor. Based on my observation and the information received, it is my conclusion that your proposed repair methods will correct the structural damage due to the vehicle impact. These repairs methods are as follows: a. The existing roof construction and damaged portion of the wall have been temporarily shored up with timber shoring. This shoring appears to be adequate. b. The damaged portions of the concrete block south and east walls should be removed. This would include removal of the concrete block along the east wall from the southeast corner to the door opening and along the south wall from approximately two feet from the southeast corner on a stepped diagonal at each course, which is approximately 45 degrees to the top of the wall. c. There is an existing 16" deep concrete beam in the 8" concrete block wall at the east wall which is to remain and be shored during the removal and re-supported by the new concrete block wall. d. The block walls in the removed areas are to be replaced with eight inch standard concrete block units. The concrete block is to be reinforced with a bond beam at maximum four ft. intervals and at the top of the new construction. Bond beams shall that contain two #4 reinforcing bars. Vertical reinforcing to be #4 at fpur ft. maximum spacing, three #4's at the corner and one at the side of the door opening. Reinforced voids are to be grouted as .well as complete groutinq of the south wall from the stepped courses into the . 2 . portion of the wall remaining so that this is a solid grouted section of wall. e. The masonry construction is to be in, accordance with applicable code requirements. I hope you find this report adequate for your purposes at this time. Please contact me if you have further questions. Thank you for this opportunity to be of service. Very truly yours, Emile Mortier, P.E. ECM/rc