HomeMy WebLinkAboutSpecial Inspection Correspondence 1977-4-7 -.-," ,.~, :.:. ;-- . ""'-, . " ," .;,~ CITY OF SPRINGFIELD SPRINGFIELD. OREGON 97477 DEPARTMENT OF PUBLIC WORKS April 7, 1977 34" MAIN STREET 747.4221 * Mr. Charles Lynch 420 West 13th Avenue Eugene, Oregon Dear Mr. Lynch, An inspection was made by the Building Department of the City of Springfield on March 30, 1977, at the building located at 1710 Main Street, Springfield, Oregon. It is our understanding that this property is owned by Mr. Charles Larson and that your firm manages the property, This building is located in Fire Zone II, The first floor of the structure is an F-2 occupancy, the second story is an H Occupancy. The following items must be done for this building to conform to the minimum standards of the Uniform Building Code as adopted by the City of Springfield. 1. The existing beams in the center of the building that support the second story are inadequate and are failing. They consist of two 6" x 14" spaced l~" apart and span 29 feet on one side of the building and 26 feet on the other, The joists appear to be 3" x 10", 24" on center spanning 24' on one side of the building and 20' on the other, being supported by the 6" x 14" beams in the center and on block walls on the exterior, There is several inches of deflection in the 6" x 14" beams and evidence that the beams are pulling loose from their connection point at the stairwell. The minimum size of beams required to support this area would be 2 - 8" x 24". 2. All walls and ceilings in the first floor shall be returned to their original fire resistive condition. 3. The walls and ceilings in the restroom to the rear of the building that is under the deck that provides exit facilities for the units upstairs shall be of l-hour construction. 4. The stairs at the rear of the building shall be made to conform with Section 3305 of the U,B,C, 5. The restroom facilities shall be provided with an exterior window at least 3 square feet in area, freely openable, or a mechanically operated exhaust system, which is connected to the light switch, capable of providing a complete change/of air every 15 minutes. Such system shall be vented to the outside air and at the point of discharge shall be at least 5 feet from any openable window. (Section 1105, U.B.C.) . . Mr, Charles Lynch April 7, 1977 Page 2 / 6, The neuaral bar from the service disconnect shall be bonded to the cold water pipe with a No.6 bore copper wire and attachement will be made with an approved ground clamp. 7. All wiring shall be in a raceway. 8. All junction boxes shall have approved covers. All necessary permits must be obtained before work begins and all work shall be accomplished according to applicable codes and inspected before a Certificate of Compliance will be issued, Should you need further information please feel free to contact the Springfield Building Department at 726-3753, Sincerely, ~~ Dan Smith ~ Building Inspector DS:sm