Loading...
HomeMy WebLinkAboutPermit Signage 1983-3-23 .'.. ~ . , I i . ~ ~ , I , {.t ;;-.~.: ...,. ,," .~, ,. ,,~ ". ~~ .......... ., .- J ~ - '-'I .,~ i !.:: . . "- -.' ..~ ,,~I, . I I e SPRINCFIELD ,......,..", ",,11 IN FOR.MATION: 726-3753 .. , city of springfield 225 n. 5th street INSPECTIONS: 726-3769 SIGN PERMIT APPLICATION A. LOCATION OF SIGa (ADDRESS) LEGAL DESCRIPTION / 7 OWNER OR PROPERTY ADDRESS 35-77 o~.3I_gl ,i::b/;;jt/ -1":" ;;;AA.;;.,~.>.; .:??,S 4( :.;'3 ot.,' ZIP /';)Q/" TA.'i: LOT 7!' C:, t;, Q~ ,7'<':;'71'77 PHONE <;77 Y 77 ~'.fi S/;v .Y OWNER) OllNER OF SIG:l (IF OTIlER THMI PROPERTY ADDRESS PHONE A'1t/~....;I,.... TYPE OF .BUSWE5S /k.,'/ /..4 ,)P~J NAME or BUSIUESS, HR.'!. ETC. ~"";tIJ B. TYPE OF \lORK: VERECT _ALTER _RELOCATE _OTHER C. STRUCTURAL TYPE 'or SIGN:. _HALL .,0REE5TANDIllG _ROOF _PROJECTING _HARqUEE _UNDER l~qUEE _OTF.ER [). USE AlID CEA.~CTER or SIGN: ~Iri' INCIDENTAL ~~LE FACE _SINGLE FACE ~ "':"-~TI-FACE . .; . _READER BOARD _BILLBOARD / "',', E. VENDORS, CONTRACTORS: "'" "ICk:1 . SIGN ERECTOR 1";iI-/{/'Vc;,, rllcm: ./.DD:'.ESS CITY LICENSE IlIP.1BER 1'1 -' / A . I . SIGN HANUFACTURER (IF OTHER THAN ERECTOR) ADDP.ESS .~Ir EX? DAn: .P!!ONE F. On1E1lSIONS, nISTALLATION 6< CONSTRUCTION I" .; TOTAL HEIGHT ABOVE GRADE . VERTICAL DIMENSION OF SIGN J' HORIZONTAL \lIOTIl OF SIGN (. , DnlENS ION FROM GRADE TO BOTIOM OF SIGN G. EXISTING SIGNS ARE THERE ANY EXi:ST!!TC ~IGNfi? _n:s' '1.--llO !nn1B~. SIZE IN SO.FTG. 1 TIlIC1WESS OR DEPm If' 8" ALL EXISTING SIGNS FOR BUSINESS, ETC. . DOES SIGN PROJECT BEYOlID PROPERTY LIlIE? _YES vNo IF YES, DIllENSION BEYOND PROPERTY LINE NOTE: IF PROJECTIOn IS IIORE THAN 12" OVER PUBLIC PROPERTY TI!E SIGN ERECTOR I.nJST FILE \lITH TIlE nUILDI:IG DIVISION COPIES OF HIS/IW,R LIABILITY AND PROP- ERTY DA.'IAGE mSURANCE POLl:IES. I. DESCRIBE TYPE OR l'ATERIALS SIGN IS CONSTRUCTED OF. . ;%.../.;.> /.,.-<' e . - ~/ ../ {0,,{...~:>,../ ..14.../ ;,4'/4/ fi,:-" r H . /."re..~' "'.".... . HIll SIGlI HAVE ELECTRICAL IJIR!!lG? .,jJfIIp . ; IF YES. \/HIe!! APPLY? EL~CTltlCAL SIGll _IlllJ!1I.c'lATED (IlIDIP.EcfI:'l LIGI!TED) ELECTRICAL COllTRACTOIl ADDRESS LISC.NUMBER pr.om: J'SITE INFOPMATIOtl (LAIlD USE) -- EXISTING USE or BUILDIlIG OR LAND (~R LAST USE IF .VAC)u~T) t:lHc/ dd kI _INDOOR Bt!SINESS ...cUTDOO:1. !<ERCllAlIOISIllG n PROPOSED t!SE OF BUILD!NG OR LA.~D: ~ 4' ht., K. VALUE OF SIG:l; J CJcJ ,:! L · . I H . [AVE CAREFULLY E.."{.A!>IINED the completed application for cermit and do hereby certify thac all 1nfo~ation is true and correct, and I further certify that all work performed shall be done in .cc?rd~~ce With the Springfield Sign Ordinance. the Unifo~ Sign Code as adopted by the City of ~or_n~t~eld and a1: ocher Ordinances of the City of Sorin~field and the laws of the State of wre~Qn ~ertainin~ to t~e worl~ described n~.~~n. I further certify tha~ mv ~:~~ Co~t~actor Li- 8~~~:(~Jith the City of Spri~gfield is 1n full force and effect as' required by Sprin~field Codes P -1 ) and 9-7-20(2). I will request all required sign insDections listed on the approved t1r':: t. lIA.'if: (PLEASE PRIlrr) 4;l/l~r ~ 44-~'.>.r StC:IAT1JRE ~:;;..- o~ .OATE _;--?;-J'j . lI,. , ..~ . e PLEASE READ 1) Seoarace St~ Aoolicacion: 10 tne..._~lgn (;oae.- Electrical: Any permit issued under this application will includ! wiring ~n or on sign structure, the SUPpLY wires for connection muse be covered on an electrical permit. Electrical connection must be made only by a State Licensed Electrical Contractor. Illuminated signs (both Intern~lly and externally) must conforon to Sections 9-7-4 (4) & (5) and 9-7-18 of the Springfield Sign Or- dinance. A separate application is requirad for aach separate sign.as dafined 2) 3) Plans Reouired: This application is to be submitted with two complete sets of plans showing di- menSlons and neight of sign; advertising message on sign: location of sign on property with di. .mensions to properey lines, structural decails of support framing. bracing and footings; ~aterla19 of construction for sign and sign struceure; electrical equipment and lighting; size and location of existing signs on property for the same buslenss, all as required to determin~ co~liance with the Springfield Sign Ordinance (Articla 7 of tho Springfield City Code). Also,. show the follow-. . . ing information..on eIle plot plan (plan showingpropart:y. lines. and location of .signs) :.. a) b) 4) Show the location of all. existing sign(a) as 'well as: proposed sign(s).' Show tho length of the straet frontage taken up by the busi~ess or building. For wall signs. show the length of the building frontage. . c) Show the location of entrances.open to the public and driveways. When requi:ed, because of design, size, etc. f engineered drawings and calculations must be pre- pared by a licensed enginear or shall conform to design standards on file at eIle Building Divi- sion Office. Plans of insufficient clarity or detail will be returnad to tho applicant with nO'permit being issued. - Signs must meet corner vision clearance requirements as described in Figure 9 of the Springfield Comprehensive-Zoning Code. NOTE: No sign may be arected which is less than 12 feat horizontally or vertically from' overhead electrical conductors in excess of 750 voles, or less than 5 feet in any direction froc overhead electrical lines which are energized at less than 750 voles. If a sign is not installed within 60 days after tha date of issue of eIlis permit. the parmit be void.. '5) 6) 7) 8) 9) Ins'Deccions: shall /. ./ a) Sice Ins'Deccion - to be made before the sign is placed. Usually, the" FoocinE Insoection (it applicable) ~~y be made at the same time as the Sice Inspection. lbe rooting Lnspec- tion is to be made after hole(s) 1s aACav~t~ci, but prior to the placement of c~ncrete. b) Final Insoection,- to be mada upon completion of all work. c) ~lectrical - all electrical signs must be inspectad for alactrical hook up aftar tha sign ls erectea and before the sign is turned on. . .~ I i CALL FOR THE REQUIRED INSPECTIONS ON THE 24 HOUR INSPECTION LINE AT 726-3769 FOR OFF1~~ U,~ ONL~ SIGN DISTRICT 1". () H 't. ZONE DISTRICT C. c- TOTAL SQUARE FOOTAGE OF SIGN / l!! Lft REOUIRED INSPECTIONS: ~ . _SITE/LOCATIO:l ..aOOTING OR MEl'HOD OF ATTACHMENT JOB q. ~~\lnq3 i i I , i SIGN PERMIT FEE: 1s:tJcJ .-{}. . ; i , ELECTRICAL PE~~IT FEE: _ELECTRICAL _OrnER ~iNAL 4~ STATE SURClIAR.GE: TOTAL: ..0- f/?:OO DATE l.., - 2 5 ~x 2. RECEIPT 6 (" 1/ 77 gQ --- ' r U SPECIAL CONDITIONS TO BE SATISFIED BEFORE ERECTION OF SIGN: - IS ~ _ __~ _ P~Pe7<!..,'r' '-uVe:: '-C.>'Ch, c::.~ : ~;(/GEi? D,zL)T PL.#-N- AI't-'I!!.t)J(. '7' BcffiN.t:> FAcE"(J':ff~a.1 r' . ~/6',MH(J6rT3G: 1...()t:4r8P k.JH l-'. . ~N ?If!./t/AT€ PI€.t:JPG1<!,t,-', ADDITIONAL INFO~~~TICN NEEDED BEFORE PERMIT ~y BE ISSu~D: CLERK SECTION: pa~~ j/ 9- 7.- '7 ...... DATE h~3-f~ APPROVED BY: SPRINGFIELD SICN ORDINANCE , , .""'''.Ij,,~