Loading...
HomeMy WebLinkAboutOccupancy Correspondence 1994-1-24 ~ ., v '- . .- . " J~.' 225 FlFT/-{ SiliEff SPRINGFIELD. OR 97477 (503) 726-3753 FAX (503) 726-3689 DEVELOPMENT SERVICES DEPARTMENT CERll1'lliD LETTER January 24, 1994 Romania Chevrolet *, John Martin 2020 Franklin Blvd. Eugene, OR 97403 Subject: Occupancy Inspection at 3445 Main Street, Springfield, Oregon. Proposed Use: Auto Body Shop Dear Mr. Martin: At your request, the Conununity Services Division/Building Safety conducted an inspection of the building at the above address. The purpose of the inspection was to determine the suitability of the building fOl' the proposed use as indicated. Based on the proposed occupancy, the existing conditions which are mentioned below do not meet the minimum Building Safety Code requirements. Corrective measures must be taken prior to occupancy to install, repair, replace or modify the following items in order for the building to confoml to applicable safety codes: r,w4 ~ Structural and Fire and Life Safety 1. Provide an approved spray booth fOl' all painting operations. 2. Provide a fom'-inch high liquid-tight containment curb arouud the iute.-io," of the paiut storage room. 3. The dOOl" pl"oviding eg'"css f,'om thc paint storagc '"00111 shall opcn out in the dircction of cxit travcl. Thc dOOl" must bc sclf-closing and be fittcd with panic hardwarc. ) ., '~........; . Romania Chevrolet Occupancy Inspection Page 2 4. Provide an approved fire extinguishing system for the new paint spray booth and the paint storage room. The same system may serve both areas if it is of adequate capacity. Coordinate l"equirements with the City Fire Marshal. 5. Provide approved mechanical exhaust ventilation sufficient to prevent the accumulation of flammable vapors in the paint storage room. The intake for the exhaust system must be located within six inches of the floor. 6. Provide a fire extinguisher with a 2-A, 10 B:C rating for each 3,000 square feet of building area. The maximum distance to an extinguisher from any location in the building shall not exceed 75 feet. Building permits must be obtained for the above items which involve repairs or modifications to the structural, electrical, plumbing or mechanical systems of the building and for any additions or revisions you wish to make to the building. The above items are requirements for the existing structure only. Other items such as parking, paving, site improvements, sidewalks, etc., have not been addressed as part of this inspection, and may be required. Please contact the Planning Division of this office regarding any necessary improvements to the site. Please note that installation or repair of electrical systems on property which is intended for lease, sale or rent must be done by an electrical contractor who is licensed by the State of Oregon. If you need any further information or have any questions regarding the above requirements, please contact me by phone at 726-3623. Sincerely, ~9?~ Don Moore Construction Repl"esentative "... - cc: Dave Puent, Community Services Manager Dennis Shew, Fire Marshal Amacher & Company 1600 Executive Pal"kway, Suite 200 Eugene, OR 97401