HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 1989-4-24
".~~.'---"":-"~r'. ., . ......,....--..._~~;'"
....-.....-......--...-.--,-=.....,.....- -
NORTHWES't'rESTING LABOR_rORIES, INC.
2285 Nugget Way
Eugene, Oregon 97403
"Phone: (503) 746-9649
Laboratory Number
E-47799
WEEKLY INSPECTION REPORT
Date April 24, 1989
Job:
Kapco Warehouse
Inspection of:
High Strength Eol ts
Fabricator or Erector: MBSI
Addres 5:
3400 Main Street
Springfield, Oregon
Contractor: Bineham Construction Canpany
Shop
Field
xx
Date 04-21-89
Hours 3 . 0
Miles 20
Inspector M. Meyer
S-487
Performed inspection on the 3/4" and I" A-325 high strength bolts in
the beam to beam and beam to COlUIlU1 connections. The 3/4" bolts were
checked with a calibrated Uttica torque wrench, in accordance with the
AISC Manual, and are tightened to the suggested torque values, The 1"
bolts were installed with load indicating washers, The washers were
checked in accordance with the manufacturer's recrnrnendations and in-
dicate the bolts have been p~vt=rly tensioned.
Dale
Hours
Miles
Inspector
Date
Hours
Miles
Inspector
Date
Hours
Miles
Inspector
.~
Date
Hours
Miles
Inspector
-
Reponed to:
Bineham Construction Company
NORTHWEST TESTING LABORATORIES
J11' :!~bger
Eugene Office
-.