HomeMy WebLinkAboutPermit Field Test & Inspection Report 2009-7-28
..._----
lrfa ~;z Infonnation
,.,~. .To Build On
Engineering. Consulting . Testing
t9- C031S
~
DAILY FIELD REPORT
Date Performed:
July 28, 2009
Hayden Homes
2464 SW Giacier Piace Suite .110
Redmond, OR 97756
Report Number:
722-90076-7
Client:
Project Name:-
Mt Gate Cottages
Mountain Gate Drive
Springfield, Oregon _
5Y5 \.At. 0tcrle--1!::1o
Project Location:
PO No.:
Type of Inspection:
Soils Observation
Weather:
Clear
Field Observations and Comments
AM: As requested, a representative of PSI was onsite to observe and document earthwork operations for the Mountain
Gate Cottages. The contractor was placing fiB in lots 2 to 8, Lots 2 to 4 are approximately -2'. to -3' below grade. In the
area of iot 5 buttress fills wiil be started. A proof roll was conducted on lots 2 through 8 using a fuily loaded tandem axle
dump truck. Little to no defiection was observed indicating a reiatively stable grade at this time. Kipco moisture-
conditioned fiBs with an onsite water truck and compacted the embankmentwith a sheapsfoot roller, PM: FiB placement
continued in lots 2 through 8. Excavation for the entry road is complete to the second off shoot street. Streets are un-
named at this time. At the 2nd off shoot street grade is approximately -12' from finai grades, Material excavated visually
appears to be sandstone/siltstone residuum overlying weakly cemented 'sandstone/siltstone, To the best of our
knowiedge, the work inspected was in accordance with the building department approved design drawings,
specifications and applicable workmanship provisions of the International Building Codes.
Inspector: Anthony Deluca
CCB #176269
If you have any questions regarding this report, please feel free to contact us at 541-746-9649.
Respectfully Submitted,
i:4~I~_m.
David Smith
Branch Manager
cc: City of Springfield
THIS REPORT IS 1;.,~~..~iM'~,c:1I'IIfHE1omAtlf9\l!1leyrs&"~S~geRi9S'~~9tYEfl5'<r~ai~~~TOA THIRD
. PARTY, ~Y ANY MEANS. EXCEPT IN FULL. WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVI~E INDUS~RI~S. IS PROHIBITED.
l ~~;lInformation
.:;. ,.,~. .To Build On
Engineering. Consulting . Testing
'iR-
DAILY FIELD REPORT
Date Performed:
Client:
Juiy 29, 2009
Hayden Homes
2464 SW GlaCier Place Suite 110
Redmond, OR 97756
Report Number:
722-90076-8
~~: e-li -')T5
Mt Gate Cottages
Mountain Gate Drive
Springfield, Oregon
'045 V+' ClcJe V
Project Name:
Project Location:
PO No.:
Type of Inspection:
Soils Observation
Weather:
Clear
Field Observations and Comments
As requested, a representative of PSI was onsite to observe earthwork operations for the Mountain Gate Cottages, The
entry road is roughly (within 6") to grade, Observation of fully loaded tandem axle dump trucks revealed little to no
deflection indicating a stable grade at this time. Fill placement continued in lots 2 - 8, Lot 2 is approximately at grade. A
proof roll of lots 2 - 8 was performed with awater truck weighing about 50,000 Ibs. Little to no deflection was observed
indicating a relativeiy stable grade at this time. To the best of our knowledge, the work inspected was in accordance with
the building department approved design drawings, specifications and applicable workmanship provisions of the
International Building Codes. '
Inspector: Anthony Deluca
CCB #176269
If you have any questions regarding this report, please feel free to contact us at 541-746-9649.
Respectfully Submi
Professional Serv
lj~1
e Industries, Inc.
Jl
David Smith
Branch Manager
. cc: City of Springfield
THIS REPORT IS PROVIDED FOR THE INFORMA r/ON OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND fTS TRANSMrrTAL TO A THIRD
PARTY, BY ANY MEANS, EXCEPT IN FULL, WfTHOUT THE WRfTTEN PERM.fSSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBfTED.
Professional Service Indust~ies, Inc.. 1040~A Shelley Street. Springfield, OR 97477. Phone 541f746-964.9. fax 541fi46-7163
Cg -01'0
~
l"~;lInformation
",~. .To Build On
Engineering .. Consulting . Tbsting
DAILY FIELD REPORT
Date Performed:
Client:
July 30, 2009
Hayden Homes
2464 SW Glacier Place Suite 110
Redmond, OR 97756
Report Number:
722-90076-9
Project Name:
Mt Gate Cottages
Mountain Gate Drive
Springfield, Oregon
5YS M+ GlCr\-e Dr. l;
Project Location:
PO No.:
Type of Inspection:
Soils Observation
Weather:
Clear
Field Observations and Comments
As requested, a representative of PSI was onsite to observe earthwork progress and proof rollof prepared fiil grades. AI
fully loaded tandem axle water truck was used for the proof roil of lots 2 through 8. Grades range from about final in iot 2
to -7' from final grade in lot 8. Little to no deflection was observed in the grade indicated relative stability at this time. Fills
were moisture-conditioned to around optimum moisture. compactive effort was provided by a sheepsfoot roller. To the
best of our knowiedge, the work inspected was in accordance with the building department approved design drawings,
specifications and applicable workmanship provisions of the International Building Codes.
Inspector: Anthony Del uca
CCB #176269
If you have any questions regarding this report, please feel free to contact us at 541-746-9649.
Respectfuily Submibed,
~~::~_'I"
David Smith
Branch. Manager
cc: City of Springfield
, ,
THIS REPORT IS PROVIDED FOR T~E INFORMATION OF THE CLIENT ONLY. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD
PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED.
Professional Service Industries, Inc.. 1040.A Shelley Street. Springfield, OR 974n. Phone 541(746-9649. Fax,541f746-7163
, "
t9 - 315
\1L
l....~;1 Information
,.,~. .To Build On
Engineering. Consulting. Testing
. DAILY FIELD REPORT
Date Performed:
Client:
July 31, 2009
Hayden Homes
2464 SW Glacier Place Suite 110
Redmond, OR 97756
Report Number:
722-90076-10
Project Name:
Mt Gate Cottages
Mountain Gate Drive
Springfield, Oregon
CSLlS Mt. ~(.lk Dr. G
Project Location:
PO No.:
Type of Inspection:
Soils Observation
Weather:
Ciear
Field Observations and Comments
I As requested, a representative of PSI was onsite to observe and document earthwork operations for the proposed
subdivision. The contractor buiit up the 1 st buttress from 1 of 5 to lot 8. The fill is composed of large angular open
graded boulders, PSI will return on Monday, August 3rd for further documentation. To the best of our knowledge, the
work inspected was in accordance with the building department approved design dravvings, specifications and
applicabie workmanship provisions of the International Building Codes,
Inspector: Anthony Deluca
CCB #176269
If you have any questions regarding this report, piease feel free to contact us at 541-746-9649.
Respectfully Submitted,
~:Ii-""'
David Smith
Branch Manager,
cc: City of Springfield-
THIS REPoRT IS Pf?OV!DED ~OR THE INFORMA TJON OF THE, CLIENT ONLY. THE REPRODUCTION OF THIS ~EPORT, BY ANY METHOD, A:ND ITS TRAN5MITTAL.TO A THIRD
PARTY, BY ANY MEANS, ~CEPT IN FULL, WITH.OUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED.
Professional Service .Industries, Inc. . 1040-A Shelley Street. Springfield, OR 97477 . Phone 541 f746-964~ . Fax 54117 4~. 7"163