HomeMy WebLinkAboutPermit Field Test & Inspection Report 2009-7-28 ..._---- lrfa ~;z Infonnation ,.,~. .To Build On Engineering. Consulting . Testing t9- C031S ~ DAILY FIELD REPORT Date Performed: July 28, 2009 Hayden Homes 2464 SW Giacier Piace Suite .110 Redmond, OR 97756 Report Number: 722-90076-7 Client: Project Name:- Mt Gate Cottages Mountain Gate Drive Springfield, Oregon _ 5Y5 \.At. 0tcrle--1!::1o Project Location: PO No.: Type of Inspection: Soils Observation Weather: Clear Field Observations and Comments AM: As requested, a representative of PSI was onsite to observe and document earthwork operations for the Mountain Gate Cottages. The contractor was placing fiB in lots 2 to 8, Lots 2 to 4 are approximately -2'. to -3' below grade. In the area of iot 5 buttress fills wiil be started. A proof roll was conducted on lots 2 through 8 using a fuily loaded tandem axle dump truck. Little to no defiection was observed indicating a reiatively stable grade at this time. Kipco moisture- conditioned fiBs with an onsite water truck and compacted the embankmentwith a sheapsfoot roller, PM: FiB placement continued in lots 2 through 8. Excavation for the entry road is complete to the second off shoot street. Streets are un- named at this time. At the 2nd off shoot street grade is approximately -12' from finai grades, Material excavated visually appears to be sandstone/siltstone residuum overlying weakly cemented 'sandstone/siltstone, To the best of our knowiedge, the work inspected was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the International Building Codes. Inspector: Anthony Deluca CCB #176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfully Submitted, i:4~I~_m. David Smith Branch Manager cc: City of Springfield THIS REPORT IS 1;.,~~..~iM'~,c:1I'IIfHE1omAtlf9\l!1leyrs&"~S~geRi9S'~~9tYEfl5'<r~ai~~~TOA THIRD . PARTY, ~Y ANY MEANS. EXCEPT IN FULL. WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVI~E INDUS~RI~S. IS PROHIBITED. l ~~;lInformation .:;. ,.,~. .To Build On Engineering. Consulting . Testing 'iR- DAILY FIELD REPORT Date Performed: Client: Juiy 29, 2009 Hayden Homes 2464 SW GlaCier Place Suite 110 Redmond, OR 97756 Report Number: 722-90076-8 ~~: e-li -')T5 Mt Gate Cottages Mountain Gate Drive Springfield, Oregon '045 V+' ClcJe V Project Name: Project Location: PO No.: Type of Inspection: Soils Observation Weather: Clear Field Observations and Comments As requested, a representative of PSI was onsite to observe earthwork operations for the Mountain Gate Cottages, The entry road is roughly (within 6") to grade, Observation of fully loaded tandem axle dump trucks revealed little to no deflection indicating a stable grade at this time. Fill placement continued in lots 2 - 8, Lot 2 is approximately at grade. A proof roll of lots 2 - 8 was performed with awater truck weighing about 50,000 Ibs. Little to no deflection was observed indicating a relativeiy stable grade at this time. To the best of our knowledge, the work inspected was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the International Building Codes. ' Inspector: Anthony Deluca CCB #176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfully Submi Professional Serv lj~1 e Industries, Inc. Jl David Smith Branch Manager . cc: City of Springfield THIS REPORT IS PROVIDED FOR THE INFORMA r/ON OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND fTS TRANSMrrTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WfTHOUT THE WRfTTEN PERM.fSSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBfTED. Professional Service Indust~ies, Inc.. 1040~A Shelley Street. Springfield, OR 97477. Phone 541f746-964.9. fax 541fi46-7163 Cg -01'0 ~ l"~;lInformation ",~. .To Build On Engineering .. Consulting . Tbsting DAILY FIELD REPORT Date Performed: Client: July 30, 2009 Hayden Homes 2464 SW Glacier Place Suite 110 Redmond, OR 97756 Report Number: 722-90076-9 Project Name: Mt Gate Cottages Mountain Gate Drive Springfield, Oregon 5YS M+ GlCr\-e Dr. l; Project Location: PO No.: Type of Inspection: Soils Observation Weather: Clear Field Observations and Comments As requested, a representative of PSI was onsite to observe earthwork progress and proof rollof prepared fiil grades. AI fully loaded tandem axle water truck was used for the proof roil of lots 2 through 8. Grades range from about final in iot 2 to -7' from final grade in lot 8. Little to no deflection was observed in the grade indicated relative stability at this time. Fills were moisture-conditioned to around optimum moisture. compactive effort was provided by a sheepsfoot roller. To the best of our knowiedge, the work inspected was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the International Building Codes. Inspector: Anthony Del uca CCB #176269 If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfuily Submibed, ~~::~_'I" David Smith Branch. Manager cc: City of Springfield , , THIS REPORT IS PROVIDED FOR T~E INFORMATION OF THE CLIENT ONLY. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED. Professional Service Industries, Inc.. 1040.A Shelley Street. Springfield, OR 974n. Phone 541(746-9649. Fax,541f746-7163 , " t9 - 315 \1L l....~;1 Information ,.,~. .To Build On Engineering. Consulting. Testing . DAILY FIELD REPORT Date Performed: Client: July 31, 2009 Hayden Homes 2464 SW Glacier Place Suite 110 Redmond, OR 97756 Report Number: 722-90076-10 Project Name: Mt Gate Cottages Mountain Gate Drive Springfield, Oregon CSLlS Mt. ~(.lk Dr. G Project Location: PO No.: Type of Inspection: Soils Observation Weather: Ciear Field Observations and Comments I As requested, a representative of PSI was onsite to observe and document earthwork operations for the proposed subdivision. The contractor buiit up the 1 st buttress from 1 of 5 to lot 8. The fill is composed of large angular open graded boulders, PSI will return on Monday, August 3rd for further documentation. To the best of our knowledge, the work inspected was in accordance with the building department approved design dravvings, specifications and applicabie workmanship provisions of the International Building Codes, Inspector: Anthony Deluca CCB #176269 If you have any questions regarding this report, piease feel free to contact us at 541-746-9649. Respectfully Submitted, ~:Ii-""' David Smith Branch Manager, cc: City of Springfield- THIS REPoRT IS Pf?OV!DED ~OR THE INFORMA TJON OF THE, CLIENT ONLY. THE REPRODUCTION OF THIS ~EPORT, BY ANY METHOD, A:ND ITS TRAN5MITTAL.TO A THIRD PARTY, BY ANY MEANS, ~CEPT IN FULL, WITH.OUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED. Professional Service .Industries, Inc. . 1040-A Shelley Street. Springfield, OR 97477 . Phone 541 f746-964~ . Fax 54117 4~. 7"163