HomeMy WebLinkAboutOccupancy Correspondence 1993-8-18
..
SPR,.IIELD
225 FIFTH STREET
SPRINGFIELD. OR 97477
(503) 726-3753
FAX (503) 726-3689
CERTIFIED LETTER
August 18, 1993
*
James Eastburn
1375 52nd Street
Springfield, OR 97478
Subject:
Occupancy Inspection at 3205 Main Street, Springfield. Oregon.
Proposed Use:
Retail Car Sales
Dear J\:1r. Eastburn:
At )'our request, the Community Services Dh'ision/Building Safety conducted an inspection
of the building at the above address. The purpose of the inspection was to determine the
suitability of the building for the proposed use as indicated.
Based on the proposed occupancy, the existing conditions which are mentioned below do
not meet the minimum Building Safety Code requirements. Corrective measures must be
taken prior to occupancy to instalI,-repafr, replace or modify the following items in order
for the building to conform to applicable safety codes: .
Structural
1. Install a handrail not less than 34" or more than 38" above the line of nosings of the
treads. Ends of the handrail shall return to newel posts.
2. The required inspection approvals associated with City permit #930225 issued March
8, 1993, must be obtained. These inspection approvals consist of: storm sewer,
rough grading, final paving, final building, and final site plan review.
3. Address numbers shall be posted on the front of the building in a place that is
plainly "isible from the street.
..
.
James Eastburn
Occupancy Inspection
Page 2
Fire
4. Provide one class 2A fire extinguisher mounted in an approved location three to five
feet from the finished floor.
Electrical
5. Ground fault circuit interrupter protection (GFCI) is required for all receptacle
outlets in the garage area.
Compliance with the Planning Department, Fire Department, Department of Environmental
Quality (DEQ), and Building Safety requirements are required prior to issuing occupancy
approval,
If you need any further information or have any questions regarding the above
requirements, please contact the appropriate inspector noted below between the hours of
8:00-9:00 a.m., 1:00-2:00 p.m., or 4:00-4:30 p.m. at 726-3759.
Sincerely,
--r O\oy\ Yv\ ~
Tom Marx
Building Inspector
~~~
Jim Hays
Electrical Inspector