Loading...
HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2009-7-31 ~ Sfcl Page 1 of 1 11~'IINCI;1I1~.'~:'II'I~.lll. Geotechnical & Construclion Services Daily Field Report Client: EWEB 500E. 41h Ave. Eugene, Oregon, Project: Hayden Bridge Water Filtration Plant Expansion Springfield, Oregon ~'\'S., \-\o.'lcj.-c,.n e,ri~~ QP.. Date:, Project No,: Report No.: Inspector: ID No.: 07-31-09 2087168 . E-23535 A. Fenstermacher 5258882-49 ICC Inspection of: Reinforced Concrete Contractor: Wildish Building Co. Weather:-Clear- BP N9..: _._?.o08,00225 Continuous Inspection: 0 Periodic Inspection: 1>'1 Performed final inspection on the reinforcing steel in new flume wall, north 40' section and the 40' to 80' section, from the south end, and the slab on grade for the alum truck unloading and fill station. A preliminary inspection was performed on 07-30-09 (ref: FEI report E-23513). Observed the placement of 18.0 yards of Knife River 4000 psi concrete (mix 40-SE7) into areas noted above. Concrete was placed by pump and was mechanically consolidated. Cast one (1) set of four (4) 4" x 8" compressive strength cylinders. Notified Mike Stickling (EWEB) and Jake Stucky (Wildish) of the on-site results. Slump - 7 3/4"; concrete temperature - 79F; air temperature - 69F; air content - 6.5%. Mr. Stucky was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected was in accordance with plans dated 02/2008 and applicable workmanship provisions of the I.B.C" except if noted above. Reviewed By: ;h .--/~ Michael L. "Me!Z Technical Manager c: EWEB- Mike Stickling (email) EWEB- Wally McCullough (email) OBEC- Pete Slocum (emall) Wildish Building Co.- Kevin Fitzjarrell (email) Wildish Building Co.- Jake Stucky (em ail) City of Springfield MLM:sc This report and/or enclosed t.est data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Test"ing & Inspection, Inc.'s.written authorization. 7m NoN Cornell Avenue' Corvallis, Oregon 97330. phone (541) 757-4698. fax (541) 757-2991 29540 BAirportRoad' Eugene, 0regJn 97402, phone (541) 684J849 . fax (541)684-3851 62979 NE Plateau Drive, Suite 3 . Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846 . yJ- ~ftJ Page 1 of 1 11a.'ltml;"II"-'~='.lllh'.I~I. Geotechnical & Construcfun Servires Daily Field Report Client: EWEB 500E. 4th Ave. Eugene, Oregon Project: Hayden Bridge Water Filtration Plant Expansion Springfield, Oregon O~S.., H().)jOU\ Bncl.t"- ~. Date: Project No.: Report No.: Inspector: 10 No.: 07-30-09 2087168 E-23513 D. Delatte 1080867-88 ICC Inspection of: Reinforcing Steel Contractor: Wild ish Building Weather: Clear SP'No.: 2008-00225 Continuous Inspection: 0 Periodic Inspection: 0 Performed preliminary inspection on the reinforcing steel in new flume wall, the north 40' section and the 40' to 80' section from south, end, and slab on grade for alum truck unloading and fill station pad, Reinforcing steel was checked for grade, size, lap, placement and clearance. Reinforcing steel was secured with tie wire and supported above grade, To the best of our knowledge, the work inspected was in accordance with plans dated 02/2008 and applicable workmanship provisions of the I.B.C., except if noted above. Reviewed By: ;Jt.~.~ Michael ~. Mdver Technical Manager c: EWEB- Mike Stickling (email) EWEB- Wally McCullough (email) OSEC- Pete Slocum (email) Wildish Building Co.- Kevin Fitzjarrell (em ail) Wild ish Building Co.- Jake Stucky (email) City of Springfield MLM:sc -i>~ ~ ~, CJ ~ This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific ; ~. process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part (p thereof be disclosed without FEl Testing & Inspection, Inc.'s written authorization. 750 NW ComeIIAvenue - CorvaIIs, CXegon 97330. phone (541) 757-4698, fax (541) 757-2991 29540 BAirpatRoad' Eugene, Qegon 97402, phone (541) 684J849 'fax(541)684-J851 62979 NE Plateau Drive, Suite 3 . Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846