HomeMy WebLinkAboutSpecial Inspection Correspondence 1979-12-26
.
.
CITY OF SPRINGFIELD
SPRINGFIELD. OREGON 97477
PUBLIC WORKS December 26, 1979
346 MAIN STREET
726.3753
~Ir. J, W, Hooten
4090 Main Street
Springfield, Oregon 97477
Dear ~lr. Hooten:
At your request, the Building Division of the City of Springfield made an
occupancy inspection on December 19, 1979 at 4090 Main Street eScotts Trad-
ing Post), Springfield, Oregon. The establishment of a second business in
this building necessitated this inspection,
The present use of the building is a retail store which is a B-2 occupancy,
The proposed use of the hardware store in the other half of the building is
also a B-2 occupancy. The building is located in Fire Zone 3.
For the building to conform to the applicable codes, the follOl;ing items
must be repaired, replaced or installed:
1) The pressure relief valve on the saterheater in the bathroom is to be
piped to within 8 inches of the floor.
2) There shall be a floor or landing on each side of a door. The floor or
landing shall not be more than 1 inch lower than the threshold of the
doorway, Where doors open over landings, the landing shall have a length
of not less than 5 feet. ' .
3) An electrical permit is required for all electrical work. The electrical
work is to be done by a licensed electrical contractor and inspected and
approved by the City of Springfield's electrical inspectors.
All applicable permits. must be obtained before work starts and all work must
be inspected and approved before a Certificate of Compliance will.be issued,
Please direct all inquiries to the Springfield Building Division at 726-3753.
Sincerely,
. ,,-,1 :rrr--' J~C--vv--
Tom Sheirbon
Permit Coordinator
TS/lj
~'
~