Loading...
HomeMy WebLinkAboutPermit Building 1993-8-17 '- . . COMM ERCIAL/lN DUSTRIAL PERMIT APPLICATION s~ JOB NUMBER q~ I 'd.-:JLf INSPECTION LINE: 726.3769 OFFICE: 726-3759 225 Fifth Street, Springfieid, Oregon 97477 LOCATION OF PROPOSED WORK: ASSESSORS MAP: 40-;)./ \tYI nA~ l,o";J. ?..j'-l' .1,,:f/\ P p;l . TAX LOT: o(~qn('J OWNER: t\~CV\(). lJ.)Qf\r.i.J ~1CJ'..f) ~1,~ J ADDRESS: l-40;1, VY\r. ;-,,^-J M^ Q D7L CITY: 4pv:, V"'I::i~q P& STATE: -it\ P V'l')l'ltJ PHONE: j4/-" Li/YS o'R. ZIP: Cf'J'-li 'k DESCRIPTION OF WORK: (3., .,..frl,vv;. DEMOLIS~ OTHER ~I ..~~. .. . VALUE: 1/ . ,.".- '% ~ '-t I"J() .. NEW REMODEL ADDITION NAME ADDRESS PHONE ARCHITECT' CONTRACTOR'S NAME GENERAL: CWo ~ok ADDRESS hrl\~~-L '-10'&0 CONST. co NT RACTO R # W- IlkNA-w. crU(j- '1"140;:1 EXPIRES c; 4 :::l_hl../ PHONE "1/,;)..19", ~'-1:;l. ....177 PLUMBING' MECHANICA' . ELECTRICAl' NO. FEE CHf,RGE Nn ~~~ I "HABGE-l PLI'MBING MECHANICAL Storm Sewer It. Furnace/burner & vent < 100.000 BTUs Furnace/burner & vent > 100.000 BTUs Floor furnace and vent Suspended wall or floar mounted unit heater Appliance Vent separate Stationary evap. cooler Vent Fan/Single duel Vent System apart from AC or htg. Mechanical exhaust hood and duct r Single Fixture Relocated Bldg. (new fix. add!1I Water Service ft. Sanitary Sewer It. Backflow Device Permit Issuance $10.00 TOTAL PERMIT TOTAL PERMIT - OFFICE USE - HANDICAP ACCESS' OUAD AREA' LAND USE: cLOOD PLAIN' # OF BLDG~' # OF UNIT~' ZONING: # OF STORIES: CONSTR. TYPF' HEAT SOURCE:. LIGHTING POWER BUDGET: WATER HEATER' OCCY GROUP' sa. FT. $/50. FT. VALUE SO. FTG MAIN X X sa. FTG ACCESS sa. FTG OTHER X TOTAL VALUE OF .PROJECT PLAN CHECK F~~ RCPT' OAT~ BY I BUILDING PERMIT [5% State Surcharge I MECHANICAL 15% Stale SurcharQe I PAVING L/l.j s. 0 ~ .:::>2. PLUMBING DEMOLITION 5% State Surcharge FENCE VALUE $. SIDEWALK CURBCUT FT. FT. SUBTOTAL PERMITS SYSTEMS DEVE'LOPMENT TOTAL PERMIT FEES I EXCLUDING ELECTRICA' ~ 1410.73 . . REQUIRED INSPECTIONS I It Is the responsibility of the permit holder to see that all inspections are made at tile proper time. To request an inspection, call 726.3769 (recorder), state your City designated jOb number, job address, type of inspection requested and when you will be ready for Inspection. Requests received before 7:00 a.m. will be made the same working day, requests made after 7:00 a,m. will be made the following work day. SITE INSPECTION: To be made after excavation, but prior to setup of forms. UNDERSLAB PLUMBING, ELECTRICAL & MECHANICAL: To be made before any work is covered, ROUGH PLUMBING, ELECTRICAL & MECHANICAL: No work is to be covered until these inspections have been made and approved. PAVING: After gravel is in place but prior to placing asphalt or concrete, FOOTINGS & FOUNDATIONS: To be made after trenches are excavated and forms are erected, all steel In place, but prior to placing concrete. FIREPLACE: Prior to piacing facing materials and before framing inspection. SPECIAL INSPECTIONS: In accordance Section 306 of the State Specialty Code a special inspector shall be employed by the Owner! Contractor during construction of the following work, A copy of the special testing reports shall be furnished to the Building Division. ATTIC DRAFT STOPS & CURTAIN WALLS CONCRETE SLAB: To be made after all Inslab building service equipment, conduit, piping, accessorles and other ancillary equipment items are in place but before any concrete is placed. FRAMING: To be made afler the roof, all framing, fire blocking and bracing are in place and all pipes, chimneys and vents are complete and the rough electrical, plumbing and mechanical are approved. STRUCTURAL CONCRETE: In excess of 2500 PS.1. (306 a.l) STRUCTURAL WELDS: Performed on the job. (2722 f) UNDERGROUND: Plumbing, electrical, gas, sanitary sewer, storm sewer, water and drainage lines, To be made prior to covering or filling trenches. INSULATION & VAPOR BARRIER: To be made after all insulation and required vapor barriers are In place but before any lath or gypsum board Interior wall covering is applied. HIGH STRENGTH BOLTING: During all bolt installation and tightening operations. (306 a.6) SPRAYED ON FIREPROOFING: U.S.C. Standard~ 43.8. UNDERFLOOR: Plumbing, electrical, mechanical. To be made prior to Installation of floor insulation, decking or floor sheathing. FIRE & SEPARATION WALL: Located and constructed according to plans. SPECIAL GRADING, EXCAVATION AND FILLING: During earthwork. (306 a.ll & Chapter 29) POST & BEAM: To be made prior to Installation of floor Insulation, decking or floor sheathing. LATH ANDIOR GYPSUM BOARD: To be made after all lathing and gypsum board, Interior and exterior, is In place but before any plastering Is applied or before gypsum board Joints and fasteners are taped and finished. GLU.LAM SEAMS: Inspection Certificate by an approved agency, furnished to the City's Building Division before beams are placed. (2501 U.BC. STDS. 25.10,11). FLOOR INSULATION & VAPOR BARRIERS: To be made prior to installation of decking or floor sheathing. STRUCTURAL MASONRY: (306 a.7) MASONRY: Steel location. bond beams grouting or verticals in accordance with USC 2415. SIDEWALK & DRIVEWAY: Required for all concrete paving within street right of way, to be made after all excavating complete and form work and sub-base material in place. .In addition to the inspec- tions specified, the Building Official may make or require other inspections of any construction work to ensure compliance with the Bui/ding, City or Development Code. y ROOF SHEATHING AND NAILING: Prior to installing any roof covering. CURB AND APPROACH APRONS: After forms are erected but prior to placIng concrete. ------------------------------------------------------- FINAL PLUMBING SITE PLAN REVIEW BOARD: Must be requested 2 days in advance of the date you wish inspection. All project conditions such as landscaping, parking lot striping, etc. must be completed before requesting this inspection. FINAL ELECTRICAL :, FINAL MECHANICAL FINAL BUILDING: Requested after the final plumbing, electrical, mechanical and Fire Department inspections are made and approved. No occupancy of the premises can be made until a Certificate of Occupancy has been issued by the Building Division and posted on the premIses. FINAL FIRE DEPARTMENT ADDITIONAL COMMENTS: PLANS REVIEWED BY OAT" By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all Information herein Is true and correct, and I further certify that any and all work performed shall be done In accordance with the Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Building Safety Division. I further certify that only contractors and employees who are In compliance with ORS 701.055 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that project address is readable from the street, that the permit rd Is located at the front of the property, and the approved set of plans will remain on the site at all times d ring const etl n. <--J/P7~~~ Date ~6?' VAliDATION: AMOUNT RECEIVED: .tJ WJ.:,,:7 ~ DATE PAID: 1S/J.:::Llg ?, RECEIPT H' 0VliO RECEIVED BY: 1O~ l""'-"'.!15!!.J"""'V"" ''"'~IU!!r,........ "'T ;'-ft~:- . 'J-:;;-~\lir.-:;~ ,~, , ,."'" !/'oo=~5''=4 .Q.,n~q':;'tifof . I /1 1 i I --, '''''0:',.- '-:'-7"","l1. Clark Brown CnrpOInr" COI}lrntlr>r '. :i'i..\ ,,' Q U Tacolime" ,1..,. . ;1' '.' Proposa~ , ,I May 28,1993 4089 W. 11th Ave. Eugene, Oregon 97402-5C_ (503) 342-4177 FaX# (503)343-5104 CCB # 54264 TACO TIME INTERNATIONAL. 'Ne, p.o. Box 2056 . 3880 West l11h Avonuo Eugene, Qrenon 97402 USA Ph. 503.687.8222 . rAX 503.343.5208 ,.800-547.8907 ALL-ROOFS NORTHWE Submitted to: Maury Triden Triden Tn-Services Phone: 485-3037 5120 Center Way Eugene, OR 97405 Taco Time (Fonziesl"'" ~~ WarL 0\()1I\e.Y jopcu-aior 40th & Main 7' /I / I ( "S Springfield, OR 97478 ~ '-t' ~ Job site: = Remove existing roofing on the built-up sloped area at the above business. Haul away debris. Install a new 20 year fiberglass buill-up roofing system with a mineral-surfaced cap sheet roof membrane. Install new cant strip at the base of parapet walls (entire wall perimeter). Turn roofing up interior portion of wall. Provide counter flashing behind new T 1-11 siding at perimeter wall to top of existing wood cap and flashing. , , ., I I I i ._1 Presently there is no base flashing thai is adequately serving this purpose and the existing plywood on th'e walls is simply but~; ,;,,,~,, JU""~ water getting behind .t~e roof syste~~._. .~ 5.% _m_J . . ~ ~'\~-'. .... ._I""':f#~=~I~'~~~~~~iJl~.' .,. .- ,....o/.."""'M1.~~~~~.I~ ':P'C(il, .. ';t~~\lll(X~"'~ 1_.- ~em~}~" ,~~ II.~>'~ .. Tc...c...o liMo{, ~e..~ \..oVc-f"k- ~it'\..,{ . AvPf'ClK. ~VV\~ k>~l"""" 3 LoUeeV-S -&o~ io~ II 1, Ii I Page 2 5/28/93 .. ~ Manville -.,--'" !J.1.. CI~ssific~liolls Class A Max. Slope: 1V2' Deck: Non-Combust. Insulation: Fesco, FesCore, Fesco-Foam. UltraGard Gold. none Surfacing: Cap Sheet Max. Slope: 1" Deck: Combustible Insulation: Fesco, FesCore, Fesco-Foam, UltraGard Gold, none Surfacing: Cap Sheet Class B (see Ctass A) Max. Slope: 3" Deck: Non-Combust. Insulation:' Fesco, FesCore, Fesco.Foam, UltraGard Gold, none Surfacing: Cap Sheet Class C (see Class A & B) . Four Ply Mineral-Surface Fiber Glass Built-Up Roofs Non.Nailable Deck or Approved Insulation Concrete Primer (If Required) Asphalt Q) Cl 1\I c: '0; ~ o . Specification No. 4GIC For use over Concrete or other Non-Nailable Decks and Fesco@ Board, Fes-Core~, Fesco-Foam@, UltraGard GoldT~ or Approved Insulation on Inclines of W' to 6" per Foot For Regions 1, 2, & 3 -~. ...~...., ~.,..,.- " - '.'..., .....,,,"'--.,,.......,,'.... .-...... " Asphalt ~.-:.....::~::....:: '....... . ,... 2"1 .: '. ::. :. '.' , .... , '.' :.:....':l...:..;:...:<...:.:..:: '.' '." GlasKap ':'., '.' : " . t " Mineral Surface. . , : ~ .: . Cap Sheet.. ..'. ..'. . ' , . '. '. . . . . End Laps Broken .: '.: .' . 3' Apart (Min.) .... .. I""", .' .... . ..=.-:.:....:-.:-i:'........:-,. 2" . .... '. ..,.-:-6" End Lap .,' GlasPly Premier or GlasPly IV I " . '. ..to.'.::.:. . M. ',' . . . . .' .. . . . Asphalt . ,.... ,.' r :. . '.. .. .,. -- _..."'....,......'..~.,_,.._, .."......_ ,., .,'._."""'__,.,,~'.._..oaJ_ ~ ~~ --.............".---.. -.., '. ,-...~<.~._.~- ~~.,'-- .ot G~n~rnl This specification is for use over any type of structural deck which is not nailable and which offers a suitable surface to receive the roof. Poured and pre-cast con- crete decks require priming. It is also for use over Fesco", Fes-Core '.. Fesco-Foam"', UllraGard Gold ,. or other approved insulation which offers a suitable surface to receive the roof. This specification is not to be used over light.weight insulating concrete decks either poured or pre-cast or over fill made of light-weight insulating concrete. Note: All general instructions contained in thecurrentManville Industrial/Commercial Roofing Systems Manual shall be con- sidered part of this specification. Flashings: See section on BUR Flashings, Manville Industrial/Commercial Roofing Systems Manual. .n? M:1fefi:lls per 100 Sf? ff of f(Jof men Concrete Primer: If required .1 gal. Felts: GlasPIy" PremierorGlasPly"'.IV...... .3 plies GlasKap"' Mineral Surfaced Cap Sheet. . . . .1 layer Bitumen: Refer to Para. 7.7 or 11.0.3.2 Approx. installed weight (Ibs.): 224.226. .03 ^rrli~~I.i(l1l of Roofing Starting at the low edge of the roof area apply one 12" wide, then a 24" wide, then a full 36" wide GlasPly Premier or GlasPly IV. All following felts are to be applied full width overlapping the preceding felt by 24'/3' giving a minimum of 3 plies at all points. Install each felt so that it shall be firmly and uniformly set, without voids, into the hot asphalt (within 250 F of the EVT) applied just before the felt at a nominal uniform rate of 23 Ibs. per square over the entire surface. Prior to application, cut the cap sheet into handleable lengths (12'-18') and allow to flatten. When nailing is required, cut the cap sheet into lengths which conform to the nailer spacing. Starting at the low edge of the roof area, apply one layer of the cap sheet, being sure to maintain 2" side laps and 6" end laps over the preceding sheets. Apply the cap sheet in a full width mopping of hot asphalt (approx. 200 F above the EVT to maximize bonding of the cap sheet to the ply sheets) at the approx. rate of 23/lbs/sq to the ply sheet(s), also applying asphalt to the side lap area on the backside of the cap sheet. Then flop the cap sheet into the hot asphalt. At ambient temperatures below 700 F, see the cold applica- tion section of the Manville Industrial/Commercial Roofing Systems Manual. The cap sheet must be firmly and uniformly set into the hot asphalt with all edges well sealed. Nailing: For slopes greater than 1" per foot: nailing is required. Refer to Para. 10.1 & 11.0.5 or 11.1. 'GlasPly Premier required for No Dollar Limit (NOL) Guarantees. I -I I I I I ~ .~ IJU.560SC'c.11 Pg. 15 11.67