Loading...
HomeMy WebLinkAboutSpecial Inspection Correspondence 1980-5-29 v , . . ,'Ii :.- -- ...( -., CITY OF SPRINGFIELD SPRINGFIELD. OREGON 97477 DEPARTMENT OF PUB lIC WOR KS May 29, 1980 346 MAIN STREET 726.3753 CERTIFIED LETTER Mr. Clifford Gleghorn c/o May Greer 1234 "c" Street Springfield, Oregon 97477 ,~ Dear Mr. Gleghorn: At the request of the tenant, a courtesy inspection was conducted at 4535 and 4537 Main Street, Springfield, Oregon, relative to specific items suspected to be in violation of the Uniform Housing Code as adopted by the City of Spring- field. The following items are in violation: ELECTRICAL SAFETY The electrical system has been improperly altered and maintained and constitutes hazardous wiring as described in Section 1001(e) of the Uniform Housing Code as adopted by the City of Springfield: A) 4535 Main Street: 1) Rewire water heater over current device through the main disconnect (60 amp pull out). (Section 230-82 & 230-90(2) of the National Electrical Code (N.E.C. )) 2) Replace the defective light fixture in the bathroom and repair all the fixtures to have an insulated pull chain where there are no wall switches. (Section 4l0-l8(b) of N.E.C.) B) 4537 Main Street: 1) Install the service grounding conductor (#6 copper) to an approved ground rod. (Section 250-92 of N.E.C.) 2) Bond the cold water system within the building (#6 copper). (Section 250-80 of N.E.C.) 3) Properly seal all open knockouts in the panel and replace all missing screws.. (Section 370-8 of N.E.C.) 4) Install an insulating grounding bushing on the service conduit into the panel. (Section 250-72 of N,E.C.) ,- .- . . " -1 Ceur~esy Inspection "--.4535 & 4537 Main Street Mr. Clifford Gleghorn May 29, 1980 Page 2. 5) Box in open cables below panel level. -(Section 336-6(b) of N.E.C.) 6) Install insulators on pull chains out of light fixtures. (Section 410(b) of N.E.C.) All necessary permits shall be obtained before work starts and all work shall b~ac- complished according to applicable codes and inspected by this office. All work in both units must be corrected by a licensed electrical contractor as specified in Sec- tion 22-110 (l)(b) of the Oregon Electrical Standards. SANITATION: -, In addition, debris from a previously existing house has been left on the property. This condition constitutes a violation of Section 401 of the Uniform Housing Code as adopted.by the City of Springfield relative to nuisances. The debris must be cleaned up and removed. If the house was connected to the sanitary sewer, the sewer must be capped off at the property line. A plumbing permit must .be obtained and the sewer cap must be inspected by .this office. If the house was connected to a septic tank, the septic tank must be pumped and filled with clean bar-run gravel or other approved material. Therefore, by 30 days from the date of this letter (June 29, 1980), the above stated violations must be corrected. An inspection will be conducted on that date to ensure compliance with the Springfield Housing Code. Your anticipated cooperation is appre- ciated. c Please direct all inquiries to the Springfield Building Division at 726-3753. Sincerely, /--"- ~ ----- ".-::-e?~ <--' /..# _. "'" -' / ~....., .-. ---....> Sally Johnson Environmental Inspector cc: Charlie Watson Electrical Inspector Ronald B. Clark Superintendent of Building Joseph J. Leahy Assistant City Attorney Tenants 4535 & 4537 Main Street Springfield, Oregon 97477 SJ/lj 'ob N':""' IN}/; U-"CiTY'~gf1~~GFIELt- '^" 6-- 1& - 80 BUILtllNG DIVISION 346 MAIN STREET 726-3753 WE HAVE INSPECTED THE ELECTRICAL WIRING AND EQUIPMENT INSTALLED BY YOU AT THE PREMISES NAMED HEREIN AND SUBMIT THIS 'REPORT FOR YOUR RECORDS. ~ TO Hi''} vi flryfp,o ~ 0 TEN~R~R I; .:i34 'r) sf, lOCAJb~N OF f.j 3~~ )f,.;}/,# , o WIRING APPROVED FOR COVER 0 A PERMIT IS REQUIRED o APPROVED FOR SERVICE 0 HEAT CABLE APPROVED FOR COVER o WIRING INCOMPlEl'E 0 UNDERGROUND APPROVED FOR COVER o WIRING COVERED WITHOUT INSPECTtON 0 CONDUIT SYSTEM APPROVED FOR COVER o DUE TO THESE PREMISES BEING LOCKED AN INSPECTION COULD NOT BE MADE o DUE TO NO ONE HOME AN INSPECION COULD NOT BE MADE o WIRING APPROVED FOR COVERING EXCEPT THE FOLLOWING (r1. _ Q) jPt'j,JL,.,.f> WiJ~.y\ J~.:Jte>^ nj/p~I./'t''Y'~YJt ~V/~P t/,yU M.:J/j1 cf'<;'(!p"'<J1c"C'i3 (bOA~ .outlM,t) J"<!'(". ~~o-F2 +- S<!C. ~Jo-'lor.) . ~ :' ~ -~ 9, . ~~ ' !/ . c r,,), -,~ . .Y' r/}./PO;}n'.] ~~~~, .1:/~a;:< ';;;;JL-1fO ~:~+ ~~.~ .. ;:,p .yp W r J "c1:i,~b:Et.!;::!u'~on Cj.~-a 3-z,.~3z/_,_,." ?::.. ?~O .. (! , 14i'&"11 INSPECTOR. ~'1//lJ ,/;"nNn;l CITY OF {SPRINGFIELD rt&.-rf/~U-X-/~ /'7 t:? '2 ., .. .. .-: ...7.-,.....".;.,.~..,... .". ,'. ~ .' '''':~'',''''' ".' ."".:,i'..:.,:;.J."'..'... Job Number () (1 t:. 'l. L D/:.iE- J 6 -IJ() BUilDING DIVISION 346 MAIN STREET 726.3753 WE'HAVE INSPECTED THE elECTRICAL WIRING AND EQUIPMENT INSTALLED BY YOU AT THE PREMISES NAMED HEREIN AND SUBMIT THIS REPORT FOR YOUR RECORDS. . .......--- AA_ LZ OWtlErloR TO /7rl~ qi"el"'/I TENANT . . 12..~4 ~ ' . PI- lOCAJb~N OF f,C ~ 7 ,Mdi.n S/h.,. o WIRING APPROVED FOR COVER 0 A PERMIT is REQUIRED. o APPROVED FOR SERViCE 0 HEAT CABLE APPROVED FOR COVER o WIRING INCOMPlEl'E 0 UNDERGROUND APPROVED FOR COVER o WIRING COVERED WiTHOUT INSPECTION 0 CONDUIT SYSTEM APPROVED FOR COVER o DUE TO THESE PREMiSES BBNG lOCKED AN INSPECTION COULD NOT BE MADE . 0 DUE TO NO ONE HOME AN fNSPECfON COULD NOT BE MADE