Loading...
HomeMy WebLinkAboutSpecial Inspection Correspondence 1996-2-29 v . DEVELOPMENT SERVICES DEPARTMENT 225 FIFTH STREET SPRINGFIELD, OR 97477 (541) 726-3753 FAX (541) 726-3689 February 29, 1996 ~ Norman L. Frank 2511 Lily Avenue Eugene, OR 97408 Subject: Occupancy Inspection at .!iQ2 & 4413 Main Street Proposed Use: 4405 Main, Antique and second-hand furniture dealer 4413 Main, Beauty Salon Dear Mr. Frank: At your request, the Community Services Division/Building Safety conducted an inspection of the building at the above address. The purpose of the inspection was to determine the suitability of the building for the proposed uses as indicated. Based on the proposed uses, the existing conditions which are mentioned below do not meet the minimum Building Safety Code requirements . Corrective' measures must be taken prior to occupancy to install, repair, replace or modify the following items in order for the building to conform to applicable safety codes: Structural 1. An inspection of the paved parking area revealed that no parking spaces a designated for handicapped individuals. One VAN ACCESSIBLE parking space shall be provided with appropriate striping and signage as per the attached excerpt from the State DOT requirements. 2. It is our understanding that you intend to plug off the ceiling supply registers to the easterly lease space (4413 Main Street), and install electric wall heaters to heat that space. We have concern for the ventilation provisions required by the Code, as follows: Enclosed portions of buildings. customarily occupied by human beings shall be provided with natural ventilation by means of exterior openings with an openable area not less than 1/20th of the total floor area of such portions, or shall be provided with a mechanically operated ventilating system. The mechanically operated system shall be capable of supplying a minimum of 5 CFM of outside air per occupant with a total circulated of not less than 15 CFM per occupant in all occupied portions of the building. Since the only natural ventilation option to the proposed beauty salon space is to open the door, we feel that a mechanically operated ventilation system is the sensible ./ . . option. With the odor producing chemicals involved in hair and nail treatment, it is particularly important to provide good ventilation and introduction of outside air into spaces like the beauty salon. Please coordinate ventilation provisions intended with the City Inspectors prior to occupancy of the lease space. .- 3. Exits shall be illuminated at any time the building is occupied with light having intensity of not less than 1 footcandle at floor level. Since the only apparent means of turning off the ceiling light fixtures is at the panels, a night light shall be provided in each lease space to provide the level of exit illumination required when the normal lighting is turned off. 4. Since the entry door hardware into the two lease spaces is of the type which has a thumb turn deadbolt from the inside, please provide signage at each of the doors stating, "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS.". 5. It is our understanding that the lease tenant in the beauty salon space wishes to install a reception table in front of one of the two front exit doors from that lease space. The second door is not a required exit door, but shall be altered so it does not look like an exit door so no person would try to use it in case of an emergency. 6. It is our understanding that even though two toilet rooms are provided at the rear of the lease spaces, you intend to use them as unisex toilet rooms, with the easterly toilet being used by an existing lease tenant to the east of these lease spaces, and the westerly toilet being used by these two proposed tenants. Unisex toilets are approved for up to a maximum of 10 employees, but shall be provided with a privacy latch and an "OCCUPIED" indicator. We observed that an approved privacy latch exists on both toilet room doors, but "OCCUPIED" indicators shall be added. Questions regarding the above items may be directed to Lorne Pleger, Plans Examiner/Structural Inspector, at 726-3669. Plumbina: 1. It is our understanding that the Beauty Salon tenant wishes to install a shampoo sink which will have its waste piping connected to existing waste piping which served a former sink about 8' from the proposed sink location. The new shampoo sink shall be installed with proper waste trap and vent, and the vent shall either be extended through the roof at the new location, or shall be installed one size larger than required and connected in the attic space to the existing primary vent serving the toilet rooms. Please coordinate specific inspection and installation requirements for the new plumbing fixture with Ralph Shaw, City Plumbing Inspector, at 726-3665. .r . . Electrical: 1. Please refer to the electrical corrections listed in the . former occupancy inspection letter dated May 18, 1995, and verify that those corrections have been made. Questions regarding electrical installation or inspection requirements should be directed to Dave Gadomski, City' Electrical Inspector, at 726-3663. Sincerely, orne Pleger, Plans Examiner/Structural Inspector