HomeMy WebLinkAboutPermit Electrical 1992-6-17 SI.IIINt;r-IELD ~"'Ji ~. 225 FIITH STREET 'Tho !Q:l~...i"g projeel as 8ubmlltad _lIiii.,.........", AL PERKIT APPLICATION \ SPRINGFIELD, OREGON 97477 zonin\J,endd(;(j3n~ulWllh" O'? ('""(:LA INSPECTION REQUEST: 726_3M(01iel. Ci ty Job Number - \ ...LJ C{) OFFICE: 726-3759 Zon!!!q ..', \ ,~X \. O. COHPLETE FEE SCHEDULE BELOV ~ 1. LOCATION OF INSTAL~TI~. . '~ <::? ~ t::;" Jvfl,}.rA/ AIIll\C;izGl:S:gn.tu~l\\ No" lI^rillllRtial-Single or . Hulti-Family per dwelling unit. \I~~:~ION t\.~\n() Service Included: Items Cost ' Sum ~OA. DESCRIPTIOlj ( .J \. '\ i\\,\. \ ,-t:5:\) " Permits are non-transferable and expire if work is not started within 180 days of issuance or if work is suspended for 180 days. 2. CONTRACTOR INSTALLATION ONLY B. Electrical Contractor rJIX-O!Ll Fi.F:/. Add ress ,,< l-/ / L/ D E:.i _ MANa (''-...-' City ~I/I,&l/i;' Phone 7Lfl/-o!rlJ Supervisor License Number :5 iPfl.f6 o Expiration Date 1(9-1- 9' 7. Constr Contr. Number J.f. ~ 0/ L/ 1000 sq.ft. or less Each additional 500 sq. ft or portion thereof Each Hanuf'd Home or Modular Dwelling Service or Feeder Services or Feeders Installation, Alterations or Relocation: . 200 amps or less 201 amps to 400 amps 401 amps to 600 amps 601 amps to 1000 amps Over 1000 amps/volts Reconnect Only $ 85.00 $ 15.00 $ 40.00 $ 50.00 $ 60.00 $100.00 $130.00 $300.00 $ 40.00 C. Temporary Services or Feeders Installation, Alteration or Relocation Signature of Supervising Electrician ,.,}/JM ~j ow:ers Qame t\ X" . ~ \.In.\\ Address ~G ~> V\-\.aR CityRr-\\-\n ;hone 1~\O:\()~~~:~hC~~~~~~onal ' ~t\ -. . Circuit or with Service OIINER INSJALLATION or Feeder Permi t '1 $ The'installation is being made on E. Miscellan'eous (sertce~der property I own which is not intended -Each installation for sale, lease or rent. Pump or irrigation Sign/Outline Lighting Limi ted Energy/Re's Limited Energy/Comm Expiration Date t: /z--.; 9'~ ; Owners Signature: 200 amps or less 201 amps to 400 amps Over 401 to 600 amps Over 600 amps or 1000 D. Branch Circuits New, Alteration or volts $ 40.00 $ 55.00 $ 80.00 see "Bn above Extension Per Panel $ 35.00 ~ ~~;~~--~-~-l-[-;;-:~~~----------J-~~/';~~~~~;~; ~~r~~~~e RECEIPT #: ~ ~r.:::>.- \5\'ll"")J 7f!fl-::: TOTAL RECEIVED BY: \.~ I J ,p'/!h.~~ ~ ~ I -r:..;e-tvrp? . 2: 00 \~ +'000 not included) $ 40.00 $ 40.00 $ 20.00 $ 36.00 ~ ~~ I~;: -~~ f . ~1 ~~;~ .. .. JOB NO. '1:1.0701 CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE WORKSHEET (PROFESSIONAL OFFICES & INDUSTRIAL) NAME OR COMPANY: ~ 'De... l) Ut-l~ LOCATION: '5T2..<? MA-l t-l ,,:::>, , \,Q"2-?'=?4 \ - O~\OO DEVELOPMENT TYPE: c..c. ~ Q.oIVlf'L-E--q::. U::~S~ c,.PA-c..~ BUILDING SIZE: LOT SIZE SQ, Ft. 1. STORM DRAINAGE , IMPERVIOUS SQ, FT. 0.5 x ~ X $0.186 PER SQ, FT,$ ~ (See Reverse For Runoff Coefficients If Actual Imperv. Area Is Unknown) 2. SANITARY SEWER-CITY NO. OF PFU'S 0.5 X ~ X $38,55 PER PFU (See Reverse To Determine Total PFU'S) }-~ 3. TRANSPORTATION NO OF UNITS X TRIP RATE X COST PER TRIP 0.5 X X X $388.61 $ -e- 0.5 X X X $388.61 $ $ 0.5 X X X $388.61 (See Attachment C To Determine Trip Rates) TOgL-CiT" SOC ~. $,.-z. l-,t - 'Zroz So ~ --.'-..- s~ 4. ADMINISTRATIVE FEES SUBTOTAL (ADD ITEMS 1,2, & 3) I. s1-1v 'If '7,~ 3ASE C~~RG~ (S05~OT~L A5JV~) '-' ,.:- .", . \,)J 5. SANITARY SEWER-MWMC NO. OF PFU'S \ I x $13.25 PER PFU + $10 MWHC AOf1IN. FEE S IS;' '2- (Use PFU Tot~l From It~m 2 AboV2) MWMC CREDIT IF APPLICABLE (SEE REVERSE) Ie::::' r :B. L vk.. "5/W/ 'h. , 'lfi p Burd i ck SDC Coordinator S TOTAL-HWHC SDC S ISS ,"" TOTAL SDC $ ~ t(-IS ~ ~ FIXTURE UNIT CALCU~" TABLE: Number of New Fixture.Wquivalent = Fixture Units (NOTE: For remodels, calculate only the NET add'lrional fixtures) NUMBER OF UNIT FIXTURE FIXTURE TYPE NEW FIXTURES EQUIVALENT UNITS '" 2 1 2 3 6 2 6 6 1 3 2 1 /Head 2 2 1 6 4 :z.. Bathtub..................................................................... . Drinking Fountain..................................................... Floor Drain.... ........................ ........... ......................... Interceptors For Grease/Oil/Soiids/Etc................. Interceptors For Sand/Auto Wash/Etc.................. Laundry Tub /Clotheswasher................................... Clotheswasher - 3 Or More..................................... Mobile Home Park Trap (1 Per Trailer).................. Receptor For Refrigerator jWater Station/Etc........ Receptor For Commercial Sink/Dishwasher /Etc.. Shower, Single StaIL.......................:......<................. Shower, Gang.......................................................... Sink, Bar, Commercial............................................. Urinal, StalljWall....................................................... Wash Basin/Lavatory, Single.................................. Water Closet, Pubiic Installation............................. Water Closet, Private............................................... Miscellaneous: '" c... TOTAL FIXTURE UNITS 1\ CREDIT CALCULATION TABLE: calculate credits separates. I I Based on assessed value. If improvements occurred after annexation date in table, Year Annexed Rate per $1,000 Assessed Value Year Annexed Rate per $1,000 Assessed Value 1932 $2.66 2.64 2.53 2.41 2.19 2.04 1985 1986 1987 1988 1989 1990 $1.69 1.35 1.15 0.92 0.59 0.23 .1 ) ~ 1979 or before .,1980 1981 1983 1984 Improvement (if after annexation date) X $. (Rate X Assessed Value) X $ = (Rate X Assessed Value) CREDIT TOTAL = s Credit for Parcel or Land Only If Appiicable RUNOFF COEFFICIENTS FOR STORM DRAINAGE Resid entiaL...................................................... 0.4 CommerciaL............................................. ......- 0.9 I nd uslriaL.......................................................... 0.45 GovernmentaL......... ... ... ... ........ ........... ......... .... 0.5 IMPERVIOUS AREA = TOTAL LOT SIZE X RUNOFF COEFFICIENT