Loading...
HomeMy WebLinkAboutSpecial Inspection Fire Damage Report 1978-11-10 ..,,____.~_o;. . . ...~,... .. ,,,, , . CITY OF SPRINGFIELD SPRINGFIELD, OREGON 97477 PUBLIC WORKS November 10, 1978 346 MAIN STREET 726,3753 ,Mr. Jerry L. Harrison c/o D.J. 's Markets P.O. Box 10397 EUgene, Oregon 97440 * RE: Fire Damage Inspection Of Market Building at 5705 Main St., Springfield, Oregon Dear Mr. Harrison, " On Friday, October 27, 1978, Dan Smith and I met with you and your partner, Dennis Atkinson, at the site of your fire damaged market to p~rform a struc- tural inspection, The nature of this i-nspection"at your request, was to inform you of Building Department Requirements with regard to reconstruction and possible reuse of part of the fire damaged structure. The following items were determined during this inspection: (A) Demolish and remove the remaining roof structure and supporting pipe columns as soon as possible, since they are not suitable for reuse and pose a potential hazard in their current condition. (B) In o~r opinion, the existing concrete block walls could be reused, but would require the removal and reconstruction of the top, five block courses to'the point of bearing for the beams supporting the roof. " (C) Our'observation indicates that the temperatures reached during the fire were not sufficient i'n most of the building to have caused permanent damage to the existing reinforced concrete block walls. We recommend, however, that an independent ,testing agency be employed 'to test a few representative samples of the existing concrete block and it's rein- forcing to verify that the structural integrity of the walls, was not , impaired as a result of the fire. All electrical wiring must be replaced. We discussed th~'~ossible , reuse of the existing electrical raceway system under the concrete slab. At our request, J. R. Matteson, Electrical Inspector for the City of Springfield, also visited the site on November 6, 1978. It was his determination that we could not allow reU5e of any existing electrical raceway without its being exposed for visual inspection. -'''"'''.->....".........,._- .:..-.. ..~,. ':1 "t " " , - ';'.' ''. ...;:1. . .-' .: :~:y . ..' '1"; . , . . ""\ :~, ,"':-,\' ~:~r ".1.; , .." ~i~:.~.:: .'\~~;,~' :.- <::(,'. ._, ~.. I " . ,. ~ .' '. ',>, r', " ' " .........., , ':~ ...... .... .... , -, \\,' . . November 13, 1978 Mr. Jerry L. Ilarrison Page 2 If you have any questions regarding these items, or wish to request any further'service from us, please contact me. Sincerely, ~v~ LV_~ Lorne W. Pleger Plans Examiner & St~uctural Inspector LWP: d r