Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2009-1-8 ePRfNOFlELO r.. ..;:..~.'~'-... . .1. Me...., ..... .'. I City of Springfield Building Permit & Inspection Summary . 1/8/2009 6: 18:23PM Job #: COM2008-01498 225 Fifth Street 5'<11-726-3753 Phone 541-726-3676 Fax Job Address: 4181 EST Springfield Scope of Work: Tenant Infill Description of Work: Change of use from B to E - OK to accept one-half of plan review payment per Robert C. 11-18-2008. Project Status: Issued Name Owner & Contractor(s) Address 1600 VALLEY RIVER DR 4284 W 7TH AVE 1580 VALLEY RIVER DR S ARC AffOLTER WEST AND JONES CON ESSEX GENERAL CONSTRUCTION OWN LINCOLN CAPITAL II LLC Valuation of Proiect Occuoancv Construction Tvoe Cost Per So Ft So Ftl! Schools $ 84.00 VN 3,000.00 Descriotion Fees Paid Date Paid Amount Paid Plan Review CommllndlPublic Plan Review CommllndlPublic Building Permit Plan Review Fire & Life Safety + 5% Technology Fee + 12% State Surcharge + 10% Administrative Fee Total Amount Paid $391.93 $391.92 $1,205.93 $482.37 $60.30 $144.71 $120.59 $2,797.75 11/18/2008 12/17/2008 12/17/2008 12/17/2008 12/17/2008 12/17/2008 12/17/2008 Plans Reviewed Deoartment City. State. ZiD EUGENE OR 97401 EUGENE OR 97402 EUGENE . OR 97401 Phon~ 541-342-4509 .. Date Valuation Calculated Staff $252,000.00 2008/11/10 NJM $252,000.00 Receiot # 2200800000000001652 1200800000000001228 1200800000000001228 1200800000000001228 1200800000000001228 1200800000000001228 1200800000000001228 , 10/02/2008 Received Due Date Comoleted Result Reviewer Comments Structural Review 10/02/2008 WE RWC Initial Review Plannin~ Review 11/19/2008 12/02/2008 11/24/2008 APP 12/02/2008 APP LLH EMM Structural Review 11/24/2008 12/12/2008 WE RWC I of3 called Kent Affolter about new plans for 1-4 use. 10/2/08 Revised drawings This use has been approved by planning for daycare and preschool instruction and specifically prohibits elementary school instruction at this location without a . discretionary use/site plan review and approval. Revised Drawings Structural plan review, planning review complete. Waitting for fire to approval " c 225 Fifth Street 541-726-3753 Phone 541-726-3676 Fax . Project Status: Issued Fire Department Review 12/1612008 'nsoections Fire Department Final Fence Rough Electric Final Electric Final Bnilding Site Inspection Framing Inspection Site Inspection Site Inspection Final Building' Site Inspection o."J.,..,"'.,,'.'.-'....l.. City of Springfield Buiiding Permit & Inspection Summary 1/812009. 6: 18:23PM Job #: COM2008-01498 . ...., Job Address: 4181 EST Scope of Work: Tenant InfiIl Description of Work: Change of use from B to E - OK to accept one-half of plan review payment per Robert c.. 11-18-2008. 12/16/2008 APP GRG Insoections Condncted Comments Date oWner has children pressent at location without change of use, On October 7 and 9th inspections. 10/0612008 10/1312008 Owner is using building for adult care(I-4) and day care( E) without having a change off use in place. Owner was given until October 13 to have plans in City of Springfield office. met contractor about plan review issues . 12/2312008 01/05/2009 . 2 of3 Springfield Plans Review: Change of occupancy classification and use for west side of building (building divided by 2 hour fire wall) from B to E (day care). Job #COM2008-01498. Construction Type: V-B. Square Footages: Change of use area-9,155 sq. ft. Total Building including east side bingo assembly area-I 7 ,260. West side day care occupant load: 215. 1'.' " Fire and Life Safety evacuation plans submitted per 2007 Springfield Fire Code 404 and 405. Fire alarm contractor shall provide as-built drawings for any:modifications to the fire alarm system. Result Insoector , " '~'J, - 10 RWC BWOP RWC NR 10 RWC RC ~r. ~"- ,r' ,,;. i 1 a....~:'!~~.~9 .....'1,. 'Wir" , , , . ...~... ' ''IlQ' I ~^;-'. .".. . . , m' 225 Fifth Street 541-726-3753 Phone 541-726-3676 Fax Project Status: Issued Framing Inspection City of Springfield . Building Permit & Inspection Summary 1/8/2009 6:18:23PM Job #: COM2008-01498 Job Address: 4181 E ST Scope of Work: Tenant 1nfill Description of Work: Change of use from B to E - OK to accept one-half of plan review payment per Robert C. 11-18-2008. 01/07/2009 met contractor about plan review comments 1/2 work complete missing 1) ADA access to all require~ egress doors ( greater than 1/2 inch treshhold 2) provide electrical fmal 3) provide fIre construction fInal ( including pull stations, strobes, fIre extringishers ) 4) provide egress lighting report 5) Evacuation plan to be available in the work place for refemce abd review by employees and copies shall be furnished to the fIre code official fore review upon request (OFC 404.5) Note: Egress at south end of day care not a required egress. . Contractor to remove face plate and provide a blanked off exii with emerancy lighting still working. ADA ramp ast this door does not meet code do to slope of . ramp. 30f3 Springfield. 10 RWC , 1 i