HomeMy WebLinkAboutMiscellaneous Correspondence 1985-10-18 -- . . ~ ;---' SPRINGFIELD CITY OF SPRINGFIELD Office of Community & Economic Development Planning and Development Department October lB.. 1985 Ms. Bessie Noble 18138 Bancroft Avenue. Monte Sereno, California 95030 Dear Ms. Noble: *~ . r-~", , ! At the request of r~s. Roxi e Cue 11 ar, acting as agent in your behalf, the Springfield Building Safety Oivision conducted an occupancy inspection of the residential structure located at 5940 Main Street, Springfield, Oregon. The purpose of the inspection was to determine the suitability of the building for use as commercial offices. The above proposed use of the structure will categorize it as a B-2 occupancy. The following items must be installed, repaired, modified, or replaced in order to conform to applicable codes for that occupancy. City Zoning Ordinance Provide a minimum of four off street paved parking spaces, with a mintmum of five feet landscaped buffer between the parking and the adjacent residential property. A site plan showing parking and landscaping should be submitted to this office for review and approval by the Development Coordination Review Board. Structural Soecialty Code and Fire and Life Safety Code 1. The elevation of the floor or landing on both sides of the exterior doorways must be no more than half an inch below the level of the threshold. Modify existing doorways to meet this requirement. 2. Locks on exit doors must allow the doors to be opened from the inside without the use of a key or any special knowledge or effort. Revise the existing double keyed locks to comply with this requirement. 3. All glazed panels in doors and within twelve inches of doors must be of a safety glazing material, identified by a label attached thereto. Replace all non-complying glazing to meet this requirement. 225 North 5th Street . Springfield, Oregon 97477 . 503/726-3753 '- . . ,;/ Ms. Bessie Noble October 18, 1985 Page Two 4. Provide a fire extinguisher with a mlnlmum rating of 2A (five pound type is recommended), mounted with the top at a height of three to five feet above the floor in a conspicuous location and readily available. 5. The roof visibly. required. P1umbinq Specialty Code structure at the east wing of the building sags Reinforcement or bracing of the roof structure is 6. Replace the deteriorated water closet. 7. Relocate exteri or of the than six pipe water heater relief valve discharge to the using three quarters of an inch pipe. The terminal end pipe shall be turned down and shall terminate no closer inches above the ground. Electrical Safety Specialty Code 8. Install a wall switch for the bathroom light. In addition to the above requirements, the following measures are recommended: 1. Di sconnected roof dra i nage has started eros i on of soi 1 adj acent to the structure. Gutters and downspouts which will drain away from the building are recommended to alleviate this problem. 2. The existing chimney was constructed for the use of oil or gas fired appliances only. It is unsafe for use with a woodstove, for which it has apparently been set up. Removal of the .obso1ete chi~ney is recommended. Building permits are required for approval of the door and landing and roof modifications, as well as the electrical and plplng installations. The required permits and inspections can be obtained from this office. Please note that the electrical work must be done by an electrical contractor, licensed in Oregon for such work. '-. . . ,/' Ms. Bessie Noble October 18, 1985 Page Three Please direct all inqulrles to the Springfield Building Safety Division at 726-3753. Sincerely, 1iJ4~ Don Moo re Structural Inspector cc: Roxie Cuellar 5925 Main Street Springfield, Oregon 97478 #574