Loading...
HomeMy WebLinkAboutPermit Building 1991-4-26 .' 225 Fifth Street, Springfield, Oregon 97477 ~ . JOB NUMBER 90-10-170 Cill()~ I . . COMMERCIAL/lNDUSTRIAL. PERMIT APPLICATION INSPECTION LINE: 726,3769 OFFICE: 726,3759 LOCATION OF PROPOSED WORK: S.W. Corner Main St. & S. 58th. St. 57.-?~ MAIN 57. ASSESSORS MAP' 17-02-33-44- TL 800,900,1302,1303,1304, & 1305 17_n?_ ~~-A.l TT. ~l no. ~,oo. 1100. 14()(). ~. ~5CO Albertsons Inc. TAX LOT' CITY: STAT~' ID ZIP' . 83726 .Jt- OWNER: ADDREC'" 250 Parkcenter Blvd. Boise PHONE: 208-385-6204' DESCRIPTION OF WORt<' Construct a new market buildina. NEW X REMODEL ADDITION DEMOLISH OTHER VALUE: NAME ADDRESS ARCHITECT' EHMANN-KLAS ASSOCIATES, P.C. 6775 S.W. Illth Ave. Beav., CONST, CO NT RACTO R # . PHONEPAlXt;;'2';;:''ll~ OR 97005 644-4222 CONTRACTOR'S NAME ADDRESS. (Contract9~ not selected at this time) GENERAL: .2Y/P'/~/ LLPH-5"/. . /L) ~ fjvR~. L:-""'a:;:~ .- . / . - / , PLUMBING: EXPIRES PHONE =<~.y~r . -::J-:<>-:;>-92 - t.;J!?~~/ "'/7 - " MECHANICA' . ELECTRICAl' I PLUMBING I MECHANICAL I I NO, I FEE CHARGE I IIIn ~~~ ,........o.Dnl= I I "13 Single Fixture II) 99~,""'1 0 Ii,....,",,:~_"'_, ;,..,.. -I .., /sA'. ......1 < 100,000 BTUs -1.c.Yo ~ "'3 t;;., 1 Relocated Bldg, I I ~ Furnace/burner & ve'nt . 1. 5'c:> :2 .o?5"0 1 (new lix. addtll >10~OOO BTUs 1670' Water Service I'?O, -- 1 I /i!; C;-':'''~"v...~?.:lQ'J // "'''1 It. ~ nr rllacP :mrl v:e 1675' Sanitary Sewer 19.17. obI> I 3. Suspended wall or floor ~,-'" 18. _""I It. mounted unit heater ~.2..y1) 'I Storm Sewer ~'~5. <>0 I Appliance Vent I It. separate I / I I 3 Stationary evap. ;(~ I:? So I Backflow Device /.p,"'" cooler ..:&'-/.t-:t /-t!:.L>> 1 / 1 6ReA!><S //,I r.5z1 eEl' r,p~ 1.17 . ,::u> I I~ Vent Fan/Single "2 ~, 0""1 duct I I I ~ Vent System apart t/50 /.!fJ. =' 1 from AC or htg. I "I 1 2 Mechanical exhaust 'tSt::> ~.at1> I hood and duct I I II GIfl5 .17~re::c=-r5 .()-o S:s~1 I I Permit Issuance $10,00 I I TOTAL PERMIT r/56~a<>1 TOTAL PERMIT /55'.5"(/ I - OFFICE USE - HANDiCAP ACCESS: QUAD AREA' LAN D USE: FLOOD PLAIN' ZONING: Cc:::. # OF BLDGc, OCCY GROUP: _8~Z # OF STORIES:_I'7'-~22. / # OF UNIT:'" CONSTR, TYPE: '? IY,. 5)'..2< HEAT SOURCE: r:::: ~c LIGHTING POWER BUDGET: WATER HEATER' SQ, FTG MAIN SQ. FT. 1/"1-t:J :5'0 $/SQ, FT, VALUE ~~~~~~ --.'-"'-- ........--...... ._-~-- X SQ. FTG ACCESC:' -- -- --X SQ, FTG OTHER ?/7'otf: kp.&>tI'~. X : ~q7 ~<;I - 2,'~;~7~t' . Estimated TDTAL VALUE OF PROJECT 1.488.~gQ PLA~LC~WJ~;.J7f:!-~~_AC+J;'j.t'7.:.z~r.>J/A~r> ~;Z~ ,....BY L~..k.~.....-. I BUILDING PERMIT 15% State Surcharae I MECHANICAL 5% State Surcharae PAVING ~tJ~~.?O H)~, 1'15' 16'5". 5'.0 7. 7t> It:. '3tJ>.- I PLUMBING 5% State SurcharQe FENCE VALUE $ SIDEWALK /056' 0:" 0 DEMOLITION '28. '2S' Az,fN-r/""'NA~ ~ac IEEE I SUBTOTAL FT. .w 5~~~,G PERMITS _1 SYSTEMS FT, p.w. ;P~<P.JG.?7f DEVELOPMENT j P~"p.JC'/ A'ofV/c~ , 26<::), '13 I I Ig,5: ij~ Y6 I CURBCUT .' TOTAL PERMIT FEES I, EXCLUDING ELECTRICAl ' L/->,'_ ~ '....o:l>. 74:/.;;>7;7_. . REQUIRED INSPECTIONS ~ . i It is the responsibility of the permit holder to see that all Inspections are made at the proper time. To request an inspection, call 726.3769 (recorder), state your City designated job number, job address, type of inspection requested and when you will be ready for inspection. Requests received before 7:00 a,m. will be made the same working day, requests made after 7:00 a.m. will be made the following work day, SITE INSPECTION: To be made after excavation, but. prior to setup of forms. x UNDERSLAB PLUMBING, ELECTRICAL & MECHANICAL: To be made before any work is covered. /' ROUGH PLUMBING, ELECTRICAL & MECHANICAL: No work is to be covered until these inspections have been made and approved. x PAVING: After gravel is in place but prior to placing asphalt or concrete. y' FOOTINGS & FOUNDATIONS: To be made after trenches are excavated and forms are erected, all steel in place, but prior to placing concrete. x ATTIC\'liRAFT STOPij)& CURTAIN WALLS SPECIAL INSPECTIONS: In accordance Section 306 of the State Specialty Code a special inspector shall be employed by the Ownerl Contractor during construction of the following work. A copy of the special testing reports shall be furnished to the Building Division. x,: STRUCTURAL CONCRETE: In excess of 2500 PS,I. (306 a,l) )< CONCRETE SLAB: To be made after all Inslab building service equipment, conduit, piping, accessories and other ancillary equipment items are in place but before any concrete is placed. FIREPLACE: Prior to placing facing materials and before framing inspection. ^ FRAMING: To be made after the roof, all framing, fire blocking and bracing are in place and all pipes, chimneys and vents are complete and the rough electrical, plumbing and mechanical are approved. x STRUCTURAL WELDS: Performed on the job, (2722 f) /- UNDERGROUND: Plumbing, electrical, gas, sanitary sewer, storm sewer, water and drainage lines. To be made prior to covering or filling trenches. )( INSULATION & VAPOR BARRIER:, To be made after all insulation and required vapor barriers are in place but before any lath or gypsum board Interior wall covering is applied, - x HIGH STRENGTH BOLTING: During all bolt installation and tightening operations. (306 a,6) UNDERFLOOR: Plumbing, electrical, mechanical. To be made prior to installa'tion of floor insulation, decking or floor sheathing, POST & BEAM: To be made prior to installation of floor Insulation, decking or floor sheathing. FLOOR INSULATION & VAPOR BARRIERS: To be made prior to installation of decking or floor sheathing. ( FIRE & SEPARATION WALL: Located and constructed according to plans. x LATH AND/OR GYPSUM BOARD: To be made after all lathing and gypsum board, interior and exterior, is In place but before any plastering Is applied or before gypsum board joints and fasteners are taped and finished. SPRAYED ON FIREPROOFING: U,B,C, Standards 43-8. SPECIAL GRADING, EXCAVATION AND FILLING: During earthwork, (306 a,11 & Chapter 29) GLU.LAM BEAMS: Inspection Certificate by an approved agency, furnished to the City's Building Division before beams are placed, (250' U,BC, STDS, 25,10,11), STRUCTURAL MASONRY: (306 a,7) /N///ID.E'b IN :5'~HAI?.i) -?veL.t'';:___//'AP~'''''/Y-?F~ ,- 7J:/,p./~~T _ ~ '"In addition to the inspec. tions specified, the Building Official may make or require CURB AND APPROACH other inspections of any ROOF SHEATHING AND ~ APRONS: After forms are construction work to ensure NAILING: Prior to installing erected but prior to placing compliance with the Building, any roof covering. concrete. City or Development Code. -7- FINAL --;LUM~NG ------ --- J.' - SITE --;;LAN :EVIEW ~OA:D: M:;-b:-;:qUested-2--:;~:-i~::::- of the date you wish inspection. All project conditions such as landscaping, parking lot striping, etc. must be completed before requesting this Inspection. )( MASONRY: Steel location, bond beams grouting or verticals in accordance with UBC 2415, x )< )( f FINAL ELECTRICAL FINAL MECHANICAL FINAL FIRE DEPARTMENT ADDITIONAL COMMENTS: SIDEWALK & DRIVEWAY: Required for all concrete paving within street right of way, to be made after all excavating complete and form work and sub-base material In place. )( FINAL BUILDING: Requested after the final plumbing, electrical, mechanical and Fire Department inspections are, made and approved. No occupancy of the premises can be made until a Certificate of Occupancy has been issued by the Building Division and posted on the premises. PLANS REVIEWED BY ~~-~ DATE V-<~'9/ - tY/~ -.. /' r At:::K', -4j;",/,b -91 By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that allinformatton herein is true and correct, and I further certify that 'any and all work performed shall be done in accordance with the Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Bullding.Safety Division. I further certify that only contractors and employees who are in compliance with OAS 701.055 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that project address Is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. Signatur~~~~ ~.. Oate_4--/CS/g)'- VALIDATION: AM~ECEIVEO: -4-'!; '?:?S. -:s ? RECEIPT': -:::;?o/3Af: DATE PAID: ~'Y."7t'_ , RECEIVED BY: ,..,....-~. .-{~ /--"" , '//- - 1 ___;;- ,... ~ Metropolitan Wastewater, Management Commission . . COMMISSION MEMBERS Rob Bennell-Eugene Councilperson Steve Dully-Eugene lay Representative Scolt Engstrom-Springlield Lay Representative Chris Larson-Springfield Councilperson Chris Matson-lane County Lay Representative Jerry Rust-Lane County Commissioner Mark Westling-Eugene lay Represent21ive FIFTH AND A STREETS - SPRINGFIELD CITY HALL - SPRINGFIELD, OREGON 97477 TELEPHONE (503) 747,4551 Building Address: 575"~ M.4/-<:7 --5r .. '?; ,( /7-.t')';l-~~-<fI' -. ~.T"",,,,,,~~'~j;V.o1'-~Te>~ Reference Number: (7-02-'3 3~7f7" Tax Cot -Number:2=1"~ ./! mK<6C, .2 0."" ,IY7/N"'...... 1"'~/'/7'/""''''7 Owner: /T L"f3~T?p~ ~L . Address: 2'i"?' P/???KCF_~ j5>.c..V,T;) City: fS?~~~ State: M~MC CONNECTION CHARGE /2/. Residential F.ee ($222,00) x Commercial Fee (new non-residential development/ remodel) Total fixture unit charge (see reverse of this form) , . SUBTOTAL Credit Due (see reverse.of this form) TOTAL M~MC CHARGE Date Received: h-/rr-'7/ --::<0 ~ ;c:;: Building Job Recei ved By: Receipt Number: .' Phone Number: C?"'8)3>C'5'.~'7 . Zip:~372h $ $ ~5?>O. 7-; $ <$ C:;O I. ~ :3 > $ /92 q. "'3 7 ,:2~~4~ N~C 9/o:::s'?/ . ~ . . .. Fixture Unit Calculation Table: Number of ney fixtures multiplied by unit equivalents, NOTE: For remodels, calculate only the NET additional fixtures, Fixture Type Jf'M Ba t h tub, , , . , , , , , , , , , , , , , , " , , , , , , . , , , , . , , , . Drinking fountain, ."",.."" """""" Floor drain.""".."...""".",.".,.,. . I~terceptors for grease/oil/solids/etc,~:, "Intercep'tors {or sandhiuto yash/etc" '.,... Laundry tublclothes "'.asher,:""."." ,;,,- Clothes yasher (3 or.more):,',........,..,:, Mobile home park trap (1 per M,H,~"."".' Receptor for refrig/yater station/etc,.,., R~~eptor for Commer sink/dishysh~/etc:,:,' Shoyer, single stall""""""".".",. .Shoyer, gang (per head),.."""",.",,:. Sink, bar, commerciaL"",,""",.,"'" Sink, commercial/industrial/etc.,.,""'" Urnial, stallNall"",,"""'.""".'" Vash basinllavatory, single""",.""", Vater closet, public installation"".,'" Vater closel, private..""""""""". Miscellaneous: """"" # of Fixtures Unit Equivalents Fixture Units 2- " 6'~ I 2 1 2 3 6 2 6 6 1 3 2 1 2 3 2 1 6 4 24 :z. _/ '2. 12. '-;'2.0 'Z. It>l, ~ :' '. . ..... ......- \ /0 .'. JoZ) .., / /2. :? ~ . ' \':..-' Total Units: j"l/ x $13,25 each = Total Charge: $'2?-=3&'.75"" Total fixture uni ts J9/ 'Credit' Calculation Table: Based on total value of property at time of permit application. Year 'Annexed to the city '. -" . 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1?60 '~. . .::;:-..... '.,. " ". Cred it :2, C:;;/iG Rate " , , Credit per $1,000 assessed value . > $2.66 $2.64 $2,53 $2.41 $2.19 $2.04 $1. 69 -,$1.35 $1.15 $0.92 $0,59 $0,23 x $ '22t2:. t95?;/ Assessed Value = $ h c/ / . 3fb Total Credit