HomeMy WebLinkAboutNotes, Work PLANNER 9/4/2007
,-
As O'F "lIdo,
,
"
EMBASSY SUITES SITE PLAN REVIEW
DRC2006-00062
TENT A TIVE APPROVAL ISSUED OCTOBER 2, 2006
CONDITIONS OF APPROVAL:
/ I,' Prier te approval .of the Final Site Plan, the site plan shall be revised te pre vide fer a water system te serve
the site that is censistent with SUB Water Divisien standards,
l( 2, All new easements shall be recerded and evidence thereef provided te the City, The Final Site Plan shall
shew the lecatien .of utility easements,
) 3,' All utility lines te serve the develepment site shall be placed undergreund,
X 6,
),
4,
Prier te appreval .of the Final Site Plan, the site plan shall be revised te shew the recycle/refuse area
plumbed t6 the sanitary sewer system,
A
Prier te approval .of the Final Site Plan, the site plan shall be revised te shew' the undergreund parking
garage drainage system plumbed t.o pass threugh an .oil/water separater and then inte the sanitary sewer
system,
J7,
Prier te appreval .of the Final Site Plan, the applicant shall provide written verificatien frem Oregen
Department .of Transpertatien (ODOT) cenfirming that vegetative swale #1 can dis~harge inte the existing
ODOT drainage ditch .outside the seuth preperty line,
Prier te approval .of the Final Site Plan, the applicant shall revise the site plan te r;;meve the existing area
drain in propesed drainage basin #2, '
j 8,
Prier te approval .of the Final Site Plan, the applicant shall revise the site plan te ;indicate the size .of the
existing sanitary and stenn sewer lines beth en and .off the site,
Prier te appreval .of the Final Site Plan, the applicant shall provide a mainten~nce plan that includes
provisiens fer ensuring leng-tenn functienality .of the three propesed vegetative swales,
'4.. 0, Prier te approval .of the Final Site Plan, the applic~nt shall revise the site plan te previde an appropriate seed
, mix fer the three private vegetative water quality swales en the site, The seed mix and applicatien rate shall
be described en the site landscaping plans, No., 'Su-6....1-r~
J9,
j 1.1, Prier te issuance .of Final Occupancy fer the hetel building, the 'propesed private vegetative water quality
swales shall be fully vegetated with all species established te ensure a fully functiening water quality
system, Alternatively, if thiscenditien cannet be met, the applicant shall provide and maintain additienal
interim erosien centrol measures acceptable te the Public Werks Department that will suffice until the
grassy swale vegetatien becemes fully established, '
) 12,' Prier te appreval .of the Final Site Plan, the applicant sh~ll provide fer emergency access te the west side .of
the hetel building'by way .of a jeint use easement recerded with the adjacent property, .or an alternate access
scheme acceptable t.o the Fire Marshal. Ni> !luILl> ,I'i Go PLA~.s
)13, Prier te approval .of the Final Site Plan, the applicant shall provide written cenfimiatien frem the adjacent
landewner allewing fer jeint use .of the private fire hydrant. Alternatively, the plans shall be revised te
shew the lecatien .of a new fire hydrant at a lecatien acceptable te the Fire Marshal. '
Date ~6ce,ived:
Planner: AL
1 /;;/ ;lJXl7
/ /
/ 14, Prior to approval of the Final Site Plan, the site plan shall be revised to provide for st~ndpipe connections at
appropriate locations on the building exterior.
115, Prior to issuance of Final Occupancy for the hotel building, "No Parking - Fire Lane" signage shall be
installed around the ladder truck access areas on the north sIde of the bUlldmg, ' "
J 16, Prior to approval of the Final Site Plan, 'the site plan shall be revised to show an acce~table Fire Department
connection at the northwest comer of the building,
/17, Immediate access and at least three (3) feet of clear space in all directions shall be"maintained for all fire
hyd;ants a~d Fire Department connections in accordance with SFC,50S,5,5 andSFC 912.3, '
/1S, Prior to approval of the Final Site Plan, th~ site plan shall be revised to provide for appropriate
decommissioning and/or removal of the existing gas lme,
) 19, The Final Site Plan shall indicate 55 standard, 7 compact and one handicap parking space's for the
underground parking garage on the Site Data table shown on Sheet SP-l,
j 20, On the Final Site Plan, the compact parking spaces shall be appro~riately identified by signage or painting
in accordance with SDC 31,190(7), '
j 21. The Final Site Plan shall provide for additional bumper overhang or wheel bumpersi'for tlie four parking lot
islands that contain parking spaces, '
)22, The Fin'al Site Plan shall show the location and typ~ of handicap accessible ramps s';rving the site in
, accordance with the options shown on Sheet DT -1,
X 23, Prior to approval of the Final Site Plan, the site landscaping plans shall be revised to speCify whether the
, existing street ,trees 'along Gateway Street are to be retained or replaced, 'NuT ~M I T"T-1::t:>
><.. 24, Prior to approval of the Final Site Plan, tlie site landscaping plans and plant legend shall be revised to'
accurately account for the quantities of trees and shrubs proposed to be planted on the site, ~ T l5L<./3M '. '-e b
'7 25, Prior to issuance of Final Occupancy ,for the hotel building, the applicant shall, receive approval of a
Drinking Water Protection Overlay District application for the proposed development pursuant to Planning,
Action DRC2006-00069, ,:
'.>i. -26, Prior to approval of the Final Site Plan, a joint use easement for cross-access between: the subject site and ,
Tax Lot 1400 shall be recorded and evidence thereof provided to the City b<J\ "T ~5N rs '" 0 ,..
"$&.A..8.r'1. .~
/ 27, Prior to approval of the Final Site Plan, a joint use easement for cross-access from the subject site onto Tax
Lot 1700 'shall be recorded and evidence thereof provided to the City, 'DE:L-c ,=,-,
,/ 2S, Prior to issuance of an LDAP for the site, a Tree Felling Permit shall be issued pursuant to Planning Action
DRC2006-0006S,
r;lateJ Recei~ed,: q ~ ~7
Pl.anner: AL ,0