Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2009-4-27 t ft~. '/Tiformation ~~.,:r:..lToBuild On olIfIIgjIna_ ...;., . ~ . ........_ 'Client: Address: Springfield School District 525 Mill Street Springfield, OR 97477 Placement Data: concrete seat walls between areas 1 &.2 and 3 & 4 Location Sampled At: same as above Dale Cast: Ticket No.; 3353557 03127109 Date Rec'd: l~i:4~~:15200 Weather: ___--1._ 03130109 Clear Desiqn Strenqth (psi): = - -- - COMPRESSION REPORT Project No.: 722-80173-203 Proj, Name: Thurston Elementary School Location: 7345 ThurstDn Road Springfield, Oregon ,Material: Concrete Slump (in.): ASTM C143 Max. Aggr: Size: Air Content: ASTM C231 Air Temperature"(F): .Material Temp. (F): ASTM C1064 Max Temp (F): ,Min Temp (Fl: ______ Specimen Size: Unit Weight (pet): ASTM C138 Time Cast: 8:30 AM Additives: Hot Water Results Reported To: Contractor Yatdage Load: 1 Total: 20 Supplier: Knife River required 4,000 . Compressive Strength Data ASTM C39 t>1~~ed 4,000 Cylinder No. Test Date - Age(days) FleldCur~ (days) 09-0829 I 41312009 7 3 09-0830 I 412412009 28 3 09-0831 I 4/24/2009 28 3 09-0832 I Hold H .I 3 _ H 1-_Gon~Jb:~_lh _~nds), 2-.: ConeNerticaICracks.(oneend)_._ Remarks: c: SPRINGFIELD OFFICE 1040 - A Shelley Street Springfield, Oregon 97477 (541)746-9649 - (541)746-7163 fax ~~~~o.: C~r;~3'J001 CCB#176269 P:O. No.: P0272-334-0809 Cast By: Raymond Aliperti Field Test Data 5" 314" 430 67" 4x8 Curing Conditions: 3 day F .C. remainder A~TM lab Cure Diameter or Cross Sect Area Cylinder WT. Compo Stren!:lth Capping Method Dimensions Max. load (ibs.) Fracture Type.*" Test Time (days) (inches) (s.i.) (Ibs.) (psi) C617-03 C1231-0J 4 4.01 12.63 8.1 43,435 3,440 8:34 AM X 25 4.01 12.63 8.4 62,860 4,980 2 3:17 PM X 25 4.00 12.57 8.4 62,590 4,980 2 3:20 PM X H 3,,:-'Columnar- 4 -' Diagonal ,wIno crackingal ends,-. 5 -'Side fractures(al top'oi'bottom) KPFF " ugo.costa@kpff.com Hyland Construction - markb@jhconst.com Milstead & Associates - angus@milstead.us Mahlum - rberndt@mahlum.com Robertson/Shenwood & Architects - dguadagni@robertsonshenwood.com Springfield School District - jsaracen@sps.lane.edu Yolanda Bird - yolanda.bird@sps.lane.edu City of Springfield 6 --Top fractures (same'8s\#5'but end of cylinder is pointed) Respectfully Submitted, ~1}&.(5es Industries, Inc Raymond Aliperti Project Manager 7/-ns REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY BY ANY MEANS EXCEPT IN FULL, IS PROHIBITED WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL,SERVICE INDUSTRIES. l.. ~ .ZIiifOrmation ,,~. .To Build On Engineering. Consulting . Testing April 24, 2009 CCB# 176269 Mr. John Saraceno Spnngfield School District 525 Mill Street Springfield, OR 97477 Subject: Final Summary Report Thurston Elementary School 7345 Thurston Road Springfield, OR 97478 Project Number: 722-80173-20i'- _ \ Building Permit No..' COM2008,00437 ~p"o NO.: 272-334:0809' -~ ~, Dear Me. Saraceno: Professional Service Industries, Inc. (PSI) is writing this letter to document that, ih accordance with Section 1701 of the State Building Code, representative{s) from our firm have performed special inspection during construction for the above listed project . Our project file(s) indicate that PSI Special Inspection(s) activities listed below were conducted as scheduled from March 24, 2008 through April 17, 2009. This letter represents a.,summary of work observed and reported by PSI representative(s) and the resolution of any documented noncompliance. .. Soils Observation . Reinforced Concrete . Structural Fill . Structural Welding . Field Density Testing . High Strength Bolting . Reinforcing Steel . Epo~y Anchor Bolts To the besl'of our knowledge, the special inspections referenced herein were performed by our firm in general accordance with the requirements, approved plans and specifications, geotechnical report prepared by PSI, provided change orders that impacted plans andlor specifications, and applicable workmanship provisions of the State Building Code and Standards. '. For specific details regarding our inspection services, please reference our previously submitted reports numbered 722-80173-1through 722-80173-206. For Soils Observation, Structural FiI.I and Field Density Testing during building pad construction please reference our previously submitted reports numbered 722- 80054-1 (March 24, 2009) through 722-80054-48 (August 4, 2009) Sincerely, t?~ess~onal S R~d~. Allpertl Project Manager cc: KPFF - ugo.costa@kpff.com Hyland Construction - markb@jhconstcom Milstead & Associates - angus@milstead.us Mahlum - rberndt@mahlum.com RobertsonlSherwood & Architects - dguadagni@robertsonsherwood.com Springfield School District - jsaracen@sps.lane.edu. Yolanda Bird - yolanda.bird@sps.lane.edu . City of Springfield If you have any questions or if we can be of further assistance, please do not hesitate to call. l)~,LM David F. Smith Branch Manager I?I::CI:- <:.1111:: /14)'0] D ~ Professional Service Industries, Inc.. 1040A Shelley St.. Springfield, OR 97477. Phone 5411746.9649. Fax 5411746-7163 - ,