HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 1997-3-24 . . . - BRAUN'. INTERTEC . Braun Interfec Corporation 2285 Nugget Way Eugene, Oregan 97403 541.746-9649 Fax: 746-7163 Engineers and Scientists Serving the Built and Natural Environments DAILY FIELD REPORT Date: March 24, 1997 Project #: EBXX-97-0099 '* Report #: E-58902 Job No. n/a Pennit No.: 961580 Weather: Clear Tested For: SI. Vincent de Paul Project: SI. Vincent de Paul Residence Job Address: 7085 Main Street Eugene, Oregon Type of Inspection: Epoxy Anchors Type of Structure: Stem wall Specific Placement Locations: Stem wall - north side of garage NOTE~ Observed the placement of epoxy anchors at the stem wall, north side of garage. Four holes were drilled (two on east side, two on west side) using a I" diameter bit. Minimum embeddment depth of 7 7/8" was verified. 7/8" diameter all thread bolts were installed using Epcon Ceramic 6 Formual in accordance with the manufacturer's directions. Prior to installation, the holes were cleaned with compressed air and a nylon wire brush. Contractor was asked to notify our office when additional servcices are needed. Inspector: Number: Raymond V. Aliperti ICBO 98554 If you should have any questions regarding this report, please call Raymond Aliperti at (541) 746-9649. Thank You. City of Springfield - Bob Barnhart / St. Vincent de Paul - Lyle Harris c: As a mutual protection to clients, the public, and ourselves, all reports are submitted as the confidential property of clients and are intended for the use of our clients only. No other person or entity may utilize the report or any portion thereof without our written authorization. c:\wp51 \reporta\insp\stv58902 .stv