DAILY FIELD REPORT
Date: March 24, 1997
Project #: EBXX-97-0099
'*
Report #: E-58902
Job No. n/a
Pennit No.: 961580
Weather: Clear
Tested For: SI. Vincent de Paul
Project: SI. Vincent de Paul Residence
Job Address: 7085 Main Street
Eugene, Oregon
Type of Inspection:
Epoxy Anchors
Type of Structure:
Stem wall
Specific Placement Locations: Stem wall - north side of garage
NOTE~
Observed the placement of epoxy anchors at the stem wall, north side of garage. Four holes were drilled
(two on east side, two on west side) using a I" diameter bit. Minimum embeddment depth of 7 7/8" was
verified. 7/8" diameter all thread bolts were installed using Epcon Ceramic 6 Formual in accordance with
the manufacturer's directions. Prior to installation, the holes were cleaned with compressed air and a
nylon wire brush. Contractor was asked to notify our office when additional servcices are needed.
Inspector:
Number:
Raymond V. Aliperti
ICBO 98554
If you should have any questions regarding this report, please call Raymond Aliperti at (541) 746-9649.
Thank You.
City of Springfield - Bob Barnhart /
St. Vincent de Paul - Lyle Harris
c:
As a mutual protection to clients, the public, and ourselves, all reports are submitted as the confidential
property of clients and are intended for the use of our clients only. No other person or entity may utilize
the report or any portion thereof without our written authorization.
c:\wp51 \reporta\insp\stv58902 .stv