EngIneering. Consulting. Testl"ttAIL y. FIELD REPORT
Date Performed: March 10, 2009 Report Number: 722-80177-61
Client: Lee CDnstructiDn Project Name: A3 - Academy of Arts &
PO BDx 10367 Academics
Eugene, OR 97401 Project Location: 615 Main Street
Springfield, OregDn
P,O, No.: , Permit No.: c.~- 545
Type of Structure: Weather: Cloudy
Type of Inspection: Epoxy AnchDr
Field Observations and Comments
Performed continuous inspectiDn during the installation of 5/8" ali thread epDxied anchor bolts in the foliDwing iocations:5
out of 18 for the canopy in the front of the building. Prior to installation the predrilied hDles were cleaned using a nylon
brush and compressed air. Verified minimum embedment depth of 5 inches. The above iisted epoxy anchors were
instalied using Simpson 'Fast Pac epoxy with ICC #5791. The epDXY anchors were installed in accDrdance with
approved jDb-site plans and manufacturer's direction. Additional Comments: remainder of the bolts will be installed
at a later date. Contractor was asked tD notify our office when additional services are needed. To the best of our
knowledge, the work inspected abDve was in accordance with the building department approved design drawings,
specifications and applicable workmanship erovisions of the International Buildinq Code.
Inspector: Raymond Aliperti, Ice #1017075.88
CCB# 176269
If you have any questions regarding this report, please feel free to contact us at 541-746-9649.
Respectfuliy SUb~lte~
. rofessio eru e l'!1!fitries, Inc.
l \._\lL
David Smith
Branch Manager
c: City of Springfield
Branch Engineering
So/arc Architecture
Professional Underground Service
Springfield School District - John Saraceno
"
THIS REPORT IS PROVIDED FOR THE INFQRMA r/ON OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD
PARTY, BY ANY MEANS. EXCEPT IN FULL. WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED.
Professional Service Industries, Inc. .1040A Shelley 81.. Springfield, OR 97477. Phone 541/746-9649. Fax 541/746'7163
L "~;l Infonnation
,,~. .To Build On .'
Engineering. Consulting. TesfingDAIL Y FIELD REPORT
Date Performed: March 12, 2009 Report Number: : 722-80177-62
Client: Lee Construction Project Name: A3 - Academy of Arts &
PO Box 10367 Academics
Eugene, OR 97401 Project Location: 615 Main Street
'Springfield, Oregon
P.O. No,: Permit No,: C'6~5~S
Type of Structure: Weather: Clear
Type of Inspection: Epoxy Anchor
Field Observations and Comments
Performed continuous inspection during the installation of 5/8" all thread epoxied anchor bolts in the following locations: .
(8) eight for the canopy into existing concrete (sheet E9). Prior to installation the predrilled holes were cleaned using a
nylon brush and compressed air. Verified minimum embedment depth of 5 inches. The above listed epoxy anchors were
installed using Simpson Fast Pac epoxy with ICC #5791. The epoxy anchors were installed in accordance with
approved job-site plans and manufacturer's direction. Contractor was asked to notify our office when additional services
are needed. To the best of our knowledge, the work inspected above was in accordance with the building department
approved design drawings, specifications and applicable workmanship provisions of the International Building Code.
Inspector: Raymond Aliperti, ICC #1017075-88
CCB# 176269
If you have any questions regarding this report, please feel free to contact us at 541-746-9649.
Respectfully Submitted,
[rofeSSiOnaJ s:'tiries, Inc.
b~
Branch Manager
c: City of Springfield
Branch Engineering
So/arc Architecture
Professional Underground Service
Springfield School District - John Saraceno
RECEIVED
APR 0 7 2009
THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLiENT ONL Y. THE REPRODUCTIOI OF THIS REPORT, BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD
PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED.