April 06, 2009
Mr. Jim Thomas
Wildish Building Co.
PO Box 7428
Eugene, Oregon 97401
Project No. 2077183
Report No. E-22679
RE: Slab Moisture Tests
LCAFRC.Complex Phase II
BMUFS Warehouse
3120 Pierce Parkway
Springfield, Oregon
:Building P~rmit No,- COM2007-01740
Dear Mr. Thomas:
As requested, our representative visited the above referenced project on March 31, 2009, to place two (2) moisture
test kits on the floor slab at randomly selected locations. Test locations were prepared and the kits were installed
per manufacturer's instructions. The test kits were left in place for approximately 64.50 hours and were then
collected on April 03, 2009. Results of the tests have been summarized in the table below.
Calcium Chloride Moisture Vapor Emission Test
ASTM F 1869-04
64.5
64.5
Weight
Gain (g\
3.3
3.5
Lbs/per 1000 Sq. Ft
in 24 Hours
Approximate Location
Room 114
Room 160 W
Total
Hours
6.0
6.4
Temperature/Humidity Data
Air Temperature
Relative Humidity
Beginning of Test
Room 114 - 6001 Room 160 W - 580
End of Test
Room 114-610/Room 160W- 550
Room 114 - 54%1 Room 106 W - 65%
Reviewed By:
(1.Y,k-
Michael L. Meyr
Technical Manager
R(C(\,\j(O
t>,VR 1D 1UU~
c:
Barrantine Bates Lee - (e-mail)
kpff Consulting Engineers - (e-mail)
Oregon Military Dept - (e-mail)
City of Springfield MLM:sc
This report andler enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material
evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing &
Inspection, Jnc.'s written authorization.
7fJJNN ComeIIAvenue' Cavallis, Oregoo 97330, phone (541) 757-4698 . fax (541)757-2991
29540 B Airpcxt Rood . Eugene, Oregoo 97402 . pt-rne (541) 684-3849' fax (541) 684.J851
63QfJJCorporaIePlace, Suile2. Bend, 0reg0097701 . phone(541)382~' fax (541) 3824846