HomeMy WebLinkAboutPermit Field Test & Inspection Report 2009-4-6 (~FEl 11:..'mlrw;.lr.'n.IIlI~.IH. Geotechnical & ConsbucIion Services April 06, 2009 Mr. Jim Thomas Wildish Building Co. PO Box 7428 Eugene, Oregon 97401 Project No. 2077183 Report No. E-22679 RE: Slab Moisture Tests LCAFRC.Complex Phase II BMUFS Warehouse 3120 Pierce Parkway Springfield, Oregon :Building P~rmit No,- COM2007-01740 Dear Mr. Thomas: As requested, our representative visited the above referenced project on March 31, 2009, to place two (2) moisture test kits on the floor slab at randomly selected locations. Test locations were prepared and the kits were installed per manufacturer's instructions. The test kits were left in place for approximately 64.50 hours and were then collected on April 03, 2009. Results of the tests have been summarized in the table below. Calcium Chloride Moisture Vapor Emission Test ASTM F 1869-04 64.5 64.5 Weight Gain (g\ 3.3 3.5 Lbs/per 1000 Sq. Ft in 24 Hours Approximate Location Room 114 Room 160 W Total Hours 6.0 6.4 Temperature/Humidity Data Air Temperature Relative Humidity Beginning of Test Room 114 - 6001 Room 160 W - 580 End of Test Room 114-610/Room 160W- 550 Room 114 - 54%1 Room 106 W - 65% Reviewed By: (1.Y,k- Michael L. Meyr Technical Manager R(C(\,\j(O t>,VR 1D 1UU~ c: Barrantine Bates Lee - (e-mail) kpff Consulting Engineers - (e-mail) Oregon Military Dept - (e-mail) City of Springfield MLM:sc This report andler enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Jnc.'s written authorization. 7fJJNN ComeIIAvenue' Cavallis, Oregoo 97330, phone (541) 757-4698 . fax (541)757-2991 29540 B Airpcxt Rood . Eugene, Oregoo 97402 . pt-rne (541) 684-3849' fax (541) 684.J851 63QfJJCorporaIePlace, Suile2. Bend, 0reg0097701 . phone(541)382~' fax (541) 3824846